1. What is a Normal Operating Range (NOR) and how should
NORs be presented in the marketing authorisation dossier? 
Answer: 
NOR is not an established ICH term. 
The NOR describes a region around the target operating conditions that contain common operational 
variability (variability that can’t always be controlled).  
A NOR can be established for several process parameters of the same process step, with the 
understanding that the NOR does not represent deliberate adaptation of the process, and that the NOR 
does not cover a parameter range that affects the quality of the process output. Otherwise, a PAR or a 
multivariate Design space should be established. 
The use of NORs alone is not intended to introduce flexibility in the conditions for manufacturing but to 
better quantify the actual uncontrollable operational variability of process parameters. NORs should 
therefore be presented in marketing authorisations as what is practically achievable. 
2. What is a Proven Acceptable Range (PAR) and how should
PARs be justified and presented in the marketing 
authorisation dossier? 
Answer: 
The PAR is defined as a characterized range of a process parameter for which operation within this 
range, while keeping other parameters constant, will result in producing a material meeting relevant 
quality criteria (ICH Q8 R2).  
A PAR allows deliberate change in one parameter without changing the others outside their NOR/ 
target. PARs could be presented in the description of the manufacturing process of the drug substance 
and/or the drug product (in S.2.2 or P.3.3 of the Module 3, respectively) as ranges.  
 
 
Questions and answers: Improving the understanding of NORs, PARs, DSp and normal variability of 
process parameters 
EMA/604040/2016EMA/CHMP/CVMP/QWP/354895/2017 
 
 
EMA/CHMP/CVMP/QWP/354895/2017 
Page 2/4 
 
PARs for single parameters are proposed by the applicant and are subject to regulatory assessment 
and approval. 
The PAR should be adequately justified regardless of whether the process parameter is considered a 
critical process parameter (ICH Q8 R2) or not.  
Where interaction effects between different parameters exist and the acceptable range for one process 
parameter depends on the setting of another parameter, the parameters should be included in a 
Design Space. Alternatively, a PAR can be defined for only one of the parameters in the process 
description, and other process parameters will be limited to target operating condition or NOR.  
PARs can initially be established at a smaller scale than the commercial scale. If so, the applicant 
should ensure that the PAR is scale independent and applicable across alternative manufacturing sites, 
if relevant. Verification of PAR at commercial scale could be included in a post-approval verification 
protocol if appropriate. 
Working within the approved PAR is not considered as a change to the marketing authorisation dossier. 
Changes to the target value within the registered PAR can be managed under the company’s 
Pharmaceutical Quality System without regulatory action. Consequently, there is no specific need to 
include a target set point within the registered PAR, but if included no variation will be required when 
changed. Any unexpected result should be reported forthwith to the competent authorities. Movement 
out of the PAR is considered to be a change and will initiate a regulatory post approval change process. 
Considerations for development (S.2.6/ P.2.3 of Module 3): Several PARs can be presented and 
investigated as part of the process understanding and development. 
3.  What is a Design Space (DSp) and how should design 
spaces be justified and presented in the marketing 
authorisation dossier? 
Answer: 
The design space is defined by the multidimensional combination and interaction of input variables 
(e.g., material attributes) and process parameters that have been demonstrated to provide assurance 
of quality. Working within the approved design space is not considered as a change. Movement out of 
the design space is considered to be a change and would normally initiate a regulatory post approval 
change process. Design space is proposed by the applicant and is subject to regulatory assessment 
and approval (ICH Q8 R2). 
A design space (DSp) can pertain to an isolated process step, or it can cover parameters of several 
process steps. 
A DSp can be supported by suitable in-process controls, or output material quality can be assured by 
working within the DSp ranges alone. 
A DSp can be restricted by ranges of process parameters only, input material attributes only, or a 
combination of process parameters and input material attributes.  
Material attributes and process parameters that can affect quality, but are not described by ranges in 
the DSp would need to be controlled by their specification or target/NOR, respectively. Critical 
processes should always be included as part of the formal DSp, even if they are controlled. Process 
 
 
Questions and answers: Improving the understanding of NORs, PARs, DSp and normal variability of 
process parameters 
EMA/604040/2016EMA/CHMP/CVMP/QWP/354895/2017 
 
 
EMA/CHMP/CVMP/QWP/354895/2017 
Page 3/4 
 
parameters (non-critical process parameters) that have been demonstrated to not be critical within 
their studied range can be defined by target or range outside the formal DSp.  
The justification of a DSp should be presented in the development of the manufacturing process of the 
drug substance and/or drug product (S.2.6 or P.2.3 of Module 3, respectively). The necessary level of 
details will depend on the significance, or the impact, of the DSp. The following should be considered: 
• 
Does the DSp represent parameter ranges that are much wider than what would normally be 
accepted as NORs? 
• 
Does any area of the DSp represent greater risk to quality than the rest of the DSp? 
• 
To what extent do other elements of the control strategy contribute to ensuring output material 
quality? Examples include in-process controls, PAT analytics and downstream processes and 
controls. 
Any multivariate interactions between the DSp parameters need to be studied. In particular, when the 
acceptable range of one parameter within a DSp is dependent on any other parameter, this should be 
thoroughly investigated, including consideration of scale. If it is claimed that no interaction exists 
between parameters, this should be adequately justified. 
Depending on the significance of the DSp, its development should be guided by risk management as 
appropriate (ref. ICH Q8 and Q9).  
4.  How to manage post-approval changes to approved design 
spaces? 
Answer: 
Extension of a design space (DSp) should be submitted as a Type II variation (B.I.e.1 or B.II.g.1). By 
‘extension’, the following is understood: 1) introduction of new material attributes or process 
parameters, 2) extension of the range of existing material attributes or critical process parameters.  
If the change has been foreseen as described in an approved post-approval change management 
protocol (PACMP), depending upon what was agreed, the change can either be submitted as a Type 
IAin or IB notification (B.I.e.5 or B.II.g.5). In accordance with the variation classification guideline, 
changes foreseen in PACMP for a biological/immunological medicinal product are Type IB. 
Restrictions to an approved design space would typically only be necessary if part of the DSp was 
discovered to not produce satisfactory quality material. Such changes to the manufacturing process 
should be submitted as a Type II variation (B.I.a.2.b or B.II.b.3.b): substantial changes to a process 
that may have a significant impact on the quality, safety or efficacy of the product. 
Some changes to input material attributes (specifications) or process parameter settings/ranges can be 
relevant to the DSp, even if the DSp does not specifically cover these parameters. For example, the 
DSp can be established on the condition that other non-critical process parameters, which are required 
in the manufacturing process description, but have been demonstrated not to be critical within the 
range studied,  are kept constant or within their range. Changes to any of these elements should be 
sought in accordance with the variations classification guideline, where, depending upon the nature of 
the changes and type of product some will be possible as Type IA, provided the relevant conditions and 
documentation requirements are fully met, whereas others will be possible as Type IB notifications. In 
all cases the new process must lead to an equivalent product regarding all aspects of quality, safety 
 
 
Questions and answers: Improving the understanding of NORs, PARs, DSp and normal variability of 
process parameters 
EMA/604040/2016EMA/CHMP/CVMP/QWP/354895/2017 
 
 
EMA/CHMP/CVMP/QWP/354895/2017 
Page 4/4 
 
and efficacy and the change should not adversely affect the reproducibility of the process and it should 
be shown that the criticality of the parameter in question is unchanged. 
The variation categories related to changes to manufacturing sites apply regardless of DSp or not. 
However, the continued relevance of any registered DSp should be considered whenever there is a 
manufacturing site change. 
It should be noted that this Q&A has been developed considering the current variation classification; 
Guidelines on the details of the various categories of variations, on the operation of the procedures laid 
down in Chapters II, IIa, III and IV of Commission Regulation (EC) No 1234/2008 of 24 November 
2008 concerning the examination of variations to the terms of marketing authorisations for medicinal 
products for human use and veterinary medicinal products and on the documentation to be submitted 
pursuant to those procedures (2013/C 223/01). 
5.  What type of process flexibility can be acceptable in the 
marketing authorisation dossier, regardless of any 
mentioning of NOR, PAR or DSp? 
Answer: 
The degree of process flexibility is dependent upon how the manufacturing process and its 
development is presented in the marketing authorisation dossier. 
Irrespective of the development approach, the same requirements apply to the level of details in the 
manufacturing process description. 
Steps in the process should have the necessary details in terms of appropriate process parameters, 
along with their target values or ranges.  
The establishment of a DSp is optional. A flexible manufacturing process (ranges) can be registered 
when justified, or alternatively fixed process parameters. However, when a flexible manufacturing 
process is requested (i.e. ranges of process parameters that are wider than what would be accepted as 
a NOR; ranges of input material attributes that can affect the quality of the process output), then the 
process should be established within the framework of a DSp. Reference is made to Q/A # 3, where it 
is  indicated  that the justification for the DSp should be commensurate with the actual degree of 
flexibility represented by that DSp, the impact of the DSp and the risk to quality. 
The process description is considered to be one element of the overall control strategy that is 
presented in an application. Accordingly, the necessary level of details will be considered during 
assessment on a case-by-case basis  for example based on the suitability of any supporting in-process 
controls, PAT analytics or downstream processes and controls. Typically, a one-sided parameter range 
(for example an upper range only) represents great flexibility and will have to be justified by scientific 
rationale. 