30 Churchill Place ● Canary Wharf ● London E14 5EU ● United Kingdom 
An agency of the European Union  
Telephone +44 (0)20 3660 6000 Facsimile +44 (0)20 3660 5555 
Send a question via our website www.ema.europa.eu/contact 
 
© European Medicines Agency, 2016. Reproduction is authorised provided the source is acknowledged. 
25 February 2016 
EMA/CHMP/BWP/548524/2008 rev 1 
Committee for Medicinal Products for Human Use (CHMP) 
Guideline on epidemiological data on blood transmissible 
infections 
Draft agreed by Biologics Working Party 
14 May 2015 
Adoption by CHMP for release for consultation 
21 May 2015 
Start of public consultation 
1 June 2015 
End of consultation (deadline for comments) 
31 August 2015 
Agreed by Biologics Working Party 
17 February 2016 
Adoption by CHMP 
25 February 2016 
Date for coming into effect 
30 August 2016 
Note: 
1. This Guideline should be read together with the appendices published in this link: EMA/735037/2015 Rev.1
2. This revised guideline uses the terms Blood establishment and centres, i.e. the term “organisation” has been
replaced with “blood establishments” to be consistent with the “Guideline on the scientific data requirements for a 
Plasma master File (PMF) Revision 1 EMEA/CHMP/BWP/3794/03”.   
Keywords 
PMF, epidemiology, first time tested donors, repeat tested donors, 
prevalence, incidence, residual risk, risk estimate, control charts, 
trends. 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 2/18 
 
Guideline on epidemiological data on blood transmissible 
infections 
Table of contents  
Table of contents ......................................................................................... 2 
Executive summary ..................................................................................... 3 
1. Introduction (background) ...................................................................... 3 
2. Scope....................................................................................................... 3 
3. Legal basis .............................................................................................. 4 
4. Purpose ................................................................................................... 4 
5. Infectious disease markers ..................................................................... 4 
6. Donor classifications ............................................................................... 5 
7. Prevalence and incidence ........................................................................ 6 
8. Reporting of epidemiology data on viral markers in donor population..... 8 
9. PMF Holder`s assessment of  donor population epidemiological data: 
monitoring change over time and alert limits ............................................ 10 
10. Residual risk: Risk estimation of undetected viraemic donations in 
routine testing ........................................................................................... 11 
11. Reporting and interpretation of “worst case” estimates of the “window 
period risk” ............................................................................................... 14 
12. Epidemiological data requirement for approval of blood/plasma 
collection centres and blood establishments for inclusion in the PMF ....... 15 
 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 3/18 
 
Executive summary 
This guideline (EMA/CHMP/BWP/548524/2008) outlines the scientific data requirements for 
epidemiological data on blood transmissible infections to be included in applications for Plasma Master 
File certification submitted to the EMA. The revision of this guideline follows an earlier revision of this 
guideline (EMA/CHMP/BWP/548524/2008) which came into effect in 2011 and superseded the 
guideline, which came into operation in July 2005 (Ref. EMEA/CPMP/BWP/125/04). 
1.  Introduction (background) 
Applicants for Plasma Master File (PMF) certification are required to include the donor population 
epidemiological data on blood transmissible infections for each individual blood/plasma collection 
centrea and blood establishmentb listed in the PMF application. 
The present document represents a revision of the “Guideline on epidemiological data on blood 
transmissible infections” which was undertaken by experts appointed by the CHMP/BWP who took into 
account both the results of a public consultation and additional experience acquired from the 
evaluations of the epidemiological data submitted by applicants for EMA PMF certification. 
2.  Scope 
The guideline outlines the scientific data requirements for epidemiological data (including collection, 
collation, use of data for the calculation of epidemiological parameters such as incidence and 
prevalence rates, and interpretation) for applications to the EMA for PMF certification, re-certification 
and variation, as appropriate.  
The objective of the revision is to provide additional guidance to PMF holders on: 
- Residual risk calculation - HBV incidence adjustment factor, “first time tested donor adjustment 
factor”, and viraemic window periods used in calculations. 
- Extension of the  monitoring period to more than 3 years now that data is available over longer 
periods in the format required by the guideline. 
- The usefulness of control charts (or other graphical tools) to identify the presence of trends in viral 
marker rates for blood establishmentsb/countries. 
- Approaches to identify trends in viral marker rates on an individual collection centre basis.  
- Epidemiological data requirements for approval of blood/plasma collection centres and blood 
establishments, which will facilitate the evaluation of epidemiological data of new PMF Blood 
establishments and adequate selection of the appropriate donor population.  
                                                
a Centre is defined as “collection site or premise where blood or plasma is collected (and may also be processed and 
stored)” in the Guideline on the scientific data requirements for a plasma master file (Doc. Ref. 
EMEA/CHMP/BWP/3794/03 Rev.1).  The use of the term “collection centre” in this guideline means a specific site 
where blood/plasma is collected, including any associated mobile sites. 
 
b “Organisations” replaced with the term “blood establishments” as defined in Directive 2002/98/EC “any structure 
or body that is responsible for any aspect of the collection and / or testing of human blood or blood components, 
whatever their intended purpose, and their processing, storage, and distribution when intended for transfusion. This 
does not include hospital blood banks.”  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 4/18 
 
3.  Legal basis 
Commission Directive 2003/63/EC of 25 June 2003, amending Directive 2001/83/EC of the European 
Parliament and of the Council on the Community code relating to medicinal products for human use 
introduces the concept of the PMF. Part III, section 1.1 of Annex I lays down specific requirements 
related to the PMF and states that “For medicinal products derived from human blood or plasma and by 
derogation from the provisions of Module 3, the dossier requirements mentioned in "Information 
related to the starting and raw materials", for starting materials made of human blood/plasma may be 
replaced by a PMF certified in accordance with this Part”. It also states that “In accordance with the 
provisions of Article 109, as amended by Directive 2002/98/EC, which refers to the requirements for 
donors and the testing of donations, the Plasma Master File shall include information on the plasma 
used as starting/raw material”. Epidemiological data on blood transmissible infections are part of the 
information required. 
Data on incidence and prevalence of transfusion transmissible infectious markers in donors of blood 
and blood components are also required as part of the annual reports of blood establishments (Annex 
II of Directive 2002/98/EC1). 
4.  Purpose 
The requirement to collect epidemiological data on blood transmissible infections is intended to obtain 
information on the infection risk in a specific donor population and is thus an essential part of the 
measures taken to ensure an adequate selection of blood and plasma donors. Adequate selection of 
donors is one of the important measures for the safety of plasma derivatives together with the virus 
testing of donations and pools, and the virus reduction capacities of manufacturing steps. The purpose 
of collecting epidemiological data is to characterise the donor population with respect to infection risk, 
to allow detecting epidemiological changes over time, and to allow comparison of risks between donor 
populations.  
This is one of the measures to ensure that donations do not come from donors with a high probability 
of being infected with blood transmissible agents. Continuous epidemiological evaluation at individual 
blood/plasma collection centres together with an annual update of the PMF documentation is therefore 
required. Data on prevalence and incidence of blood transmissible infectious agents in donors and the 
estimated risk of infectious donations entering the plasma supply should be presented and discussed 
according to the present guidance.  
The PMF is also subject to variations e.g. concerning the approval of new blood/plasma centres and 
blood establishments for inclusion into the PMF and epidemiology information in that specific donor 
population should be submitted (see section 12). 
5.  Infectious disease markers 
Epidemiological data should be collected on those blood-borne infectious agents for which a potential 
transmission by blood products is well recognised and routine testing of blood and plasma donations is 
mandatory. These infectious agents currently include human immunodeficiency virus (HIV), hepatitis B 
virus (HBV) and hepatitis C virus (HCV).  
The principles which underlie the testing for the markers for these viruses also apply to the collection 
of epidemiological data.  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 5/18 
 
While currently, the minimum data collected cover anti-HIV 1+2, anti-HCV and hepatitis B surface 
antigen (HBsAg) test results, the PMF holder should also report separately the results of additional 
screening testsc (e.g. NAT assays).  
Clearly, a donor tested positive for a specific virus, by both serological and NAT tests, should be 
reported as a single case according to the relevant definition below.  
Only confirmed infections should be reported using the following definition2: 
Confirmed seropositive 
Repeatedly reactive (= 2 times reactive) in a screening test and 
positive in at least one supplementary test based on a different 
principle. 
NAT only positive 
Positive in a NAT assay for a specific virus (HIV, HCV or HBV), not 
found seropositive for that virus in serological screening, and shown 
to be true positive by second NAT test or later serology. 
 
“NAT only positives” are in most cases indicative of recent infection and should, therefore, be reported 
separately from “Confirmed seropositives”. Donations that are reactive in the initial screening tests but 
negative or indeterminate in confirmatory tests should not be included as positives. 
Reporting of confirmed cases will reflect truly positive donors/donations rather than limitations in the 
specificity of the testing system. If donors are excluded from the donor population on the basis of a 
positive NAT test without a confirmatory test being performed, or on the basis of non-confirmed 
reactive serological test results, these data should also be reported, but separately from the data on 
confirmed positives. In all cases the PMF holders should clearly explain their approach and criteria for 
excluding donors. 
Further practical details for reporting data are set out in Section 8. 
6.  Donor classifications 
The Council Recommendation on the suitability of blood and plasma donors and the screening of 
donated blood in the European Community (98/463/EC)3 provides the following definitions of types of 
donors: 
Prospective donor 
Someone who presents himself/herself at a blood or plasma collection 
establishment and states his/her wish to give blood or plasma. 
First time donor 
Someone who has never donated either blood or plasma. 
Repeat donor 
Someone who has donated before but not within the last two years in 
the same donation centre. 
Regular donor 
Someone who routinely donates blood or plasma (i.e. within the last 
two years), in accordance with minimum time intervals, in the same 
donation centre. 
 
It is not the aim of the exercise to acquire information on individuals who express an intention to 
donate, or individuals present in a collection centre without being tested. In order to get information 
on the prevalence and incidence of viral infections in the donor populations of individual collection 
centres, a test result for the viruses of interest needs to be available. Therefore, for the purpose of the 
                                                
c Data on anti-HBc are not specifically required. 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 6/18 
 
assessment of epidemiological data of donor populations, the following definitions are used in this 
documentd: 
First time tested donor 
Person whose blood/plasma is tested for the first time for infectious 
disease markers (with or without donation) without evidence of prior 
testing in a given blood system. 
Repeat tested donor 
Person whose blood/plasma has been tested previously for infectious 
disease markers in a given blood system. 
 
A given blood system means a system that has records of whether a donor has donated before and the 
results of previous testing. 
7.  Prevalence and incidence 
This section first describes the general concepts of incidence and prevalence for infectious diseases and 
then the application of these concepts in the study of blood/plasma donor population. 
Prevalence and incidence can be defined as follows: 
Prevalence 
Frequency of infection identified (including both past and recent 
infections) at a specified point in time or over a specified time period 
in a defined population. 
Incidence 
Rate of newly acquired infection identified over a specified time period 
in a defined population. 
 
Incidence is the measure of new infections and prevalence is a measure of the extent of infection in a 
population. 
Prevalence and incidence are complementary in that they provide information on past and current risk 
of infection in the population.  
1. High prevalence and high incidence is indicative of established infection with continuing 
transmission.  
2. High prevalence and low incidence is indicative of established infection but with intervention 
measures (e.g. education on risk of infection, effective therapy) having been introduced.  
3. Low prevalence and high incidence indicates infection which is probably recently introduced into 
the population.  
4. Low prevalence and low incidence would indicate that there is little or no evidence of past or 
current infection.  
Clearly while the 1st and 3rd scenarios could be considered to be indicative of a high risk population, the 
2nd scenario may imply medium risk since established infections may create a reservoir from which 
future new infections may arise, and the 4th scenario would indicate a low risk population. 
There are certain characteristics of the blood/plasma collection system that need to be taken into 
account when parameters are defined for the collection of epidemiological data4, 5, 6, 7, 8, 9: 
                                                
d Similar definitions are used in the Council of Europe Annual Survey Questionnaire on the collection, 
testing and use of blood and blood products in Europe. 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 7/18 
 
-Prevalence data in donors tested for the first time provide information on the population presenting to 
become blood/plasma donors and, who have not deferred themselves through the donor questionnaire. 
-Determination of incidence is important because newly infected donors who are in the “window 
period” (i.e. donors whose recent infection is not recognised by the applied tests) may donate 
infectious blood or plasma. 
In the context of the study of a donor population;  
1. Prevalence can be defined as: 
(formula 1): 
No. of positive donors in a specified period 
x 100,000e 
Total No. donors in the same specified period 
 
2. Incidence in “repeat tested donors” can be measured as: 
 
 (formula 2): 
 
 
No. of positive “repeat tested donors” with a previous negative 
donation in the study period 
x 100,000f   
 
The sum of the time between the first and the last test result of 
every donor during the study periodg (= person-years at risk) 
 
If HBsAg and/or HBV DNA are used as marker(s) for HBV infections, an adjustment factor may be 
needed to obtain an estimation of true incidence, as the presence of detectable amounts of these 
markers in donations of HBV infected donors can be transient  (see also Section 10). 
In practice, the data required to determine incidence according to the above definition are difficult to 
obtain because the intervals between the first and last donation/test sample of every individual donor 
during the study period have to be known for a large number of donors. 
According to published literature10, an alternative approach to estimate incidence “in repeat tested 
donors” is as: 
 
(formula 3): 
No. of positive “repeat tested donors” in the study period with a 
previous negative donation 
x 100,000  
Total No. of donations from “repeat tested donors” in the study 
period x mean interdonation interval (IDI) (expressed in years)               
(= person-years at risk) (*) 
 
(*) The number of person-years at risk can be estimated by dividing the total number of donations from “repeat tested 
donors” by the average annual number of donations per repeat donor, i.e. the denominator can be expressed as:  
 
Total No. of donations from “repeat tested donors” in the study period 
No. of donations /No. of “repeat tested donors” x time period (years) 
 
If the calculation was to be made over one calendar year, the denominator of formula 3 would then 
equal the number of repeat tested donors in a calendar year (expressed as person-years). In practice, 
                                                
e This is often expressed per 100,000 donors.  
f This is often expressed per 100,000 person-years at risk.  
g Expressed in years (or fraction of a year). 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 8/18 
 
the “incidence” calculation would equal the rate of positive “repeat tested donors” in a calendar year 
(see formula 5 Section 8.2).  
Important note: In the calculation of No. positive “repeat tested donors” in the study period with a 
previous negative donation”, the previous negative test result does not have to be in the same study 
period (e.g. a donor that only donates once during the study period would be included, provided that 
the donor’s blood/plasma has been tested at some point in the past in the given blood system). 
  
If formula 2 or 3 are not used, the alternative algorithm should be clearly defined and justified and a 
literature reference should be given by the PMF Holder. 
3. Incidence in “first time tested donors” 
In “first time tested donors” incidence may be estimated by differential serological testing, e.g. using a 
combination of sensitive and less-sensitive antibody tests for HIV6. Newly acquired (incident) infections 
are identified on the basis of a positive result with a more sensitive test combined with a negative 
result with a less sensitive serological test. Another approach uses NAT positive test results combined 
with a negative result in a serological screening test9. This approach is straightforward for HIV and 
HCV, while for HBV further differentiation between an incident and a so-called occult infection course is 
needed. Different investigations of blood donor populations suggest for worst case estimation of “first 
time tested donors” incidence the respective “repeat tested donors” incidence multiplied with an 
adjustment factor. (See also section 10.)  
8.  Reporting of epidemiology data on viral markers in donor 
population  
In reporting epidemiological data, it is important to clearly describe the testing result definitions (see 
Section 5) and the donor classifications (see Section 6) as this will affect the results obtained and the 
comparability of data. 
For each blood establishment, the donor population which actually donates into the plasma pool should 
be described. This should include information on how many donations are collected on average from 
one donor per year (frequency of donations), and information on whether donations from “first time 
tested donors” are used in plasma pools. 
As a result of the screening programme, a donor might be defined as “positive” for a certain virus 
based on different approaches. The PMF Holder should provide a statement on the confirmation 
strategy for reactive test results (See also Section 5 of this guideline). If confirmatory testing has not 
been done these data should be reported separately. Only “confirmed seropositives” and “NAT only 
positives” should be reported. “NAT only positives” should be reported separately from serological 
testing results, as outlined in Tables 1 and 2 in the Appendix.  
The potential risk for plasma-derived products arises from undetected viraemic donations entering the 
plasma pool. A viraemic donor may donate once or several times during the period of infection when 
the donor is tested negative by screening tests i.e. during the “window period”. Therefore, for the risk 
assessment the total number of donations collected should also be reported (see Section 10). 
Data should be reported per country, per blood establishment and per individual collection centre, and 
per calendar year (January-December) using the tabular formats given in Tables 1 and 2 in the 
Appendix of this guideline (Ref. EMA/651459/2015). The data should be reported for the referenced 
year under reporting and the four previous years. In order to facilitate a relative assessment of these 
data, the data should be presented in absolute numbers and calculated per 100,000 donors. If both 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 9/18 
 
whole blood recovered plasma and plasmapheresis plasma are collected, data should also be 
summarised separately for each of these two categories.  
8.1.  “First time tested donor” population  
According to the definition in Section 6, “first time tested donors” are persons who are “tested for the 
first time for infectious disease markers (with or without donation) and without evidence of prior 
testing in a given blood system”.  
For PMF holders using the applicant/qualified donor systemh, the “first time tested donor population” 
represents a sub-set of “applicant donors” (i.e. “applicant donors” that are tested for the first time in a 
given system). 
Prevalence in “first time tested donors” in a specified period: 
 
   (formula 4): 
 
No. of positive “first time tested” donors” in a calendar year 
   
x100,000i 
 
Total No. of “first time tested donors” in the same calendar year 
For the purpose of the PMF data submission, the calculation is presented over 1 calendar year (see 
Table 1, in appendix). 
8.2.   “Repeat tested donor” population  
As described in Section 6, a “repeat tested donor” is a “person whose blood/plasma has been tested 
previously for infectious disease markers in a given blood system”, (this includes “regular donors” and 
“repeat donors”). For PMF holders using the applicant/qualified donor system, “repeat tested donors” 
includes “applicant donors” tested for a second time, “applicant donors” requalifying after an interval of 
6 months or more, and “qualified donors”. 
As explained in section 5, if the calculation of “incidence” in “repeat tested donors” is made over 1 
calendar year, the calculation would equal the rate of positive “repeat tested donors” in a calendar 
year: 
Rate of positive “repeat tested donors” in a given period   
  (formula 5): 
No. of positive “repeat tested donors” in a calendar year 
   
X 100,000i 
Total No. of “repeat tested donors” in the same calendar year 
For the purpose of the PMF data submission, the calculation is presented over 1 calendar year (see 
Table 2 in appendix). 
 
Important note: the previous negative test result does not have to be in the same calendar year 
(e.g. a donor that only donates once during the calendar year would be included provided that the 
donor’s blood/plasma has been tested at some point in the past in the given blood system). 
                                                
h Qualified donor: Individuals who have been qualified for continued donations by passing two donor screenings 
and two sets of serological viral testing for HIV, HBV and HCV within six months, with a minimum interval between 
the screenings according to national recommendations or requirements.  
   Applicant donor: A donor going through the testing to become a qualified donor. Donations from an applicant 
donor are held in quarantine until cleared by an acceptable qualifying donation. 
i This is often expressed per 100,000 donors.  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 10/18 
 
9.  PMF Holder`s assessment of  donor population 
epidemiological data: monitoring change over time and alert 
limits 
The PMF Holder should assess the epidemiological data and the changes over time. The purpose is to 
identify collection centres with rates of viral markers outside the normal range for the given donor 
population in the PMF and to discuss any overall changes in the rates in (parts of) the donor 
population. The PMF Holder may assess changes over time and compare viral marker rates in the 
donor population with the use of control charts. 
Any trend observed in the results, introduced by new or additional screening tests (e.g. NAT assays), 
should also be included in the assessment and discussed.  
Furthermore, alert limits should be defined with the purpose to allow identification of outlier of 
individual collection centres characterised by rates of viral markers outside the normal range of the 
given donor population(s) in the PMF. 
In addition, for individual collection centres, which have been identified above the alert limits, the 
remedial corrective actions taken should be described, and their effectiveness, discussed and assessed. 
For a particular blood establishment/country demonstrating a significant higher prevalence/incidence 
than other blood establishments/countries in the PMF, a comparison with the general population might 
be valuable for the evaluation of the data. 
Monitoring change  
A comparison of the epidemiological data for the referenced year under reporting, with data from all 
previous years as far as data are available, should be submitted for the individual collection centres, 
blood establishments and countries. Control charts (or other graphical tools) may be used to monitor 
changes overtime.  
- Blood establishments and countries 
Control charts (or other graphical tools) should be submitted for each country and blood establishment 
included in the PMF, to facilitate the assessment and comparison of the changes over time of viral 
markers rates in the donor population. Data should be included for the referenced year under reporting 
and all previous years, as far as these data are available.  
Control charts (or other graphical tools) should be provided for “repeat tested donors” and “first time 
tested donors” separately.  If in a blood establishment and/or country both whole blood recovered 
plasma and plasmapheresis plasma is collected, it is strongly recommended to monitor changes 
separately, unless otherwise justified. 
In case obvious upward trends are observed over time for a country or blood establishment, an 
analysis of the potential reasons and respective interpretation of the data should be provided.  
-Individual collection centres 
Any obvious upward changes shown over time, for one or more viral markers’ rates in individual 
collection centres, should be discussed. 
Control charts (or other graphical tools) to represent the annual viral markers’ rates of individual 
collection centres can be useful tools as part of the quality management system. They may also be 
used to identify those centres that show obvious changes over time for one or more viral markers’ 
rates.  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 11/18 
 
Alert limits  
The criteria in place used by the PMF Holder to establish alert limits for epidemiological data, and the 
system to identify individual blood/plasma collection centres reporting data above the alert limits, 
should be described. The exceeding of alert limits should trigger corrective actions. The alert limits 
should be set to allow identification of outliers, i.e. centres with rates of viral markers outside the 
normal range for the respective donor population in the PMF. Separate alert limits should be set for 
“first time tested donors” and “repeat tested donors”. Whereas alert limits for “first time tested donors” 
have a function of setting criteria for anomalies with regards to prevalence (potentially associated with 
incidence), alert limits for “repeat tested donors” serve the primary purpose of identifying outliers of 
incidence. In order to establish limits that are sufficiently discriminating for incidence, the basis for 
calculation alert limits for “repeat tested donors” should be kept separate from “first time tested 
donors” data. 
All centres exceeding the alert limit for one or more viral markers’ rates should be discussed in an 
overview of the respective centres. In addition, the potential reasons for the epidemiological situation 
in these centres should be discussed, taking also into account all available data from previous reporting 
years. Corrective actions and their effectiveness should be described and discussed. This may also 
include more recent follow-up data during the procedure under assessment.  
In the case that an individual collection centre has exceeded the established alert limits for the donor 
population in the PMF, it would be useful to include the individual centre control chart as part of the 
discussion.  
10.  Residual risk: Risk estimation of undetected viraemic 
donations in routine testing   
Introduction 
PMF holders are requested to provide estimates of the risk of  viraemic donations passing undetected 
in routine testing, due to collection of donations with testing results that are truly negative to the tests 
in use (i.e. during the “window period” for the test in use, as further described below). 
This section provides a generic approach to present and perform the necessary calculations to estimate 
the risk of undetected viraemic donations. The proposed calculation is a simplified worst-case approach 
and PMF holders should use the method described to facilitate assessment of the results. Any other 
approach needs to be fully described and appropriately justified and sufficient detail should be provided 
to enable the assessment of the calculations. Guidance on reporting the results of the risk estimate is 
provided in section 11. 
10.1.  Method to calculate “Window period risk“  
As a standard approach, PMF holders are advised to use the basic “incidence” method 4, 10 to estimate 
the risk that an infected (potentially viraemic) donor would give a blood/plasma donation with a 
negative test result because of the recency of infection.  This risk is referred to throughout this 
document as the “window period risk”, and can be calculated according to: 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 12/18 
 
 
formula 6: 
“Window period risk” 
for infection Yj 
= 
Incidencek in “repeat 
tested donors” of 
infection Y 
x 
viraemic window period 
of routine tests for 
infection Y (expressed 
in years) 
 
The risk is estimated as the product of the incidence and the time interval in which a new infection 
would pass undetected (expressed in years). The result should be multiplied by 10, as it is common 
and advisable to report the risk per million donations, as specified in Table 4. 
-Incidence  
Incidence in “repeat tested donors” in the year under reporting is estimated using formula 5. In case 
no infections in “repeat tested donors” were detected in this year, the time period should be extended 
to previous years up to and including the last year in which an infection was reported.  
For HBV, the use of the “HBV incidence adjustment factor” is recommended (see section 10.3.) 
The estimation of the “window period risk” in “first time tested donors” can be deduced from the 
incidence in “repeat tested donors” with a “first time tested donor adjustment factor” as recommended 
in section 10.2. 
- Window period 
The window period is a justified estimate of the time period (length) in which a test method is unable 
to detect 1) a recent infection because there is not yet virus in blood (non-viraemic phase), or 2) the 
virus load is below the methods’ limit of detection of NAT or antigen testing (viraemic phase), or, 
where 3) NAT or antigen testing is not performed, the antibodies are not yet detectable in the testing 
method applied. Typically, the length of the window period for NAT is shorter than for serological 
testing: hence a larger reduction in risk is generally expected and achieved by NAT. As a worst case 
scenario, the viraemic phase of the window period, with virus concentration below the sensitivity level 
of screening assays, can be estimated by using viral replication kinetics and less sensitive testing 
scenarios. This scenario implies that for HIV and HBV less sensitive NATs (e.g. testing of larger 
minipools as practised by some blood establishments), has only marginal additional benefit when 
compared to CE-marked antibody (HIV) or HBsAg (HBV) tests. For HCV, the minipool NAT has more 
benefit with high HCV concentration during early infection phase compared to the anti-HCV non-
reactive plateau phase.  
For the purpose of this guideline, for the worst case residual risk calculations, the following estimates 
of viraemic window periods are recommended to be used: 
HCV: 8 days  
HIV: 15 days 
HBV: 35 days 
According to formula 6 the value should be expressed in years. 
For reasons outlined above, these worst case viraemic window periods are considered appropriate in 
case of both serology and NAT testing.  
The “basic incidence” method recommended in this section can misestimate (overestimate or 
underestimate) the “window period risk” if the IDI of donors who acquire new infections is significantly 
different (longer or shorter) to the IDI for all other donors. More specifically, the risk may be 
overestimated when the IDI of donors who acquire new infections is significantly longer than the IDI of 
                                                
j Risk estimates should be reported separately for HBV, HCV, and HIV.  
k  This is expressed per 100,000 donors.  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 13/18 
 
donors who did not acquire infections. In this case, it is desirable that PMF holders report a) the 
median IDIs for their “repeat tested donors” who acquired a new infection, and b) the mean IDIs for all 
“repeat tested donors”, and comment on the likely overestimation of risk if these intervals differ 
markedly (i.e. by ~20% or more). Otherwise, the overestimate may be considered as a worst-case. 
10.2.  “First time tested donor” incidence adjustment factor  
To estimate the residual risk of undetected infectious donations in “first time tested donors” in the 
window period, according to the formula 6 in section 10.1, an estimate of the incidence in “first time 
tested donors” is required. This estimate can be obtained from the incidence in “repeat tested donors” 
of the same donor population multiplied by a factor (i.e. “first time tested donor incidence adjustment 
factor”) that represents the relative risk of new infections amongst “first time tested donors” compared 
to “repeat tested donors”.  
Based on scientific publications on incidence in donor populations, PMF holders may use, for the “first 
time tested donors” residual risk calculations, an assumed threefold higher incidence, for each of the 
virus infections, in “first time tested donors” compared to “repeat tested donors”.  
“First time tested donor incidence adjustment factor”: 3 
Any alternative “First time tested donor incidence adjustment factor” chosen by a PMF holder should be 
based on a justified local measure of the risk of new infection in “first time tested donors” 
9, 11, 12, 13, 14, 15, 16, 17. 
10.3.  HBV incidence adjustment factor  
The HBV incidence calculations should be adjusted for the transient nature of markers for HBV 
infection, i.e. for the probability that a new HBV infection in a “repeat tested donor” has become 
undetectable by the time of his or hers first donation after acquiring HBV infection. As the presence of 
detectable amounts of HBsAg and HBV DNA in donations of HBV infected donors can both be transient, 
PMF holders are expected to use an HBV incidence adjustment factor for incidence estimates based on 
serology or NAT testing. 
The value of the HBV incidence adjustment factor depends on:  
a) the time period during which markers for HBV infection can be detected in plasma from HBV 
infected adults and  
b) the IDI 18, 19, 20, 21, 22  
As information on the presence of detectable amounts of HBV DNA in HBV infected persons is limited, 
for the calculation of the “window period risk”, it is advised to use a worst-case estimate of the HBV 
incidence adjustment factor based on the assumptions used by Korelitz et al.18. 
Korelitz et al. assumed that: 
- 5% would have persistent antigenaemia,  
- 70% of infected donors would have transient antigenaemia (lasting an average of 77 days - Seed et 
al22), and 
- 25% of infected donors would have no antigenaemia  
The probability of detection of HBV infection by HBsAg testing in these different groups is 1 (persistent 
antigenaemia), 77/IDI (transient antigenaemia), and 0 (no antigenaemia). The overall probability of 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 14/18 
 
detection can be calculated using formula 7, which takes into account the probability of detection and 
the relative contribution for the different antigenaemia groups.  
formula 7: Probability of detection by HBsAg testing = (5%x1) + (70%x (77/IDI)) + (25%x0) 
The HBV incidence adjustment factor can be calculated as: [1/ Probability of detection by HBsAg 
testing] x100. 
As a worst case estimate, it is assumed that a donor donates once every six months (i.e. IDI 180 
days), resulting in an HBV incidence adjustment factor of 2.9 to be used in the calculation of the risk 
estimate(s).  
HBV incidence adjustment factor (IDI 180 days) = [1/ (5%x1) + (70%x (77/180)) + (25%x0)] x 100]=2.9 
For donor populations with an IDI ≤ 77 days, the probability of detection of transient antigenaemia is 
1. In this case, an HBV incidence adjustment factor of 1.3 can be used, only taking into account the 
absence of antigenaemia in 25% of the population.  
HBV incidence adjustment factor (IDI ≤ 77 days) = [1/ (5%x1) + (70%x1) + (25%x0)] x 100]= 1.3 
10.4.  Method to calculate the risk due to inabilities or failures of testing 
systems to detect established infections 
There is a risk of infectious donations passing undetected through routine testing due to inabilities or 
failures of the testing systems to detect established (prevalent) infections. For each individual virus 
and test system reported the risk of releasing a truly positive donation is a function of the sensitivity of 
the tests, the risk of errors in the testing system, and the prevalence of the infection amongst donors.  
The risk of releasing a truly positive donation can be estimated for any given test system as (formula 
8)23: 
Risk = [ 
1-sensitivity 
+(1 – 
1-sensitivity 
) x error rate 
] x  Prevalence 
sensitivity 
sensitivity 
 
Generally with state of the art methods, this risk is a direct function of the prevalence of infections 
amongst tested donors and is small compared to the risk of passing of ‘window period’ donations. 
Therefore, PMF holders are not required to provide quantitative estimates of the risk due to prevalent 
infections. However, if PMF holders are using donations with a relatively high prevalence (e.g. for new 
donors, tabulated in Tables 1 and 2 of the Appendix) this risk should not be neglected and should be 
addressed in the Overall Safety Strategy.  
11.  Reporting and interpretation of “worst case” estimates 
of the “window period risk” 
The details in Table 3 in the Appendix should suffice to describe the PMF holder’s calculations 
performed to estimate the risk of undetected infectious donations as per the method recommended in 
section 10.  
The calculation performed for the residual risk estimate should represent a reasonable “worst case” 
situation. In applications covering very diverging plasma sources and/or testing strategies, it might be 
appropriate to perform and present different potential “worst case” calculations, for example:  
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 15/18 
 
-a “worst case” risk estimate for plasmapheresis donors from one blood establishment selected on the 
basis of relatively high viral markers’ rates in “repeat tested donors”,  
-a “worst case” risk estimate for whole blood donors from one blood establishment selected on the 
basis of relatively high viral markers’ rates in “repeat tested donors” and/or the use of “first time 
tested donors” with relatively high viral markers’ rates in “first time tested donors”.   
The criteria used for the definition of the “worst case(s)” should be described and justified by the 
applicant. Criteria to be taken into account when performing this exercise include for example the 
epidemiological situation (viral markers’ rates), the use of plasma from “first time tested donors”, the 
presence/absence of additional voluntary tests, and significant differences in test sensitivities or pool 
sizes (number of donations pooled for testing). If deemed necessary additional scenarios and their 
respective estimates will be requested from the applicants during the evaluation period. 
The results of the calculations should be reported using the tabular format in Table 4 in the Appendix. 
The risk estimates should be reported separately for HBV, HCV, and HIV by calendar year, per million 
donations. If plasma from donations from “first time tested donors” is used, the residual risk in “first 
time tested donors” should be presented separately as well as included in the overall estimation of the 
risk. 
Interpretation of the risk estimates requires understanding of the range of uncertainty around the 
point estimate and this should be discussed in the dossier. 
The additional application of risk-reduction measures to the plasma supply post donation screening 
(e.g. inventory hold, look-backs, or further NAT testing of manufacturing plasma pools) is not to be 
included in the risk estimate. These additional measures and their impact on the reduction of risk of 
plasma supply should be presented in the overall safety strategy described in section 1.2 of the 
Guideline on the scientific data requirements for a Plasma master File (PMF) Revision 1 
EMEA/CHMP/BWP/3794/03.  
The potential worst-case virus load in representative manufacturing pool(s) should be calculated and 
discussed based on the results of the risk estimate(s). 
12.  Epidemiological data requirement for approval of 
blood/plasma collection centres and blood establishments for 
inclusion in the PMF   
At the time of filing for approval of new blood/plasma collection centres and blood establishments the 
following epidemiological data is considered as minimum:  
For a new blood/plasma collection centre and/or blood establishments at least 6 months 
epidemiological data from a significant number of donors should be submitted. The epidemiological 
data should be compared to the rates of viral markers in the other collection centres already approved 
in the concerned PMF.  
For a new blood/plasma collection centre and blood establishments in a country which is new for a 
particular PMF, the epidemiological data obtained should also be compared to the viral rates in the 
general population of the new country.  
A new blood/plasma collection centre, within a blood establishments already included in the concerned 
PMF, could be accepted with less than 6 months submission of epidemiological data, provided 
satisfactory justification of the PMF holder is submitted. However, depending on the geographical 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 16/18 
 
and/or the epidemiological situation of the area where the new blood/plasma collection centre is 
located, 6 months epidemiological data may still be required. This may be relevant for large countries. 
If the blood/plasma collection centres and blood establishments applied for have already operated for 
some time, all available epidemiological data, including a trend analysis, should be submitted in 
accordance with the requirements of this guideline. 
If the infection rates for the blood/plasma collection centres and blood establishments applied for are 
out of the range compared to the other collection centres and blood establishments already approved 
in the concerned PMF (e.g. higher rates “first time tested donors”, higher rate NAT only positives), a 
risk assessment together with a justification for acceptance of the new blood/plasma collection 
centres/ blood establishments s should be provided. 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 17/18 
 
References 
                                                
1 Directive 2002/98/EC of the European Parliament and of the Council of 27 January 2003 setting 
standards of quality and safety for the collection, testing, processing, storage and distribution of 
human blood and blood components and amending Directive 2001/83/EC. Official Journal 2003; L33: 
30-40. 
 
2 Questionnaire on the collection, testing and use of blood and blood products in Europe, Council of 
Europe, Strasbourg, 7 June 2003, SP-HM (2003). 
 
3 Council Recommendation of 29 June 1998 on the suitability of blood and plasma donors and the 
screening of donated blood in the European Community (98/463/EC). Official Journal 1998; L203: 14-
26. 
 
4 Schreiber GB, Busch MP, Kleinman SH, Korelitz JJ. The risk of transfusion transmitted viral infections. 
The Retrovirus Epidemiology Study. N Engl J Med 1996; 334:1685–1690. 
 
5 Pillonel J, Saura C, Couroucé AM. Screening of viral markers for HIV, HBV and HCV infections in blood 
donors in France and residual risk of viral transmission by blood transfusion. Eurosurveillance 1998; 3: 
76-79. 
 
6 Janssen RS, Satten GA, Stramer SL, et al. New testing strategy to detect early HIV-1 infection for use 
in incidence estimates and for clinical and prevention purposes. JAMA 1998, 280:42-8; erratum in 
JAMA 1999; 281: 1893. 
 
7 Schreiber GB, Glynn SA, Busch MP, Sharma UK, Wright DJ, Kleinman SH. Incidence rates of viral 
infections among repeat donors: are frequent donors safer? Retrovirus Epidemiology Donor Study. 
Transfusion 2001; 41(6): 730-735. 
 
8 Janssen MP, Cator EA, van der Poel CL, Schaasberg WP, Bonsel GJ, van Hout BA. Monitoring viral 
incidence rates: tools for the implementation of European Union regulations. Vox Sang 2009; 96(4): 
298-308.  
 
9 Dodd RY, Notari EP 4th, Stramer SL. Current prevalence and incidence of infectious disease markers 
and estimated window-period risk in the American Red Cross blood donor population. Transfusion 
2002; 42(8): 975-979. 
 
10 Glynn SA, Kleinman SH, Wright DJ, Busch MP. International application of the incidence rate/window 
period model.Transfusion 2002; 42: 966-972. 
 
11 Bush MP, Glynn SA, Stramer SL, Strong DM, Caglioti S, Wright DJ, Pappalardo B, Kleinman SH. A 
new strategy for estimating risks of transfusion–transmitted viral infections based on rates of detection 
of recently infected donors. Transfusion 2005; 45:254-264. 
 
12 Lackritz EM, Satten GA, Aberle-Grasse J, et al. Estimated risk of transmission of the human 
immunodeficiency virus by screened blood in the United States. New England Journal Medicine 
1995;333:1721-5. 
 
13 Cumming PD, Wallace EL, Schorr JB, Dodd RY. Exposure of patients to HIV through the transfusion 
of blood components that test antibody negative. N Eng J Med 1989;321:941-6. 
 
14 Zou S, Stramer SL, Dodd RY. Donor Testing and Risk: Current Prevalence, Incidence, and Residual 
Risk of Transfusion-Transmissible Agents in US Allogeneic Donations. 2012. Transfusion Medicine 
Reviews 26: 119-128 
 
15 O’Brien SF, Yi QL, Fan W, Scalia V, Fearon MA, Allain JP. Current incidence and residual risk of HIV, 
HBV and HCV at Canadian Blood Services. Vox Sanguinis 2012. 103:83–86. 
 
16 Reduction of the risk of transfusion-transmitted viral infection by nucleic acid amplification testing in 
the Western Cape of South Africa: a 5-year review. Vox Sanguinis 2013. 104:93–99. 
 
 
Guideline on epidemiological data on blood transmissible infections 
(EMA/CHMP/BWP/548524/2008) 
 
 
Page 18/18 
 
                                                                                                                                                        
17 Zou S, Fang CT, Dodd RY for the ARCNET Research Group and Jerome H. Holland Laboratory for 
Biomedical Sciences. A method for estimating incidence rate of infectious diseases among first-time 
blood donors. Transfusion 2008. 48:1827-1832. 
 
18 Korelitz JJ, Busch MP, Kleinman SH, Williams AE, Gilcher RO, Ownby HE, Schreiber GB. A method for 
estimating hepatitis B virus incidence rates in volunteer blood donors. Transfusion 1997:37;634-640. 
 
19 Hoofnagle JH, Seeff LB, Buskell-Bales Z et al. Serological responses in HB. In: Vyas GN, Cohen SN, 
Schmid R eds. Viral hepatitis: a contemporary assessment of aetiology, epidemiology, pathogenesis 
and prevention. Philadelphia: Franklin Institute Press, 1978:219-42. 
 
20 Hoofnagle JH, Schaffer DF. Serological Markers of Hepatitis B virus Infection (review). Seminars in 
Liver Disease 1986; 6: 1-10. 
 
21 Mimms LT, Mosley JW, Hollinger FB, Aach RD, Stevens CE, Cunningham M, Vallari DV, Barbosa LH, 
Nemo GJ. Effect of concurrent acute infection with hepatitis C on acute hepatitis B virus infection. BMJ 
1993:307;1095-97. 
 
22 Seed CR, Cheng A, Ismay SL, Bolton WV, Kiely P, Cobain TJ, Keller AJ, Virology Subcommittee of the 
National Donor and Product Safety Committee, Australian Red Cross Blood Service. Assessing the 
accuracy of three viral risk models in predicting the outcome of implementing HIV and HCV NAT donor 
screening in Australia and the implications for future HBV NAT. Transfusion 2002; 42 1365-72. 
 
23 Soldan K, Davison K, Dow B. Estimates of the frequency of HBV, HCV and HIV infectious donations 
entering the blood supply in the United Kingdom, 1996 to 2003. Viral safety of blood. Eurosurveillance 
10; Issues 1-3 Jan-Mar 2005; 17-19 