Official address  Domenico Scarlattilaan 6  ●  1083 HS Amsterdam  ●  The Netherlands 
 
 An agency of the European Union      
 
Address for visits and deliveries  Refer to www.ema.europa.eu/how-to-find-us  
Send us a question Go to www.ema.europa.eu/contact  Telephone +31 (0)88 781 6000 
 
 
© European Medicines Agency, 2022. Reproduction is authorised provided the source is acknowledged. 
27 January 2022 
EMA/117327/2022  
Committee for Medicinal Products for Human Use (CHMP) 
Assessment report 
 
Dasatinib Accordpharma  
International non-proprietary name: dasatinib 
Procedure No. EMEA/H/C/005317/0000 
Note  
Assessment report as adopted by the CHMP with all information of a commercially confidential nature 
deleted. 
 
 
 
 
Assessment report  
 
EMA/117327/2022  
Page 2/30 
 
 
Table of contents 
1. Background information on the procedure .............................................. 6 
1.1. Submission of the dossier ...................................................................................... 6 
1.2. Legal basis, dossier content ................................................................................... 6 
1.3. Information on paediatric requirements................................................................... 7 
1.4. Information relating to orphan market exclusivity ..................................................... 7 
1.4.1. Similarity .......................................................................................................... 7 
1.5. Scientific advice ................................................................................................... 7 
1.6. Steps taken for the assessment of the product ......................................................... 7 
2. Scientific discussion ................................................................................ 8 
2.1. Introduction......................................................................................................... 8 
2.2. Quality aspects .................................................................................................... 9 
2.2.1. Introduction ...................................................................................................... 9 
2.2.2. Active substance ............................................................................................... 9 
2.2.3. Finished medicinal product ................................................................................ 11 
2.2.4. Discussion on chemical, and pharmaceutical aspects ............................................ 16 
2.2.5. Conclusions on the chemical, pharmaceutical and biological aspects ...................... 17 
2.2.6. Recommendation for future quality development ................................................. 17 
2.3. Non-clinical aspects ............................................................................................ 17 
2.3.1. Introduction .................................................................................................... 17 
2.3.2. Ecotoxicity/environmental risk assessment ......................................................... 17 
2.3.3. Discussion on non-clinical aspects...................................................................... 17 
2.3.4. Conclusion on the non-clinical aspects ................................................................ 17 
2.4. Clinical aspects .................................................................................................. 18 
2.4.1. Introduction .................................................................................................... 18 
2.4.2. Clinical pharmacology ...................................................................................... 19 
2.4.3. Discussion on clinical aspects ............................................................................ 25 
2.4.4. Conclusions on clinical aspects .......................................................................... 26 
2.5. Risk Management Plan ........................................................................................ 27 
2.5.1. Safety concerns ............................................................................................... 27 
2.5.2. Pharmacovigilance plan .................................................................................... 27 
2.5.3. Risk minimisation measures .............................................................................. 27 
2.5.4. Conclusion ...................................................................................................... 27 
2.6. Pharmacovigilance .............................................................................................. 28 
2.6.1. Pharmacovigilance system ................................................................................ 28 
2.6.2. Periodic Safety Update Reports submission requirements ..................................... 28 
2.7. Product information ............................................................................................ 28 
2.7.1. User consultation ............................................................................................. 28 
3. Benefit-risk balance .............................................................................. 28 
4. Recommendations ................................................................................. 29 
 
 
 
 
Assessment report  
 
EMA/117327/2022  
Page 3/30 
 
List of abbreviations 
Quality 
API 
 
Active pharmaceutical ingredient 
BCS 
 
Biopharmaceutics classification system 
DS 
 
Drug substance 
DSM 
 
Drug product manufacturer 
DP 
 
Drug product 
DPM 
 
Drug product manufacturer 
DoE 
 
Design of experiments 
EP/ Ph. Eur. 
European pharmacopoeia 
FPS 
 
Finished product specifications 
GMP 
 
Good manufacturing practice 
HDPE 
 
High density polyethylene 
IPA 
 
Isopropyl alcohol 
IPC 
 
In-process control 
LDPE 
 
Low density polyethylene 
LOD 
 
Loss on drying 
LOD 
 
Limit of detection 
LOQ 
 
Limit of quantitation 
NLT 
 
Not less than 
NMT 
 
Not more than 
PDE 
 
Permitted daily exposure 
PP 
 
Polypropylene 
PSD 
 
Particle size distribution 
QbD 
 
Quality by design 
QTPP 
Quality target product profile 
RPM 
Revolutions per minute  
RSD 
Relative standard deviation 
USP/NF  
United States pharmacopoeia / National formula 
XRD 
X Ray diffraction 
 
Clinical 
AE 
Adverse event 
ALL 
Acute lymphoblastic leukaemia 
ANOVA 
Analysis of variance 
AUC 
Area under the plasma concentration-time curve 
BA 
Bioavailability 
BE 
Bioequivalence 
 
Assessment report  
 
EMA/117327/2022  
Page 4/30 
 
cCCyR 
Confirmed complete cytogenetic response 
CHMP 
Committee for medicinal products for human use 
CHR 
Complete haematologic response 
CI 
Confidence interval 
Cmax 
Maximum plasma concentrations observed after dosing 
CML 
Chronic myelogenous leukaemia 
CMR 
Complete molecular response 
CNS 
Central nervous system 
CP 
Chronic phase 
CPM 
Canadian product monograph 
CTC 
Common toxicity criteria 
CV 
Coefficient of variation 
DMR 
Deep molecular response 
ECG 
Electrocardiogram 
EMA 
European Medicines Agency 
EPAR 
European public assessment report 
EU 
European union 
GCP 
Good clinical practice 
GLP 
Good laboratory practice 
GMR 
Geometric mean ratio 
h / hr 
hour 
HPLC 
High pressure liquid chromatography 
HZ 
Hazard ratio 
kg 
Kilogram 
l / L 
Liter 
LC/MS/MS 
Liquid chromatography/mass spectrometry/mass spectrometry 
LLOQ 
Lower limit of quantitation 
ln 
natural logarithmic 
LOQ 
Limit of quantitation 
LSM 
Least squares mean 
MAA 
Marketing authorization application 
MAH 
Marketing authorization holder 
MaHR 
Major haematologic response 
MCyR 
Major cytogenetic response 
MedDRA 
Medical dictionary for regulatory activities 
mg 
Milligram 
mL 
Millilitre 
MMR 
Major molecular response 
NEL 
No evidence of leukaemia 
 
Assessment report  
 
EMA/117327/2022  
Page 5/30 
 
ng 
Nanogram 
OS 
Overall survival 
P 
p-value 
PD 
Pharmacodynamics 
PFS 
Progression-free survival 
PH+ 
Philadelphia chromosome positive 
PK 
Pharmacokinetic 
PO 
Oral 
QOL 
Quality of life 
QTc 
QT interval 
SmPC 
Summary of product characteristics 
TFR 
Treatment-free remission 
TKI 
Tyrosine kinease inhibitor 
Tmax 
Time to reach observed maximum (peak) plasma concentration 
T/R 
Test/reference 
ULN 
Upper limit of normal 
ULOQ 
Upper limit of quantitation 
 
 
 
Assessment report  
 
EMA/117327/2022  
Page 6/30 
 
1.  Background information on the procedure 
1.1.  Submission of the dossier 
The applicant Accord Healthcare S.L.U. submitted on 3 June 2019 an application for marketing 
authorisation to the European Medicines Agency (EMA) for Dasatinib Accordpharma, through the 
centralised procedure under Article 3 (3) of Regulation (EC) No. 726/2004– ‘Generic of a Centrally 
authorised product’. The eligibility to the centralised procedure was agreed upon by the EMA/CHMP on 
28 February 2019. 
The application concerns a generic medicinal product as defined in Article 10(2)(b) of Directive 
2001/83/EC and refers to a reference product, as defined in Article 10 (2)(a) of Directive 2001/83/EC, 
for which a marketing authorisation has been granted in the Union on the basis of a complete dossier 
in accordance with Article 8(3) of Directive 2001/83/EC. 
The applicant applied for the following indication: 
Dasatinib Accordpharma is indicated for the treatment of adult patients with: 
 
newly diagnosed Philadelphia chromosome positive (Ph+) chronic myelogenous leukaemia (CML) 
in the chronic phase. 
 
chronic, accelerated or blast phase CML with resistance or intolerance to prior therapy including 
imatinib. 
 
Ph+ acute lymphoblastic leukaemia (ALL) and lymphoid blast CML with resistance or intolerance 
to prior therapy. 
Dasatinib Accordpharma is indicated for the treatment of paediatric patients with: 
 
newly diagnosed Ph+ CML in chronic phase (Ph+ CML-CP) or Ph+ CML-CP resistant or intolerant 
to prior therapy including imatinib. 
 
newly diagnosed Ph+ ALL in combination with chemotherapy. 
1.2.  Legal basis, dossier content  
The legal basis for this application refers to: 
Generic application (Article 10(1) of Directive No 2001/83/EC. 
The application submitted is composed of administrative information, complete quality data and a 
bioequivalence study with the reference medicinal product Sprycel instead of non-clinical and clinical 
unless justified otherwise  
The chosen reference product is: 
Medicinal product which is or has been authorised in accordance with Union provisions in force for not 
less than 10 years in the EEA:  
• 
Product name, strength, pharmaceutical form: Sprycel, 20, 50, 70, 80, 100, 140 mg, film-coated 
tabled 
• 
Marketing authorisation holder: Bristol-Myers Squibb Pharma EEIG 
• 
Date of authorisation: 20 November 2006 
• 
Marketing authorisation granted by:  
− 
Union 
• 
Marketing authorisation number: EU/1/06/363/001-015 
 
Medicinal product authorised in the Union/Members State where the application is made or European 
reference medicinal product:  
 
Assessment report  
 
EMA/117327/2022  
Page 7/30 
 
• 
Product name, strength, pharmaceutical form: Sprycel, 20, 50, 70, 80, 100, 140 mg, film-coated 
tabled 
• 
Marketing authorisation holder: Bristol-Myers Squibb Pharma EEIG 
• 
Date of authorisation: 20 November 2006 
• 
Marketing authorisation granted by:  
− 
Union 
• 
Marketing authorisation number: EU/1/06/363/001-015 
 
Medicinal product which is or has been authorised in accordance with Union provisions in force and to 
which bioequivalence has been demonstrated by appropriate bioavailability studies:  
• 
Product name, strength, pharmaceutical form: Sprycel, 140 mg, film-coated tabled 
• 
Marketing authorisation holder: Bristol-Myers Squibb Pharma EEIG 
• 
Date of authorisation: 20 November 2006 
• 
Marketing authorisation granted by:  
− 
Union 
• 
Marketing authorisation number: EU/1/06/363/014-015 
• 
Bioavailability study number(s): 2185 
1.3.  Information on paediatric requirements 
Not applicable 
1.4.  Information relating to orphan market exclusivity 
1.4.1.  Similarity 
Pursuant to Article 8 of Regulation (EC) No. 141/2000 and Article 3 of Commission Regulation (EC) No 
847/2000, the applicant did submit a critical report addressing the possible similarity with authorised 
orphan medicinal products. 
1.5.  Scientific advice 
The applicant did not seek Scientific advice from the CHMP. 
1.6.  Steps taken for the assessment of the product 
The Rapporteur and appointed by the CHMP was: 
Rapporteur: 
John Joseph Borg 
The application was received by the EMA on 
3 June 2019 
The procedure started on 
20 June 2019 
The CHMP Rapporteur's first Assessment Report was circulated to all 
CHMP and PRAC members on 
9 September 2019 
The PRAC Rapporteur's first Assessment Report was circulated to all 
PRAC and CHMP members on 
24 September 2019 
The CHMP agreed on the consolidated List of Questions to be sent to the 
applicant during the meeting on 
17 October 2019 
The applicant submitted the responses to the CHMP consolidated List of 
23 April 2020 
 
Assessment report  
 
EMA/117327/2022  
Page 8/30 
 
Questions on 
The CHMP Rapporteur circulated the CHMP and PRAC Rapporteurs Joint 
Assessment Report on the applicant's responses to the List of Questions 
to all CHMP members on 
2 June 2020 
The PRAC agreed on the PRAC Assessment Overview and Advice to CHMP 
during the meeting on 
11 June 2020 
The CHMP agreed on a list of outstanding issues in writing to be sent to 
the applicant on 
25 June 2020 
The applicant submitted the responses to the CHMP consolidated List of 
Outstanding Issues on  
11 December 2020 
The CHMP Rapporteur circulated the CHMP and PRAC Rapporteurs Joint 
Assessment Report on the responses to the List of Outstanding Issues to 
all CHMP and PRAC members on 
10 February 2021 
The CHMP agreed on a 2nd list of outstanding issues in writing to be sent 
to the applicant on 
25 February 2021 
The applicant submitted the responses to the 2nd CHMP consolidated List 
of Outstanding Issues on  
22 December 2021 
The CHMP Rapporteur circulated the CHMP and PRAC Rapporteurs Joint 
Assessment Report on the responses to the 2nd List of Outstanding 
Issues to all CHMP and PRAC members on 
21 January 2022 
The CHMP, in the light of the overall data submitted and the scientific 
discussion within the Committee, issued a positive opinion for granting a 
marketing authorisation to Dasatinib Accordpharma on  
27 January 2022 
The CHMP adopted a report on similarity of Dasatinib Accordpharma with 
Blincyto, Iclusig, Besponsa, Xaluprine and Kymriah on  
27 January 2022 
 
2.  Scientific discussion 
2.1.  Introduction 
This centralised application concerns a generic application according to article 10(1) of Directive 
2001/83/EC for Dasatinib Accordpharma 20/50/70/80/100/140mg film coated tablets. The applicant is 
Accord Healthcare S.L.U.  
The originator product is Sprycel 20/50/70/80/100/140mg film coated tablets marketed by Bristol-Myers 
Squibb Pharma EEIG Ireland and first authorised in the community on 20 November 2006. 
(EU/1/06/363/001-015). The active substance is dasatinib as monohydrate in both products. 
The applicant has applied for all the indications of the reference product. 
One bioequivalence study was conducted in support of this application using the reference Sprycel 140mg 
film coated tablet marketed by Bristol-Myers Squibb Pharma EEIG Ireland and first authorised in the 
community on 20 November 2006 and sourced from Germany. (EU/1/06/363/014-015). 
 
 
Assessment report  
 
EMA/117327/2022  
Page 9/30 
 
Proposed indications: 
Dasatinib Accordpharma is indicated for the treatment of adult patients with: 
 
newly diagnosed Philadelphia chromosome positive (Ph+) chronic myelogenous 
leukaemia (CML) in the chronic phase. 
 
chronic, accelerated or blast phase CML with resistance or intolerance to prior therapy 
including imatinib. 
 
Ph+ acute lymphoblastic leukaemia (ALL) and lymphoid blast CML with resistance or intolerance 
to prior therapy. 
 
Dasatinib Accordpharma is indicated for the treatment of paediatric patients with: 
 
newly diagnosed Ph+ CML in chronic phase (Ph+ CML-CP) or Ph+ CML-CP resistant or 
intolerant to prior therapy including imatinib. 
 
newly diagnosed Ph+ ALL in combination with chemotherapy. 
It is noted that part of the indications of the reference product (shown in bold above) is covered by a 
usage patent. 
2.2.  Quality aspects 
2.2.1.  Introduction  
The finished product is presented as film coated tablets containing 20, 50, 70, 80, 100, and 140 mg of 
dasatinib as active substance.  
Other ingredients are: 
Tablet core: lactose monohydrate, hydroxypropyl cellulose, cellulose, microcrystalline, methacrylic acid 
– methacrylate copolymer (1:2), talc, croscarmellose sodium, and magnesium stearate. 
Film-coating:  hypromellose (E464), titanium dioxide (E171), and medium chain triglycerides. 
The product is available in Alu/Alu blisters (blisters or perforated unit dose blisters) as described in 
section 6.5 of the SmPC.  
2.2.2.  Active substance 
General information 
The chemical name of dasatinib is N-(2-Chloro-6-methylphenyl)-2-[[6-[4-(2-hydroxyethyl)-1-
piperazinyl]-2-methyl-4-pyrimidinyl]amino]-5-thiazole carboxamide corresponding to the molecular 
formula C22H26CIN7O2S. It has a relative molecular weight of 488.02 g/mol and the following structure: 
 
 
Assessment report  
 
EMA/117327/2022  
Page 10/30 
 
Figure: Active substance structure 
The chemical structure of the active substance was elucidated by a combination of NMR spectrum, 
mass spectrum, infrared spectrum, UV spectrum and elemental analysis. 
The active substance is a slightly hygroscopic white to off-white fine crystalline powder which exhibits 
pH dependent aqueous solubility. According to FDA BCS guideline, dasatinib is considered a low solubility 
active substance. 
Optical isomerism is not possible because there is no chiral carbon in the active substance molecule. 
Dasatinib is known to exist in few anhydrous and numerous solvated crystalline forms and in an 
amorphous form, based on literature survey and extensive polymorphism screening studies.  Desired 
anhydrous dasatinib form is consistently obtained by the proposed manufacturing process of the active 
substance. All the other known anhydrous forms and solvates are not likely to be formed in the last 
crystallisation step and in the solvent system used or by storage of the active substance, hence, they 
cannot be present as impurities in the produced desired polymorphic form. 
Manufacture, characterisation and process controls 
An Active Substance Master File (ASMF) procedure was used to provide information on the active 
substance. Detailed information on the manufacturing of the active substance has been provided in the 
restricted part of the ASMF and it was considered satisfactory. 
Dasatinib is synthesised in 2 main stages using commercially available well-defined starting materials 
with acceptable specifications.  
Adequate in-process controls are applied during the synthesis. The specifications and control methods 
for intermediates, starting materials and reagents have been presented.  
The characterisation of the active substance and its impurities are in accordance with the EU guideline 
on chemistry of new active substances. 
Potential and actual impurities were well discussed with regards to their origin and characterised. 
The active substance is packaged in double PE bags with antistatic additive as primary packing, placed 
in multilayer PET/Al/PET/LDPE bag and introduced into cardboard drum. which complies with the EC 
directive 2002/72/EC and EC 10/2011 as amended. 
Specification 
The active substance specification includes tests for description (visual),  identification (IR, HPLC, 
XRD), assay  (HPLC), water (Ph. Eur.), sulphated ash (Ph. Eur.), related substances (GC, HPLC), 
residual solvents (GC, HPLC), and particle size (laser diffraction). 
The specification for dasatinib has been established based on the guidelines of ICH Q3A, ICH 
Q3C, ICH Q3D and ICH Q6A. Dasatinib is not listed in any of the official Pharmacopoeias. 
The limits on related substances are based on analyses of so far manufactured batches of the active 
substance and the ICH guideline Q3A and are considered satisfactory. 
According to the ICH Guideline Q3C for residual solvents, are class 2 and class 3 solvents in 
compliance with the ICH Guideline Q3C. Limits for these solvents are in line with the guideline and also 
tightened according to actual results. 
The analytical methods used have been adequately described and (non-compendial methods) 
appropriately validated in accordance with the ICH guidelines. Satisfactory information regarding the 
reference standards used has been presented. 
 
Assessment report  
 
EMA/117327/2022  
Page 11/30 
 
Batch analysis data (3 commercial scale batches) of the active substance are provided. The results are 
within the specifications and consistent from batch to batch. 
Stability 
Stability data from 4 pilot-scale batches of active substance from the proposed manufacturer stored in 
the intended commercial package for up to 36 months under long term conditions (5±3ºC) and for up 
to 6 months under accelerated conditions (25±2ºC / 60 ±5% RH) according to the ICH guidelines 
were provided.  
The following parameters were tested: appearance, identification, crystal form, water, assay, and 
related substances. The analytical methods used were the same as for release and were stability 
indicating. 
The results so far of long term and accelerated stability studies fully meet the stability specification and 
no changes have been observed in the quality of the active substance. The results fully support a 
retest period. 
The stability results indicate that the active substance manufactured by the proposed supplier is 
sufficiently stable. The stability results justify the proposed retest period of 36 months without storage 
conditions in the proposed container. 
2.2.3.  Finished medicinal product 
2.2.3.1.  Description of the product and Pharmaceutical development 
Description of the product and Pharmaceutical development 
The finished product is presented in film coated tablets containing 20, 50, 70, 80, 100, and 140 mg of 
dasatinib. The tablets are presented as below: 
20 mg: White to off-white, round, 5.6 mm of diameter, coated tablets debossed on one side with 
"DAS" and "20" on the other side. 
 
50 mg: White to off-white, oval, 5.7 x 10.6 mm, coated tablets debossed on one side with "DAS" and 
"50" on the other side. 
 
70 mg: White to off-white, round, 8.7 mm of diameter, coated tablets debossed on one side with 
"DAS" and "70" on the other side. 
 
80 mg: White to off-white, triangle-shaped, 9.9 x 10.2 mm, coated tablets debossed on one side with 
"DAS" and "80" on the other side. 
 
100 mg: White to off-white, oval, 7.1 x 14.5 mm, coated tablets debossed on one side with "DAS" and 
"100" on the other side. 
 
140 mg: White to off-white, round, 11 mm of diameter, coated tablets debossed on one side with 
"DAS" and "140" on the other side. 
 
The aim of the finished product development was to develop a generic dosage form of the reference 
medicinal product Sprycel tablet 20 mg, 50 mg, 70 mg, 80 mg, 100 mg and 140 mg. 
 
Initially, the quality target product profile (QTPP) was defined based on the properties of the active 
substance, characterisation of the reference medicinal product, and consideration of the reference 
product label. Identification of critical quality attributes (CQAs) was based on the impact to patient 
safety and efficacy resulting from failure to meet that quality attributes of the finished product. 
Pharmaceutical development focused on those CQAs that could be impacted by a realistic change to 
 
Assessment report  
 
EMA/117327/2022  
Page 12/30 
 
the finished product formulation or manufacturing process. For the generic medicinal product, these 
CQAs included assay, uniformity of dosage units, residual solvent content, dissolution, and 
degradation. A quality by design (QbD) approach was used to define the formulation and 
manufacturing process and to provide acceptable quality attributes of the generic.  However, no design 
spaces were claimed for the manufacturing process of the finished product. 
 
Reported literature indicates that dasatinib is a poorly soluble, highly permeable Biopharmaceutics 
Classification System (BCS) Class II compound. The reference medicinal product contains dasatinib 
monohydrate, whereas dasatinib anhydrous has been used for the development of the generic medicinal 
product. The data demonstrated that both forms of dasatinib (anhydrous and monohydrate) have highest 
solubility at pH conditions of 4.0 and below. However, in media at pH 3.0-4.0, the anhydrous form was 
shown to be several times more soluble than the monohydrate form. 
These solubility differences lead to different in vitro release profiles from that of the reference medicinal 
product. The formulation has been developed to meet the bio-equivalence criteria. Dasatinib desired 
polymorphic form samples were exposed to different stress conditions and X-ray powder diffraction was 
performed. Preliminary stress testing was carried out on dasatinib anhydrous to study its chemical 
stability, impurity profile and degradation pathway and to facilitate the development of a stability-
indicating method.  Stressed samples were compared to the unstressed sample. The data showed that 
dasatinib anhydrous is labile to UV exposure and oxidative stress treatments, but stable under acidic, 
alkaline, and thermal (both in absence and in presence of high humidity) stresses. XRD data of studies 
on polymorphic stability under stressed conditions showed that dasatinib desired polymorphic form is 
stable under thermal, humidity, pressure and grinding stress conditions. The dasatinib desired 
polymorphic form is also retained after preparing the slurry with water but is converted to IPA (isopropyl 
alcohol) solvate after preparing the slurry with IPA.  
 
The excipients used in the proposed generic product were selected based on those used in the reference 
medicinal product, the formulation development strategy and excipient compatibility studies. Most 
excipients and the quantities used are common in the manufacture of this type of dosage form and are 
considered safe in the proposed concentrations. Binary mixtures of excipients and active substance at 
different ratios were stored under accelerated conditions in HDPE bottles for three months and analysed. 
All results were within specifications; it was therefore concluded that the proposed excipients are 
compatible with the active sustance. All excipients are well known pharmaceutical ingredients and their 
quality is compliant with Ph. Eur standards exept the coating solution which complies with In house 
specifications. There are no novel excipients used in the finished product formulation. The list of 
excipients is included in section 6.1 of the SmPC and in paragraph 2.1.1 of this report. 
 
During stages of development, a formulation using similar excipients and manufacturing process as those 
of the reference product was evaluated. Developed formulation showed that the drug release was 
comparable as that of the reference product. The in-vitro dissolution method developed and validated is 
the QC method that is able to discriminate between good batches and reject the bad ones. The in-vivo 
comparative bioavailability study conducted between the reference medicinal product Sprycel 140 mg 
and the proposed generic medicinal product has been shown to be comparable (Cmax and AUC data). The 
Tmax of the generic medicinal product is also relatively short at 0.75h.  
A major objection (MO) was raised because of a discrepancy in dissolution profiles observed at pH 3 with 
two different batches. The applicant has clarified that the discrepancy in the dissolution profiles at pH 3 
resulted from a batch which had a different composition, particularly with respect to binders (with higher 
amounts of Eudragit), to batches which have the composition proposed for marketing. The MO was 
considered resolved. 
 
Assessment report  
 
EMA/117327/2022  
Page 13/30 
 
The commercial manufacturing process of the finished product consists in premixing, granulation, drying, 
milling, blending, lubrication, compression, and coating. Several batches from different blends of the 
submission and validation batches were analysed and the percentage of each polymorphic form of active 
substance in the finished product was determined based on the XRD patterns of the pure active 
substance. The results of these batches were compared with that of the bio batch. Polymorphic form 
proportions (tested by XRD) were included in both release and shelf life specifications.  
As major objection (MO) on dissolution limit and discriminatory power was raised , the applicant  
proposed dissolution specifications (NLT 75% in 45 mins), it could be observed that the dissolution of  
the batch made with active substance with particles larger than the limits for PSD, would fail the 
dissolution test. The batch made with finer active substance, despite the increased surface area does 
not result in significantly faster dissolution. In both cases (made with finer and larger particles), the 
dissolution profiles fail similarity comparison with the bio batch. Thus, with limits in place for the active 
substance PSD and dissolution, the finished product performance can be ensured. The MO was considered 
to be resolved. 
Comparative bioavailability studies under fasting conditions was performed to assess the bioequivalence 
of formulation of pivotal batch after a single oral dose administration. In the pivotal bioequivalence study, 
the comparison was made between the proposed generic medicinal product and the EU reference 
medicinal product. The results presented showed that the criteria used to assess bioequivalence between 
the generic and reference formulations were fulfilled. The Test to Reference ratio of geometric LS means 
and corresponding 90% confidence interval for Cmax, AUC0-T and AUC0-∞ were all within the 
acceptance range of 80.00 to 125.00%. 
A biowaiver for 20, 50, 70, 80, and 100 mg strengths was applied by the applicant. In support to this 
request, the applicant stated that all strengths are dose proportional; however this was not considered 
to be sufficient justification on its own. In order to demonstrate similarity between the bio batch and all 
the remaining strengths, comparison of dissolution profiles of the highest strength of the bio batch  to 
the dissolution profiles of all the remaining strengths (without surfactant) at pHs 1.2, 4.5 and 6.8 was 
provided and considered satisfactory.  
No data was provided on the proportions of polymorphic forms in the batches used for the request of 
biowaiver, therefore, it could not be confirmed that all batches of all strengths to be manufactured 
routinely will have the same proportions of polymorphic forms as the biobatch. This precluded the 
granting of the biowaiver. Therefore, the CHMP concluded that the biowaiver may only be granted if a 
limit for both anhydrous and solvate polymorphic form proportions is included in the release and shelf 
life specification of all strengths. The applicant agreed to include a limit for both anhydrous and solvate 
polymorphic form proportions in the release and shelf life specification of all strengths and the issue was 
considered solved.  
A risk assessment of the overall finished product manufacturing process was performed to identify the 
high-risk steps that may affect the CQAs of the finished product. Subsequently, the CQAs of 
intermediates from each process step that impact the finished product CQAs were identified.  
For each process step, a risk assessment was conducted to identify potentially high-risk process  
variables which could impact the identified intermediate CQAs and, ultimately, the finished product  
CQAs. These variables were then investigated to better understand the manufacturing process  and to 
develop a control strategy to reduce the risk of a failed batch. 
Several trials were made with active substance having different particle size distribution (PSD) values to 
evaluate the effects of particle size on assay and content uniformity of the finished product. Based on 
the results, there was no significant difference observed among the batch manufactured with different 
 
Assessment report  
 
EMA/117327/2022  
Page 14/30 
 
PSDs of active substance. All results met the specifications. The PSD specification was determined based 
on the range evaluated during process validation. 
Effects of the binders, disintegrant, lubricant, and coating level were studied. As a result of these studies, 
the commercial formulation of the finished product was selected. 
The primary packaging is Alu/Alu blisters (blisters or perforated unit dose blisters). The material complies 
with Ph. Eur. and EC requirements. The choice of the container closure system has been validated by 
stability data and is adequate for the intended use of the product.  
Manufacture of the product and process controls 
The manufacturing process consists of 10 main steps: weighing, sieving, mixing, wet granulation, drying, 
blending, lubrication, compression, film‐coating and packaging. The process is considered to be a 
standard manufacturing process. 
Major steps of the manufacturing process have been validated by a number of studies in tablets blend 
and tablets 20, 50, 70, 80, 100 and 140 mg. The validation was performed on six commercial scale 
batches of dasatinib tablets blend. The two extremes of tablet strength (20 & 140 mg) were validated 
with 3 commercial scale batches each. The 100 mg strength was also validated with 3 batches. The 
validation was performed on one batch for the intermediate strengths: 50, 70 and 80 mg. It has been 
demonstrated that the manufacturing process is capable of producing the finished product of intended 
quality in a reproducible manner, however the CHMP recommended to carry out the leak test for 
packaging integrity and visual checks during commercial phase full scale packaging validation and submit 
the data via a variation. The in-process controls are adequate for this pharmaceutical form.  
Product specification  
The finished product specifications include appropriate tests for this kind of dosage form description 
(visual), identification (HPLC, UV), assay (HPLC), uniformity of dosage unit (HPLC), dissolution (UPLC), 
degradation products (HPLC), residual solvents (GC-HS), water (Ph. Eur.), disintegration (Ph. Eur.), 
polymorphic forms (XRD), and microbial limit tests (Ph. Eur). The specifications are the same for all strengths, 
except the description which include “20”, “50”, “70”, “80”, “100”, and “140” mg depending on the 
strength. 
In the context of reflection paper on the dissolution specification for generic solid oral immediate 
release products with systemic action (Decision tree for the principles for setting specifications based 
on the dissolution results of the bio batch), immediate release is identified as at least 75% (Q) of the 
active substance is dissolved within 45 minutes. The Q derives from the Ph. Eur. (5.17.1) 
recommendation for conventional release dosage forms. Therefore, in line with the reflection paper, 
the applicant was asked as major objection to set a single dissolution specification of NLT 75% in 45 
minutes or else set a specification for more than one time point. The finished product specifications 
limit was amended as requested. 
The potential presence of elemental impurities in the finished product has been assessed on a risk-
based approach in line with the ICH Q3D Guideline for Elemental Impurities. Batch analysis data on 3 
batches using a validated ICP-OES method was provided, demonstrating that each relevant elemental 
impurity does not exceed their PDE, nor their control thresholds. Based on the risk assessment, it can 
be concluded that it is not necessary to include any elemental impurity controls. 
A risk evaluation concerning the presence of nitrosamine impurities in the finished product has been 
requested as major objection considering all suspected and actual root causes in line with the 
“Questions and answers for marketing authorisation holders/applicants on the CHMP Opinion for the 
 
Assessment report  
 
EMA/117327/2022  
Page 15/30 
 
Article 5(3) of Regulation (EC) No 726/2004 referral on nitrosamine impurities in human medicinal 
products” (EMA/409815/2020) and the “Assessment report- Procedure under Article 5(3) of Regulation 
EC (No) 726/2004- Nitrosamine impurities in human medicinal products” (EMA/369136/2020). Based 
on the information provided it is accepted that no risk was identified on the possible presence of 
nitrosamine impurities in the active substance or the related finished product. Therefore, no additional 
control measures are deemed necessary. 
The analytical methods used have been adequately described and appropriately validated in 
accordance with the ICH guidelines. Satisfactory information regarding the reference standards used 
has been presented. 
Batch analysis results are provided for 12 commercial scale batches confirming the consistency of the 
manufacturing process and its ability to manufacture to the intended product specification.  
The finished product is released on the market based on the above release specifications, through 
traditional final product release testing. 
Stability of the product 
Stability data from 12 commercial scale batches of finished product stored for up to 24 months under 
long term conditions (25°C / 60% RH) and for up to 6 months under accelerated conditions (40°C / 75% 
RH) according to the ICH guidelines were provided. The batches of medicinal product are identical to 
those proposed for marketing and were packed in the primary packaging proposed for marketing.  
Samples were tested for description, assay, dissolution, degradation products, water, disintegration, 
polymorphic forms and microbial limit. The analytical procedures used are stability indicating. 
A reduced design has been considered in line with the ICH Q1D guideline. As defined on ICH guidelines, 
topic Q1D: “bracketing is the design of a stability schedule such that only samples on the extremes of 
certain design factors (e.g., strength, container size and/or fill) are tested at all time points as in a full 
design”. A reduced design of stability study, more precisely, bracketing was chosen, seen that the 
formulation of all the strengths is identical and materials of the container closure system are the same 
for all the strengths. The selected approach, regarding the exhibit batches, is to follow in stability three 
batches of each extreme strength and one batch of each intermediate strength. 
 
The long‐term stability studies conducted on the finished product demonstrate that the all parameters 
meet the specifications with the exception of dissolution, for a period of 24 months for all batches under 
stability. Results also conform after 6 months under accelerated stability conditions in the proposed 
container closure system for all batches that are part of the stability program. 
 
Before a shelf life (and associated storage conditions) and a hold time was granted, the applicant was 
asked, as major objection, to address all the observations related to the intra- and inter-batch variability 
in dissolution results of stability batches and provide more long-term stability data. The applicant did not 
provide data of the original stability batches at 36 months but restarted stability studies afresh. The 
applicant was reminded that new time points should be tested at a specification of NLT 75% (Q) at 45 
minutes and stability studies should include tests for proportions of the polymorphic forms in the finished 
product. In line with the CHMP comments, the dissolution limit in the shelf life specifications was 
tightened by the applicant to NLT 75% (Q) in 45 minutes and additional data was generated on new 
batches. Twelve validation batches were, stored in bulk, packaged in blisters and then followed in long-
term and accelerated conditions. All dissolution results performed on the validation batches meet the 
revised dissolution limit NLT 75% (Q) at 45 minutes for a period of 6 months. All these batches were 
stored in bulk for 9 months before being packaged in blisters. All the stability results from the new 
batches met the new established dissolution limits NLT 75% (Q) at 45 minutes.  Given that, for the 
stability studies of the validation batches, the applicant only provided dissolution values, the results of 
the previously submitted batches are being taken into consideration to inform on the other stability 
 
Assessment report  
 
EMA/117327/2022  
Page 16/30 
 
parameters and grant the shelf life. No concerns remained outstanding following the assessment of the 
other stability parameters during previous rounds of this procedure. Since there is currently 6 months’ 
real time stability data available, the shelf life granted in line with ICH Q1E is 12 months. Polymorphic 
form proportions have not been evaluated in stability studies so far but, due to the inclusion of limits for 
such proportions in both the release and shelf-life specifications these are to be included in stability 
studies from this point onwards. 
 
Forced degradation study was carried out on the finished product in solution and power, the effects of 
acid, alkaline, ultraviolet irradiation, thermal and oxidation stresses on the finished product were studied 
and the resulting degradation products were monitored. The forced degradation study of the finished 
product in solution has shown that finished product is sensitive to all stress treatments, forced 
degradation evaluation on powder samples has shown relatively good stability showing a slight 
degradation of the finished product. 
 
In addition, five batches were exposed to light as defined in the ICH Guideline on Photostability Testing 
of New Drug Substances and Products. It has been concluded that the finished product is not sensitive 
to light. 
 
A bulk stability study was performed to propose a bulk holding time period for the bulk tablets. The bulk 
tablets are packed in the designated packaging material for bulk storage. The batches are stored under 
ICH controlled conditions 25°C ± 2°C, 60 % RH ± 5% for 9 months. The testing is performed initially, 
at 3 months, 6 months and 9 months. The results between the bulk tablets and the packaged batches 
of identical stations do not show significant differences. Another bulk stability study was conducted where 
the dissolution specification was NLT 75% (Q) in 45 minutes; tablets were tested initially and after 9 
months and the dissolution specification was met. It is therefore possible to conclude that the product 
can be kept in bulk tablets for a period of 9 months before being packaged in the proposed container 
closure system. 
 
Based on available stability data, the proposed shelf-life of 12 months without any special storage 
conditions as stated in the SmPC (section 6.3) are acceptable. 
Adventitious agents 
It is confirmed that the lactose is produced from milk from healthy animals in the same condition as 
those used to collect milk for human consumption and that the lactose has been prepared without the 
use of ruminant material other than calf rennet according to the Note for Guidance on Minimising the 
Risk of Transmitting Animal Spongiform Encephalopathy Agents Via Human and veterinary medicinal 
products. 
2.2.4.  Discussion on chemical, and pharmaceutical aspects 
Information on development, manufacture and control of the active substance and finished product has 
been presented in a satisfactory manner. The results of tests carried out indicate consistency and 
uniformity of important product quality characteristics, and these in turn lead to the conclusion that 
the product should have a satisfactory and uniform performance in clinical use.  
A number of issues were raised by CHMP as Major Objections (MO). The MOs were related to 
formulation, dissolution of the finished product, presence of polymorphic forms of the active substance 
in the finished product, the strength biowaivers, primary packaging material, dissolution specifications 
of the finished product, risk evaluation of nitrosamines and stability of the finished product. The issues 
were resolved satisfactorily by the applicant as described above.  
At the time of the CHMP opinion, there was a minor unresolved quality issue having no impact on the 
Benefit/Risk ratio of the product, which pertains to carry out the leak test and visual checks during 
 
Assessment report  
 
EMA/117327/2022  
Page 17/30 
 
commercial phase full scale packaging validation and submit the data via a variation. This point is put 
forward and agreed as recommendations for future quality development. 
2.2.5.  Conclusions on the chemical, pharmaceutical and biological aspects  
The quality of this product is considered to be acceptable when used in accordance with the conditions 
defined in the SmPC. Physicochemical and biological aspects relevant to the uniform clinical 
performance of the product have been investigated and are controlled in a satisfactory way. Data has 
been presented to give reassurance on viral/TSE safety. 
2.2.6.  Recommendation for future quality development 
In the context of the obligation of the MAHs to take due account of technical and scientific progress, 
the CHMP recommends the following points for investigation: 
- to carry out the leak test and visual checks during commercial phase full scale packaging validation 
and submit the data via a variation. 
2.3.  Non-clinical aspects 
2.3.1.  Introduction 
A non-clinical overview on the pharmacology, pharmacokinetics and toxicology has been provided, 
which is based on up-to-date and adequate scientific literature. The overview justifies why there is no 
need to generate additional non-clinical pharmacology, pharmacokinetics and toxicology data. The 
non-clinical aspects of the SmPC are in line with the SmPC of the reference product. The impurity 
profile has been discussed and was considered acceptable.  
Therefore, the CHMP agreed that no further non-clinical studies are required.  
2.3.2.  Ecotoxicity/environmental risk assessment 
No Environmental Risk Assessment studies were submitted. This was justified by the applicant as the 
introduction of Dasatinib Accordpharma manufactured by Accord Healthcare S.L.U. is considered 
unlikely to result in any significant increase in the combined sales volumes for all dasatinib containing 
products and the exposure of the environment to the active substance. Thus, the ERA is expected to 
be similar. 
2.3.3.  Discussion on non-clinical aspects 
The Applicant has used isopropyl alcohol to "enhance" the solubility of the dasatinib (presenting better 
dissolution profile). This was to be removed during the manufacturing process. However the applicant 
was asked to discuss the possible formation of a solvate with isopropanol and the possible impact in 
terms of safety. The applicant responded that the proposed release specification for isopropanol 
ensures that the total daily exposure to isopropanol from Dasatinib Accordpharma tablets will be below 
the established PDE of 50 mg/day (Impurities: Guideline for residual solvents Q3C (R6). ICH. 20 
October 2016), thereby representing a safe exposure level when used according to the recommended 
posology of the drug product. The Applicant’s position is considered justified and thus acceptable. 
2.3.4.  Conclusion on the non-clinical aspects 
There are no objections to approval of Dasatinib Accordpharma from a non-clinical point of view. The 
 
Assessment report  
 
EMA/117327/2022  
Page 18/30 
 
non-clinical parts of the SmPC of the generic product are identical to those of the reference product. 
2.4.  Clinical aspects 
2.4.1.  Introduction 
This is an application for film-coated tablets containing dasatinib. To support the marketing 
authorisation application the applicant conducted 1 bioequivalence study with cross-over design under 
fasting conditions. This study was the pivotal study for this application.  
The applicant provided a clinical overview outlining the pharmacokinetics and pharmacodynamics as 
well as efficacy and safety of dasatinib based on published literature. The SmPC is in line with the 
SmPC of the reference product. 
No CHMP scientific advice pertinent to the clinical development was given for this medicinal product.  
For the clinical assessment the Guideline on the Investigation of Bioequivalence 
CPMP/EWP/QWP/1401/98) as well as the Guideline on Bioanalytical method validation 
(EMEA/CHMP/EWP/192217/09) in their current version and Dasatinib product-specific bioequivalence 
guidance (EMA/CHMP/675838/2014) version 1 in its current version (Rev1/2020), are of particular 
relevance. 
GCP aspect 
The Clinical trials were performed in accordance with GCP as claimed by the applicant 
The applicant has provided a statement to the effect that clinical trials conducted outside the 
community were carried out in accordance with the ethical standards of Directive 2001/20/EC. 
Exemption  
The applicant has submitted one fasting bioequivalence study in support of this application, and this 
was performed using the highest strength (140mg film coated) claiming an exemption for the lower 
strengths. To support the strength biowaiver the applicant stated that all strengths have the same 
manufacturer and qualitative composition, are dose proportional and present comparable in vitro 
dissolution profile as the reference product in line with the requirement of the Guideline on the 
Investigation of Bioequivalence CPMP/EWP/QWP/1401/98/Rev.1/ Corr). This is further discussed in the 
quality part of this report.  
The conduct of a single BE study with the highest strength under fasting conditions was in line with 
and the Dasatinib product-specific bioequivalence guidance (EMA/CHMP/675838/2014) version 1 in 
effect when the application was submitted. However during the procedure the guidance was updated 
(EMA/CHMP/675838/2014/Rev1/2020) and a fed study was also requested. During the assessment the 
applicant submitted results of a fed study performed with the 100mg strength using the US reference 
to respond to issues raised. The fed study was not required during the submission and therefore is only 
considered as supportive. 
Tabular overview of clinical studies  
To support the application, the applicant has submitted 1 bioequivalence study. 
 
Assessment report  
 
EMA/117327/2022  
Page 19/30 
 
 
 
2.4.2.  Clinical pharmacology 
2.4.2.1.  Pharmacokinetics 
Study 2185: A Single-Dose, Randomized, Open-Label, Four-Way Fully Replicate, Pivotal, 
Bioequivalence Study of Dasatinib 140 mg Film-coated Tablets (Pharmascience Inc., 
Canada) and SPRYCEL (dasatinib) 140 mg Filmcoated Tablets (Bristol-Myers Squibb Pharma 
EEIG, UK) in Healthy Male Volunteers under Fasting Conditions 
Methods 
• 
Study design  
The applicant has submitted a comparative bioequivalence study protocol number 2185 version number 
01 dated 20 October 2017 which was approved by the Optimum Ethics Review Board, Ontario, Canada 
on 25 October 2017.  
This was a randomized, balanced, open label, single dose, four way fully replicate, two sequence, two 
treatment,  comparative oral bioavailability study to establish comparative bioequivalence of Dasatinib 
140 mg film coated tablets (Pharmascience Inc, Canada) and Sprycel (dasatinib) 140 mg film coated 
tablets (MAH: Bristol-Myers Squibb Pharma EEIG, UK) in 60 healthy, adult male subjects under fasting 
conditions. The objective of the study was to compare the rate and extent of absorption of both products 
and to monitor the adverse events to ensure the safety and tolerability of a single dose of Dasatinib 140 
mg.  
The study centre was BioPharma Services Inc Canada. The studies were conducted between 29 
November 2017 and 13 February 2018 and bioanalysis was performed between 02 January 2018 and 11 
January 2018.  
Subjects who met the eligibility criteria were randomly assigned to receive the study drugs according to 
one of the two dosing sequences A-B-A-B or B-A-B-A. A total of 30 subjects were planned to receive 
treatment sequence A-B-A-B and 30 subjects were planned to receive sequence B-A-B-A.  
Subjects randomized to the A-B-A-B sequence received the Test product (Treatment A: Dasatinib 140 
mg tablets) in period 1 and period 3, and then following a 7 days washout period, received the Reference 
product (Treatment B: Sprycel 140 mg film-coated tablets) in period 2 and period 4. Subjects randomized 
to the B-A-B-A sequence received the Reference product (Treatment B) in period 1 and period 3, and 
 
Assessment report  
 
EMA/117327/2022  
Page 20/30 
 
then following a minimum 7 days washout period, received the Test product (Treatment A) in period 2 
and period 4. The washout period of at least 7 days was estimated to be adequate in avoiding carry-over 
effects of the preceding treatments. 
Subjects were dosed consecutively according to the randomization scheme beginning at 08:01 on: 
November 30, 2017 for Period 1, December 07, 2017 for Period 2, December 14, 2017 for Period 3, and 
December 21, 2017 for Period 4. 
Based on the randomised schedule and following an overnight fast of at least 10 hours in both periods 
each volunteer received their assigned formulation with 240 ± 3 mL of ambient temperature water at 
their scheduled timepoint. Subjects were instructed not to touch, chew, bite or break the study drug. No 
fluid was allowed from one hour before dosing until one hour after dosing. Subjects were dosed while in 
sitting posture and were instructed to remain seated in an upright position for the first 4 hours following 
drug administration. 
Blood samples were taken at the following time points: pre-dose and at 0.17, 0.25, 0.5, 0.75, 1, 1.25, 
1.5, 1.75, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, and 24 hours after dosing. Blood sampling time 
adjustments are presented in the dossier. 
• 
Test and reference products  
Table 1: Test and Reference Product information  
 
Product charachteristics 
Test Product 
Reference Product 
Name  
Dasatinib 
Sprycel 
Strength  
140 mg 
140 mg 
Dosage form 
Film coated tablets 
Film coated tablets 
Batch number 
P-2631 
AAH3634 
Batch Size (biobatch) 
Complied with the requirement 
of the BE guidelines 
 
Measured content (% labelled 
claim) 
97.2% 
96.6% 
Expiry date (retest date) 
Retest date: 12-2017 
Expiry date: 03-2018 
Member state where the 
reference prduct was purchased 
 
Germany 
The product was used in the 
following trials 
2185 
2185 
 
• 
Population(s) studied 
60 healthy adult male human subjects were enrolled as per the protocol. The study started with 60 
subjects and 56 completed the study. 
Main inclusion criteria: 
Subjects met the following inclusion criteria within 30 days prior to Period 1 dosing: 
1. Healthy, non-smoking (for at least 6 months prior to first study drug administration), male volunteers, 
18 years of age and older. 
2. BMI between 18.5 and 30.0 kg/m², inclusive. 
 
Assessment report  
 
EMA/117327/2022  
Page 21/30 
 
3. Healthy, according to the medical history, ECG, vital signs, laboratory results and physical examination 
as determined by the PI/Sub-Investigator. 
4. QTc interval < 430 milliseconds, unless deemed otherwise by the PI/Sub-Investigator. 
5. PR interval between 120 and 200 milliseconds, inclusive and QRS interval <120 milliseconds, unless 
deemed otherwise by the PI/Sub-Investigator. 
6. Systolic blood pressure between 95-140 mmHg, inclusive, and diastolic blood pressure between 55-
90 mmHg, inclusive, and heart rate between 50-100 bpm, inclusive, unless deemed otherwise by the 
PI/Sub-Investigator. 
7. Clinical laboratory values within BPSI’s most recent acceptable laboratory test range, unless values 
are deemed by the PI/Sub-Investigator as “Not Clinically Significant”. 
8. Ability to comprehend and be informed of the nature of the study, as assessed by BPSI staff. Capable 
of giving written informed consent prior to receiving any study medication. Able to communicate 
effectively with clinic staff. 
9. Ability to fast for at least 14 hours and consume standard meals. 
10. Availability to volunteer for the entire study duration and willing to adhere to all protocol 
requirements. 
11. Agreed not to have a tattoo or body piercing until the end of the study. 
12. Agreed not to drive or operate heavy machinery if feeling dizzy or drowsy following study drug 
administration until full mental alertness was regained. 
13. Agreed not to donate sperm during the study and until 90 days after the last study drug 
administration. 
14. Men who were able to impregnate a female agreed to use medically acceptable methods of 
contraception during the study and for 90 days after the end of the study. 
Medically acceptable methods of contraception include using a condom with spermicide with a female 
partner of child-bearing potential who was using oral contraceptives, hormonal patch, implant or 
injection, intrauterine device, or diaphragm with spermicide. Complete abstinence alone could be used 
as a method of contraception. 
Participant unable to procreate; defined as surgically sterile (i.e., has undergone a bi-lateral vasectomy 
at least 6 months prior to the first administration of the study drug). 
If a subject’s partner became pregnant during his participation in the study and for 90 days after he had 
completed his last study drug administration, he must have informed BPSI staff immediately. 
 
Protocol deviations:  
Period 1:  
27 samples (15 for the test and 12 for the reference) were aliquoted with 1 minute 
delay after centrifugation. 
Period 2:  
3 subjects checked in late resulting in less than advised confinement time.  
Period 4:  
1 subject checked in late resulting in less than advised confinement time 
2 samples (1 for the test and 1 for the reference) were centrifuged with 2 minutes 
delay after collection). 
 
Assessment report  
 
EMA/117327/2022  
Page 22/30 
 
Drop outs:  
Two Subjects withdrew voluntarily from the study and two subjects were removed by the Investigator 
due to testing positive for drugs of abuse.  
 
 
• 
Analytical methods 
Analysis of Dasatinib was performed using test method RDPM257. This Ultra Performance Liquid 
Chromatography Method with Tandem mass spectrometry method involved the extraction of Dasatinib-
d8 (internal standard) from human plasma. Throughout sample collection and following centrifugation, 
the samples were maintained in an ice-bath until stored in the freezer. All plasma samples were shipped 
by courier in dry ice, and the first set of samples were received frozen and in good condition by the 
bioanalytical facility  on 28 December 2017.  
Total long-term plasma stability has been provided for 100 days at nominal temperature of -20°C and 
28 days at nominal temperature of -70°C which covers the 42 days at -20°C (November 30, 2017 –
January 11, 2018) from the first collection date to last extraction date. 
4618 blood samples were expected and 4618 were received. All the samples received were analysed.  
Bioanalytical report: The bioanalytical report dated 2 March 2018 was submitted with 20% of the 
subject chromatograms presented as well as the method SOP. Dasatinib d8 was used as an internal 
standard (IS) and was sourced from TLC Pharmaceutical Standards. Certificates of analysis for the test 
and reference drug products as well as for the drug standards used for Dasatinib and the internal 
standard dasatinib –d8 have been provided and are deemed acceptable.  
The inter day coefficient of variation (%CV) for the quality control samples at concentrations of 3.00 
ng/mL (QC A), 100.00 ng/mL (QC B), 160.00 ng/mL (QC C) and 40.00 ng/mL (QC D) were 3.6%, 2.4%, 
2.8% and 2.7% respectively and the inter day % Bias were 0.2%, 0.0%, 1.0% and 0.7%, respectively. 
Calibration range: 1.00ng/ml to 200.00 ng/ml (8 point curve) 
Reanalysis: 101 samples were re-assayed (2.2%). There were 86 re-assays for COACR (concentration 
outside accepted calibrated range) and 15 re-assays for LS (lost sample). The reason for their repeats 
was documented and presented.  
Incurred Sample Reanalysis: 288 samples were identified for incurred sample reanalysis however 
they did pass the set limits:  The total of 100.00% ISR samples were found to be within ±20% of the 
mean of their original assay values.  
Validation of the test method: The method has been validated (RDPV257) in February 2017. The 
following parameters were addressed; selectivity and specificity of Dasatinib and the internal standard 
(IS), calibration curve (linearity), carryover test, matrix effect precision and accuracy, LLOQ and ULOQ, 
recovery of both the analyte and the internal standard, intra and inter assay precision and accuracy, 
dilution integrity accuracy and precision, freeze-thaw (4 cycles), long term stability at -20°C and -70°C 
, lipemic effect precision and accuracy, haemolysis effect accuracy and precision, concomitant medication 
interference (acetaminophen, caffeine, chlorpheniramine, ibuprofen, naproxen, pseudoephedrine) and 
metabolite interference (metabolites 4’-hydroxy dasatinib and dasatinib N-oxide), short term stability 
(bench top) at room temperature, processed sample stability at 4°C, stock solution stability of dasatinib 
and internal standard at -20°C and at room temperature, Internal standard working solution stability at 
4°C and at room temperature. Each parameter has been assessed and the limits are justified. This is 
deemed acceptable. 
Pharmacokinetic variables 
 
Assessment report  
 
EMA/117327/2022  
Page 23/30 
 
Primary parameters:  AUC0-t, AUC0-inf and Cmax  
Secondary parameters: Tmax, Residual area, Elimination rate constant, T1/2 
• 
Bioequivalence criteria; Bioequivalence was concluded if the 90% confidence interval of 
geometric mean of Cmax, AUC0-t and AUC0-inf between test and reference products fall 
within the range of 80.00 % to 125.00 % for Dasatinib. 
• 
Statistical methods 
Descriptive statistics (min, max, median, mean, standard deviation and coefficient of variation) of all PK 
parameters were to be provided for dasatinib for the Test and Reference products. 
The within-subject standard deviation (SWR and SWT) of the test and the reference products was to be 
determined for the ln-transformed pharmacokinetic parameters AUCt, AUCinf and Cmax. 
The inter-subject and intra-subject CV were to be calculated for the ln-transformed pharmacokinetic 
parameters AUCt, AUCinf and Cmax. 
Average bioequivalence was to be used to determine bioequivalence first. If bioequivalence was not met 
for Cmax, scaled-average-bioequivalence could have been used if both of the following conditions are 
met: 
• The point estimate of the geometric mean ratio was within the 80.00- 125.00% range; 
• The Reference-to-Reference within-subject coefficient of variation (CV) was > 30%, and was not the 
result of outliers 
Average Bioequivalence 
ANOVA including sequence, subjects nested within sequence, period and treatment was to be performed 
on the ln-transformed data for AUCt, AUCinf and Cmax. 
The 90% CI of the Test/Reference ratios of geometric means for AUCt, AUCinf and Cmax was to be 
calculated based on the LSMEANS and ESTIMATE of the ANOVA. 
Results 
 
 
Assessment report  
 
EMA/117327/2022  
Page 24/30 
 
Table 3 
Statistical analysis for Dasatinib 140mg (fasting) (ln-transformed values) 
 
Outliers 
Upon review of the concentration data, it was noted that subject 34 demonstrated concentration values 
that were below the limit of quantitation (BLQ) for periods 1, 3, and 4, while having demonstrated 
measurable concentration values for period 2 only. Since subject 34 does not fulfil the PK data set criteria 
defined in section 11.1 of the protocol, which states that subjects should have measurable concentration 
data from at least two periods, data from subject 34 was not included in the PK stats analysis and is 
instead presented separately. 
Initially, data from all 56 subjects who completed, and demonstrated measurable concentration values 
for, at least 2 periods of the study were included in the PK stats analysis, as per protocol. 
It was noted that subject 60 demonstrated very low concentration values for both reference arms, 
where their individual AUC values for the reference were less than 5% of the geometric mean AUC value 
of the reference product, which was calculated upon exclusion of their data. As per protocol, the data 
obtained from the reference arms for subject 60 were to be excluded from PK stats analysis. However, 
since both sets of reference data were excluded, the entirety of concentration data obtained from subject 
60 were omitted from PK stats analysis, since a test/reference comparison was no longer possible. Data 
from 55 subjects were included in the final PK stats analysis.  
Subject 52 and 54 demonstrated very low concentration values in period 2, after both having been 
dosed with the reference. Both subjects showed individual AUC values for the reference during period 2 
that were less than 5% of the geometric mean AUC value of the reference product, which was calculated 
upon exclusion of their data. Period 2 data was excluded from PK stats analysis for subjects 52 and 54. 
Table 4: Pharmacokinetic parameters for Dasatinib 140mg (fasting n=56) (non-transformed values) 
including subject 60 and period 2 for subjects 52 and 54 
 
 
• 
Safety data 
There were 46 adverse events involving 20 subjects in this study. No serious AEs were reported during 
the conduct of this study.  
There were 23 AEs associated with 15 subjects who received Treatment A (test). There were three 
instances of diarrhoea after administration with Treatment A in this study. 
 
Assessment report  
 
EMA/117327/2022  
Page 25/30 
 
There were 23 AEs associated with 12 subjects who received Treatment B (reference). There were three 
instances of diarrhoea and one instance of vomiting after administration with Treatment B in this study. 
All subjects underwent urine tests for drugs of abuse, cotinine, and an alcohol test at check-in for each 
study period. All test results at check-in for drugs of abuse, cotinine, and breath alcohol were negative 
with the exception of test results for subjects 36 and 51 who were positive to DOA test at period 2 check-
in. Both subjects were dismissed from the study due to this positive test. 
In addition, a complete blood count (CBC) was performed on all subjects at each period check-in. All test 
results at check-in for complete blood count were within normal range or deemed Not Clinically 
Significant by the Investigator. 
The clinical laboratory tests (hematology, serum chemistry and urinalysis) were repeated prior to 
discharge at the end of the study or after termination of subjects from the study. There were no 
screening, on study or post-study laboratory results outside of normal range that were deemed 
Clinically Significant by the Investigator. 
2.4.2.2.  Pharmacodynamics 
No new pharmacodynamic studies were presented and no such studies are required for this 
application.  
2.4.2.3.  Additional data 
2.4.3.  Discussion on clinical aspects 
During the assessment a number of issues were raised. The applicant was asked to justify a number of 
outliers observed and discuss the issue in the context of the known issues of variability in dasatinib 
exposure relating to the brand leader. The applicant has addressed the subjects mentioned in the major 
objection at d120 and all outliers have since been justified. On another aspect the applicant was asked 
to update the dossier submitting a request for biowaiver of the additional requested strengths. The 
biowaiver request was submitted and it is extensively discussed in the quality part of this report. 
The results discussed above show that the PK parameters of the bioequivalence study pass the 
requirements of the guideline on the Investigation of Bioequivalence where the applicant states that the 
90% confidence intervals calculated for the primary parameters Cmax and AUC0-t for Dasatinib fall within 
the 80.00 – 125.00% acceptance range after single dose administration under fasting conditions. The 
submission of a single BE study in the fasted state was in line with the requirements of the Product 
specific BE guidance for dasatinib at the time the application was submitted. 
It is noted that the Product specific BE guidance for dasatinib has since been revised. It specifically 
mentions the issue of outliers (these were the cause of concern in the major objection raised at day 
120). In fact the guideline states that “Some subjects may randomly exhibit low concentrations of 
dasatinib when taking dasatinib products in the fasted state. Therefore, these products are considered 
with specific formulation characteristics and, consequently, bioequivalence should be evaluated under 
fasting and fed conditions” 
Hence a major objection was raised by the CHMP and the applicant was asked to discuss the issue of 
variabilitiy in dasatinib exposure in that some subjects which may randomly exhibit low concentrations 
of dasatanib when taking dasatinib products in the fasted state. As these products are considered with 
specific formulation characteristics and bioequivalence should be evaluated under fasting and fed 
conditions the applicant was asked to address the lack of a fed study and to assess  the impact of food 
on the variability of this product. The Applicant was requested to justify providing a fasting study only 
 
Assessment report  
 
EMA/117327/2022  
Page 26/30 
 
taking account of the Guideline on the investigation of Bioequivalence where “subjects with very low 
plasma concentrations may be excluded if AUC is less than 5% of reference medicinal product geometric 
mean AUC.”  
The applicant submitted a fed study on the 100 mg strength compared to the US innovator product for 
dasatinib using parameters approved by FDA for variable drugs. The results of Dasatinib fed study have 
been re-analyzed against EMA bioequivalence criteria and statistical method. The test product Dasatinib 
100 mg Film-Coated Tablets demonstrated a comparable extent of absorption of dasatinib to the 
reference product SPRYCEL (dasatinib) 100 mg Film-Coated Tablets with a test/reference (T/R) 
geometric mean ratios (GMR) of approximately 97% for AUCt, with the corresponding 90% CI contained 
within the EMA-acceptance range 80.00% - 125.00%. The test product also demonstrated a comparable 
rate of absorption of dasatinib to the reference product with a T/R GMR of approximately 86% for Cmax 
within the EMA-acceptance range 80.00% - 125.00% and corresponding 90% CI contained within the 
EMA-widening acceptance range 78.25 –  127.80%. In parallel, the applicant performed a 
physicochemical comparison of the EU reference and US reference product Sprycel comparing also their 
dissolution profiles illustrating their similarity.  
The fed study falls within the acceptance range for 90%CI for the AUC but not for the Cmax. The 
geometric mean ratios are 97% for AUCt and 85% for Cmax. For Cmax the 90% CI are contained within 
the EMA-widened acceptance range 78.25 – 127.80% for variable drugs. The applicant seems to be using 
the FDA reference scaled and unscaled bioequivalence system for variable drugs. The applicant concluded 
that in line with the protocol and based on the results of the reference scaled and unscaled approach, 
BE is demonstrated under fed conditions.  
The study is considered to be supportive of the argument requested in the major objection but not valid 
for the EU since the reference product used is sourced from the US market and since it is not performed 
on the highest and most sensitive strength. The major objection raised due to the change of EU guidance 
after submission was therefore considered to be resolved. 
In terms of safety a total of 22 mild and 1 moderate AEs were experienced by the subjects after taking 
the Test product. A total of 21 mild and 2 moderate AEs were experienced by the subjects after taking 
the Reference product. No AEs associated with clinical laboratory tests were experienced by the subjects 
at post-study. No serious adverse events were reported during the conduct of this study. The two 
products exhibited a similar safety profile. 
2.4.4.  Conclusions on clinical aspects 
Based on the presented bioequivalence study 2185 Dasatinib 140mg film coated tablets is considered 
bioequivalent with Sprycel 140mg film coated tablets (dasatinib) in normal, healthy, male volunteers 
under fasting conditions. This application was submitted prior to the publication of the updated product 
specific bioequivalence guideline for dasatinib hence a fasting study is appropriate. A supportive fed 
study was also submitted however this cannot be considered as an extra study since the reference 
product used is that of the US and the study was done on the 100mg strength (which is not the highest 
strength in the range proposed.) 
The results of study 2185 with 140mg formulation CAN be extrapolated to other strengths 20mg, 50mg, 
70mg, 80mg, and 100mg, according to conditions in the relevant Guidelines. Kindly refer to the quality 
sections for further information. 
The product is approvable from a clinical point of view and all issues have been resolved. 
 
Assessment report  
 
EMA/117327/2022  
Page 27/30 
 
2.5.  Risk Management Plan 
2.5.1.  Safety concerns  
Table SVIII.1: Summary of safety concerns 
Summary of safety concerns 
Important identified risks 
Myelosuppression 
Fluid retention 
Bleeding related events 
QT prolongation 
Pulmonary Arterial Hypertension (PAH) 
Pregnancy related malformative or foeto/ neonatal toxicity 
Important potential risks 
Severe hepatotoxicities 
Direct cardiotoxic effects (e.g., Cardiomyopathy) 
Growth and development disorders and bone mineral 
metabolism disorders in the paediatric population 
Toxic skin reactions 
CYP3A4 drug interactions 
HBV reactivation 
Nephrotic syndrome 
Missing information 
Carcinogenicity 
Paediatric data: Children < 1 year of age 
Reproductive and lactation data 
 
2.5.2.  Pharmacovigilance plan  
No additional pharmacovigilance activities. 
2.5.3.  Risk minimisation measures 
None. 
2.5.4.  Conclusion 
The CHMP and PRAC considered that the risk management plan version 1.1 is acceptable.  
In addition, the following minor revisions are recommended to be taken into account with the next RMP 
update:  
In addition, minor revisions were recommended to be taken into account with the next RMP update: 
 
Assessment report  
 
EMA/117327/2022  
Page 28/30 
 
Part III: Pharmacovigilance plan 
- 
Other targeted follow-up measures: The Applicant is encouraged to implement targeted follow-
up measures to ensure complete data on the paediatric cases and cases of relevant serious 
cardiac events. 
Annex 4 
- 
Pulmonary Arterial Hypertension (PAH) questionnaire: The Applicant should ensure that 
information on patient ID, product name and batch number is obtained. The Applicant should 
consider collecting information on additional laboratory parameters performed in relation to the 
PAH. 
2.6.  Pharmacovigilance  
2.6.1.  Pharmacovigilance system 
The CHMP considered that the pharmacovigilance system summary submitted by the applicant fulfils the 
requirements of Article 8(3) of Directive 2001/83/EC. 
2.6.2.  Periodic Safety Update Reports submission requirements 
The requirements for submission of periodic safety update reports for this medicinal product are set out 
in the list of Union reference dates (EURD list) provided for under Article 107c(7) of Directive 2001/83/EC 
and any subsequent updates published on the European medicines web-portal. 
2.7.  Product information 
2.7.1.  User consultation 
The results of the user consultation with target patient groups on the package leaflet submitted by the 
applicant show that the package leaflet meets the criteria for readability as set out in the Guideline on 
the readability of the label and package leaflet of medicinal products for human use. 
3.  Benefit-risk balance  
This application concerns a generic version of dasatinib film coated tablets. The reference product 
Sprycel is indicated for  
the treatment of adult patients with: 
 
newly diagnosed Philadelphia chromosome positive (Ph+) chronic myelogenous leukaemia (CML) 
in the chronic phase. 
 
chronic, accelerated or blast phase CML with resistance or intolerance to prior therapy including 
imatinib. 
 
Ph+ acute lymphoblastic leukaemia (ALL) and lymphoid blast CML with resistance or intolerance 
to prior therapy. 
and 
the treatment of paediatric patients with: 
 
newly diagnosed Ph+ CML in chronic phase (Ph+ CML-CP) or Ph+ CML-CP resistant or intolerant 
to prior therapy including imatinib. 
 
newly diagnosed Ph+ ALL in combination with chemotherapy. 
 
Assessment report  
 
EMA/117327/2022  
Page 29/30 
 
 
No nonclinical studies have been provided for this application but an adequate summary of the 
available nonclinical information for the active substance was presented and considered sufficient. 
From a clinical perspective, this application does not contain new data on the pharmacokinetics and 
pharmacodynamics as well as the efficacy and safety of the active substance; the applicant’s clinical 
overview on these clinical aspects based on information from published literature was considered 
sufficient. 
The bioequivalence study forms the pivotal basis with a randomised, two-period, two-treatment 
crossover design. The study design was considered adequate to evaluate the bioequivalence of this 
formulation and was in line with the respective European requirements. Choice of dose, sampling 
points, overall sampling time as well as wash-out period were adequate. The analytical method was 
validated. Pharmacokinetic and statistical methods applied were adequate. 
The test formulation of Dasatinib Accordpharma met the protocol-defined criteria for bioequivalence 
when compared with the Sprycel. The point estimates and their 90% confidence intervals for the 
parameters AUC0-t, AUC0-72h, and Cmax were all contained within the protocol-defined acceptance 
range of [range, e.g. 80.00 to 125.00%]. Bioequivalence of the two formulations was demonstrated. 
A benefit/risk ratio comparable to the reference product can therefore be concluded. 
The CHMP, having considered the data submitted in the application and available on the chosen 
reference medicinal product, is of the opinion that no additional risk minimisation activities are 
required beyond those included in the product information. 
4.  Recommendations 
Similarity with authorised orphan medicinal products 
The CHMP by consensus is of the opinion that Dasatinib Accordpharma is not similar to Blincyto, 
Iclusig, Besponsa, Xaluprine and Kymriah within the meaning of Article 3 of Commission Regulation 
(EC) No. 847/2000.  
Outcome 
Based on the CHMP review of data on quality, safety and efficacy, the CHMP considers by consensus 
that the benefit-risk balance of Dasatinib Accordpharma is favourable in the following indication: 
Dasatinib Accordpharma is indicated for the treatment of adult patients with: 
 
newly diagnosed Philadelphia chromosome positive (Ph+) chronic myelogenous leukaemia (CML) 
in the chronic phase. 
 
chronic, accelerated or blast phase CML with resistance or intolerance to prior therapy including 
imatinib. 
 
Ph+ acute lymphoblastic leukaemia (ALL) and lymphoid blast CML with resistance or intolerance 
to prior therapy. 
 
Dasatinib Accordpharma is indicated for the treatment of paediatric patients with: 
 
newly diagnosed Ph+ CML in chronic phase (Ph+ CML-CP) or Ph+ CML-CP resistant or intolerant 
to prior therapy including imatinib. 
newly diagnosed Ph+ ALL in combination with chemotherapy. 
 
Assessment report  
 
EMA/117327/2022  
Page 30/30 
 
The CHMP therefore recommends the granting of the marketing authorisation subject to the following 
conditions: 
Conditions or restrictions regarding supply and use 
Medicinal product subject to restricted medical prescription (see Annex I: Summary of Product 
Characteristics, section 4.2). 
Other conditions and requirements of the marketing authorisation  
• 
Periodic Safety Update Reports  
The requirements for submission of periodic safety update reports for this medicinal product are set 
out in the list of Union reference dates (EURD list) provided for under Article 107c(7) of Directive 
2001/83/EC and any subsequent updates published on the European medicines web-portal. 
Conditions or restrictions with regard to the safe and effective use of the medicinal product 
• 
Risk Management Plan (RMP) 
The marketing authorisation holder (MAH) shall perform the required pharmacovigilance activities and 
interventions detailed in the agreed RMP presented in Module 1.8.2 of the marketing authorisation and 
any agreed subsequent updates of the RMP. 
An updated RMP should be submitted: 
• 
At the request of the European Medicines Agency; 
• 
Whenever the risk management system is modified, especially as the result of new 
information being received that may lead to a significant change to the benefit/risk profile or 
as the result of an important (pharmacovigilance or risk minimisation) milestone being 