30 Churchill Place ● Canary Wharf ● London E14 5EU ● United Kingdom 
An agency of the European Union   
 
 
Telephone +44 (0)20 3660 6000 Facsimile +44 (0)20 3660 5555 
Send a question via our website www.ema.europa.eu/contact 
 
 
© European Medicines Agency, 2017. Reproduction is authorised provided the source is acknowledged. 
 
14 December 2017 
EMA/CHMP/ICH/320985/2016 
Committee for Medicinal Products for Human Use 
ICH Guideline S3A: Note for guidance on toxicokinetics: 
the assessment of systemic exposure in toxicity studies - 
questions and answers 
Step 5 
Adopted by CHMP for release for consultation 
26 May 2016 
Start of public consultation 
26 May 2016 
End of consultation (deadline for comments) 
26 August 2016 
Final adoption by CHMP 
14 December 2017 
Release for information 
14 December 2017 
 
 
 
 
 
 
ICH Guideline S3A: Note for guidance on toxicokinetics: the assessment of systemic exposure in 
toxicity studies - questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 2/11 
 
Document History 
Code 
History 
Date 
S3A Q&As 
Approval by the ICH Assembly under Step 2 and release 
for public consultation. 
May 
2016 
S3A Q&As 
Adoption by the Regulatory Members of the ICH Assembly 
under Step 4. 
November 
2017 
ICH S3A - Note for Guidance on Toxicokinetics: The Assessment of Systemic Exposure in Toxicity 
Studies - October 1994 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 3/11 
 
ICH Guideline S3A- questions and answers 
Table of contents 
Preface ........................................................................................................ 4 
1. Introduction – scope ............................................................................... 5 
2. Basic principal on application of microsampling ...................................... 5 
3. Effect on safety evaluation ...................................................................... 8 
4. Issues regarding the bioanalytical method .............................................. 9 
5. Annex: Q&As linked to the respective sections of ICH S3A guideline ..... 11 
 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 4/11 
 
Preface 
The S3A Guideline was successfully implemented in 1994. However, in recent years, analytical method 
sensitivity has improved, allowing microsampling techniques to be widely used in toxicokinetic (TK) 
assessment. This Q&A document focuses on points to consider before incorporating the microsampling 
method in TK studies, acknowledges its benefits, and some limitations, for assessment of TKs in main 
study animals and its overall important contribution to the 3Rs benefits (Replacement, Reduction and 
Refinement) by reducing or eliminating the need for TK satellite animals. 
 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 5/11 
 
1.  Introduction – scope 
# 
Date of 
Approval 
Questions 
Answers 
1.1 
November 
2017 
What is the definition of microsampling? 
For the purpose of this document, microsampling is a method to collect a very small 
amount of blood (typically ≤50 μL) that is generally used to measure concentrations of a 
drug and/or its metabolites, and subsequently calculate the appropriate TK parameters. 
The appropriate matrices used for microsampling techniques include blood and its 
derived plasma or serum, which can be used in liquid or dried form for transportation, 
storage and subsequent analysis. Microsampling for TKs can be used in rodents and non-
rodents. Microsampling in non-blood derived matrices is outside the scope of this Q&As 
document. 
1.2 
November 
2017 
What are the benefits/advantages of 
microsampling? 
Minimizing the volume of blood collection can reduce pain and distress in animals and 
improve the animal welfare (refinement) of rodents and non-rodents. It can also 
eliminate the TK satellite group in which the TK assessment is conducted in main study 
animals or, reduce the number of required animals in a TK satellite group when used in 
rodent studies (reduction). The benefit is particularly notable for mice, since a significant 
number of these animals are generally used in satellite groups, in TK studies using 
conventional sample volumes. The main scientific advantage of microsampling is that the 
relationship between the safety data and drug exposure can be directly evaluated in the 
same animal. 
2.  Basic principal on application of microsampling 
# 
Date of 
Approval 
Questions 
Answers 
2.1 
November 
2017 
For what types of pharmaceuticals and 
for what types of safety studies can we 
use microsampling? 
Generally, microsampling is applicable to the majority of pharmaceuticals including 
biopharmaceuticals. However, for all types of analytes, consideration should be given on 
a case-bycase basis as to whether the sensitivity of the measurement method is 
appropriate with the small sample volumes available. 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 6/11 
 
# 
Date of 
Approval 
Questions 
Answers 
Microsampling can be used in any type of toxicology study, such as single-dose or 
repeat-dose toxicology studies, and other toxicology studies (e.g. carcinogenicity, 
juvenile and reproductive studies). When microsampling is applied, sampling of a 
representative subgroup is acceptable, as mentioned in the S3A guideline. There are 
published examples demonstrating no impact on key veterinary clinical pathology or 
pathological parameters when small volumes of blood are taken from adult animals. 
However, microsampling is not warranted when the drug concentration is low and the 
majority or all samples are Below the Limit of Quantification (BLQ) (e.g., exposure after 
topical or inhaled administration). However, when the bioanalytical method for 
microsampling has the same Lower Limit Of Quantitation (LLOQ) with that for 
conventional sample volume, microsampling can be used even if majority or all samples 
are BLQ. 
2.2 
November 
2017 
What are the points to consider when 
applying microsampling to TK studies? 
As with other approaches to kinetic sampling, in order to adopt a microsampling 
technique appropriately, a bioanalytical method should be developed and qualified (or 
validated for Good Laboratory Practice studies, in accordance with regulatory 
guideline/guidance in each region) to ensure the reliability of analytical results. Analytical 
characteristics, such as LLOQ, accuracy, precision, influence of matrix using dilution prior 
to storage and the stability of the analyte(s) in the biological matrix for the entire period 
of sampling, storage and processing conditions, should be carefully assessed in order to 
establish the microsampling method. When conventional methods have been already 
used in some studies and microsampling is proposed for others, a comparability of the 
exposure measurement, in the given matrix, between microsampling and conventional 
methods may be necessary. This comparison is particularly important if the conditions 
that the TK samples are presented in are substantially different (e.g. dried sample from 
microsampling vs. liquid sample from conventional sampling). This comparability can be 
done in a separate pharmacokinetic (PK) study to measure area under the matrix level 
concentration-time curve (AUC) and/or Cmax, provided that the appropriate range of 
concentrations is evaluated, and the resulting parameters compared between the 
two methods. This PK study, if needed, should be completed prior to conducting 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 7/11 
 
# 
Date of 
Approval 
Questions 
Answers 
definitive studies that will include the microsampling procedure. A separate PK study for 
comparison may be omitted on a case-by-case basis and with appropriate scientific 
justification, for example, when using similar assay conditions to test blood, plasma or 
serum drawn from the same sampling site. 
During this comparison process, multiple blood collections at a few time points by 
microsampling from a few animals and their subsequent measurement of analyte 
concentrations can be considered in order to check the variability of sampling. Ideally, 
the same matrix should be used throughout the TK studies and also in clinical studies for 
comparison of exposure. When different matrices are used in different studies, the drug 
concentration relationship among matrices should be defined considering appropriate 
factors such as haematological parameters, plasma protein binding ratio and 
blood/plasma (or serum) ratio of the drug, so that systemic exposure can be evaluated 
appropriately from each measurement using different matrices. 
2.3 
November 
2017 
What types of blood collection and what 
types of pretreatment methods are used 
for microsampling? 
Blood can be collected from the tail vein, saphenous vein, etc., using capillary tubes or 
any appropriate miniaturized collection devices. The collected blood, and its derived 
plasma or serum, can be used to measure drug concentrations in either liquid or dried 
form. In some cases, liquid samples can be diluted with the appropriate vehicles or blank 
matrices prior to storage, shipment and subsequent analysis. Dried sample methods are 
also available, wherein the sample is usually applied directly onto cellulose-based or 
other types of materials and then dried. A fixed diameter sub-punch or the whole 
quantity of the sample on the card/device can be extracted and analysed. Recent and 
on-going advancements in microsampling methods have demonstrated the ability to 
collect precise volumes of blood, such that the entire sample can be used for analysis 
without additional volumetric measurements. In addition, newly developed techniques 
could also be considered with adequate validation. 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 8/11 
 
3.  Effect on safety evaluation 
# 
Date of 
Approval 
Questions 
Answers 
3.1 
November 
2017 
How to evaluate the effect of blood 
sampling on the toxicity data and 
wellbeing of the animal in main study 
group? 
When blood sampling is performed on the main study animals, it is important to consider 
the effect of blood collection on the physiological condition of the animals. The main 
factors to consider include; 1) the volume and the number of samples taken in a given 
period; 2) the properties of the test drug (e.g. its effects on red blood cells, 
anticoagulant effect, or haemodynamic properties); 3) the test system (e.g. species, 
age, body weight, total blood volume); and 4) the site of collection. As frequent and 
repeated blood collection may affect physiological data, such as haematological 
parameters, sampling protocols should be appropriately established even with 
microsampling. It is prudent to record the relevant animal data, such as changes in body 
weight, food consumption, haematological parameters (e.g. red blood cell count, 
haemoglobin level, haematocrit value, mean corpuscular volume, electrolytes, total 
proteins), and any effect on the blood collection site (e.g. tissue damage, inflammation). 
Evaluation of these parameters compared to matching control animals, which have had 
the same number and volume of samples drawn as the test drug groups, will be 
important to establish whether any suspected effects are related to test drug or to 
procedures, within the context of the specific study conditions. If previous studies show 
that test drug-related changes to haematological parameters could be exacerbated by 
frequent blood sampling, or it is suspected that the pharmacological action of the test 
drug may induce such effects, the use of satellite groups of animals for TK assessment 
would be warranted, even if microsampling techniques are used. Alternatively, sparse 
sampling* can be used in conjunction with microsampling, if scientifically justified. 
*Sparse sampling in TK studies usually involves the collection of a few blood samples at 
specified timepoints from each animal in a treatment group. The samples are allocated at 
different time points for different animals, often allowing some replicates, and statistical 
inferences are then made about the concentration-time behaviour of the test compound. 
By using proper study designs, investigators can limit the number of samples and the 
amount of blood drawn, so as not to affect the animals' health status, yet still achieve 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 9/11 
 
# 
Date of 
Approval 
Questions 
Answers 
the customary toxicokinetic objectives in a study. 
4.  Issues regarding the bioanalytical method 
# 
Date of 
Approval 
Questions 
Answers 
4.1 
November 
2017 
What are important points to consider in 
bioanalytical method development and 
validation of treatment of liquid or dried 
samples? 
In addition to the analytical method validation stipulated in the bioanalytical 
guideline/guidance in each regulatory region, the following points should be considered 
when analysing samples derived from microsampling: 
For liquid sampling, the following issues should be considered 1) ensuring sample 
homogeneity, for example by pipetting; 2) small volume handling issues (e.g. potential 
freezing/drying effects during the storage and subsequent freeze/thaw process, as 
applicable); 3) potential increase in the LLOQ due to the limited sample volume; 4) 
impact of addition of anticoagulants to small containers/capillaries, resulting in dilution of 
the sample; 5) potential for increased adsorption of the analyte to the collection 
container (i.e. increased surface area to volume ratio); 6) keeping the appropriate 
preservation conditions of the sample; 7) risk of contamination and difficulty of repeated 
sampling using some methods.  
For dried sampling techniques (e.g. spotting onto cellulosic or non-cellulosic card, 
polymer matrix, etc.), it is important to select the method with adequate and 
reproducible recovery and minimal matrix interference with detection of the drugs. If the 
sub-punch of the dried spot approach is used, it is important to ensure that detection of 
the analyte is not affected by different haematocrit values, especially for small molecule 
drugs. The effect of haematocrit on analyte detection can be measured by using blood 
with different haematocrit values and spiking with test drugs of known concentrations. It 
is also important to confirm the uniformity of the spots by evaluating analyte levels from 
multiple samples punched out from one spot or, by evaluation, for example, using 
radiolabels. Both of these issues can be minimized if an accurate volume of blood is 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 10/11 
 
# 
Date of 
Approval 
Questions 
Answers 
collected on the device and the entire sample is subsequently analysed. 
Incurred sample reanalysis (ISR) should be conducted according to each regional 
guidance/guideline, if described. When doing ISR, care should be taken to ensure 
sufficient sample volumes or numbers of replicates (e.g. spots, containers, or tips) are 
retained for ISR. 
 
 
 
ICH Guideline S3A- questions and answers 
 
EMA/CHMP/ICH/320985/2016 
Page 11/11 
 
5.  Annex: Q&As linked to the respective sections of ICH S3A 
guideline 
Sections of ICH S3A 
Guideline 
1: Introduction 
2: The objective of toxicokinetics and 
the parameters which may determined 
3: General principles to be considered 
4: Toxicokinetics in the various areas of 
toxicity testing – 
specific aspects 
5: Supplementary Notes 
6: References (other ICH Guidance) 
Other ICH Guidelines 
1. Introduction – Scope 
1 
1 
 
3.10 
 
Note 1 
 
 
2 
1 
 
3.5 
 
Note 1 
 
 
2. Basic principal on application of microsampling 
1 
 
2 
 
4 
 
 
 
2 
 
 
3.1 
3.10 
 
 
 
 
3 
 
 
3.10 
 
 
 
 
3. Effect on safety evaluation 
1 
 
 
3.3 
3.5 
 
 
 
 
4. Issues regarding the bioanalytical method 
1 
 
 
3.10 
 
Note 1 
 
 
 