ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval 
Prolongation and Proarrhythmic Potential - questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 1/37 
 
 
24 March 2022 
EMA/CHMP/ICH/415588/2020 
Committee for Human Medicinal Products 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation 
of QT/QTc Interval Prolongation and Proarrhythmic 
Potential - questions and answers 
Step 5 
 
Transmission to CHMP 
23 July 2020 
Adoption by CHMP 
23 July 2020 
Release for public consultation 
28 August 2020 
Deadline for comments  
28 November 2020 
Final adoption by CHMP 
27 January 2022 
Date for coming into effect 
27 August 2022 
 
 
 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval 
Prolongation and Proarrhythmic Potential - questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 2/37 
 
E14/S7B Q&As 
Code 
History 
Date 
E14 Q&As 
Approval by the ICH Steering Committee under Step 4 
4 June 2008 
E14 
Q&As (R1) 
Approval by the ICH Steering Committee under Step 4 
of four newly added Questions on: Sex Differences; 
Incorporating New Technologies; Late Stage 
Monitoring; and Heart Rate Correction. 
5 April 2012 
E14 
Q&As (R2) 
Approval by the ICH Steering Committee under Step 4 
of four newly added Questions on: Concentration-
Response Relationships; Combination Products; Large 
Targeted Proteins and Monoclonal Antibodies; and 
Special Cases. 
21 March 
2014 
E14 
Q&As (R3) 
Approval by the ICH Assembly under Step 4 of the 
revision of the Question #5.1 on: Use of Concentration 
Response Modeling of QTc Data 
10 December 
2015 
E14/S7B 
Q&As 
Approval by the ICH Assembly under Step 4 
21 February 
2022 
 
 
 
 
 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval 
Prolongation and Proarrhythmic Potential - questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 3/37 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation 
of QT/QTc Interval Prolongation and Proarrhythmic 
Potential - questions and answers 
Table of contents 
E14 Q&As .................................................................................................... 4 
1. Electrocardiograms methodology............................................................................... 4 
2. Gender .................................................................................................................. 9 
3. Positive control ..................................................................................................... 10 
4. Study design ........................................................................................................ 11 
5. Use of concentration response modeling of QTc data ................................................. 12 
6. Special cases ........................................................................................................ 16 
7. Electrocardiograms monitoring in late stage clinical trials ........................................... 18 
S7B Q&As .................................................................................................. 22 
1. Integrated risk assessment .................................................................................... 22 
2. Best practice considerations for in vitro studies ......................................................... 25 
3. Best practice considerations for the in vivo QT studies ............................................... 31 
4. Principles for proarrhythmia models ........................................................................ 35 
 
 
 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 4/37 
 
 
E14 Q&As 
1.  Electrocardiograms methodology 
# 
Date of 
Approval 
Questions 
Answers 
1.1 
June 
2008 
Please discuss who should read 
electrocardiograms (ECGs), including the 
number and training of readers and the 
need for readers to be blinded. 
 
The document recommends that the reader should be skilled but does not identify 
specific training that is needed. A technician reading with cardiologist over-read would 
certainly be consistent with the guidance. The attempt of the guidance to limit the 
number of readers represented an attempt to increase consistency. The guidance asks 
for assessment of intra- and inter-reader variability and suggests "a few skilled readers" 
(not necessarily a single reader) to analyse a whole thorough QT study, since many 
readers may increase variability. Training would be another way to improve consistency. 
It is recommended for the thorough QT Study that core ECG laboratories blind subject, 
time and treatment in order to reduce potential bias. The T wave analysis, which calls for 
all 12 leads, can be performed after the QT analyses, and requires comparison to the 
baseline ECG; it can, however, be blinded as to treatment. 
1.2 
June 
2008 
What is the position of ICH regarding the 
role of the following reading methods in 
the thorough QT/QTc study and other 
clinical trials? 
• 
fully manual 
• 
fully automated 
• 
manual adjudication (manual over-
read, computer-assisted, semi-
automated) 
The techniques currently in use for the measurement of ECG intervals can be classified 
into three broad categories: fully manual, fully automated, and manual adjudication. 
Within each of these general categories, many different methodologies are subsumed 
that differ in terms of lead selection, the conventions used for defining T wave offset, and 
the criteria for the inclusion and exclusion of U waves. 
ECG readings can be performed on the following waveform presentations: 
• 
Raw waveforms: ECG waveforms recorded from a single lead; 
• 
Representative waveforms (median beats, reference cycles): Compositional 
waveforms constructed by a computer-based averaging process that involves 
aligning and combining data from all dominant, normally conducted raw ECG 
waveforms from a single lead; 
• 
Global Waveforms: Composite representation of cardiac electrical activity constructed 
by superimposing representative waveforms from all or several simultaneously 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 5/37 
 
# 
Date of 
Approval 
Questions 
Answers 
recorded leads to form a spatial-vector complex, by weighted averaging of individual 
representative complexes with low noise and long duration, or by other methods. 
Fully Manual 
When using a fully manual reading technique, a human reader is responsible for 
examining the ECG waveform and placing the fiducial points to mark the beginning and 
the end of the intervals, without the assistance of a computer algorithm. Fully manual 
methods of fiducial point placement can be applied to raw, representative, and global 
waveforms. When fully manual measurements are made from the raw ECG waveforms in 
a single lead, three or more cycles should be averaged where available to produce the 
final determination of interval duration. An advantage of this approach is that the reader 
will not be influenced by prior computer placement of the fiducial points, but a weakness 
can be inter- and intra-reader variability, especially when measurements are performed 
over an extended time period (e.g., several months). Laboratories using manual reading 
techniques should observe standard operating procedures based on prospectively defined 
criteria for determining where the fiducial points should be placed. All readers in the 
laboratory should be trained in the consistent application of these criteria. 
Fully Automated 
Fully automated reading methods rely entirely upon a computer algorithm for the 
placement of the fiducial points and the measurement of the ECG intervals. Automated 
ECG interval measurements can be performed on raw, representative, or global ECG 
waveforms. Most digital electrocardiographs are equipped with algorithms that perform 
measurements on global waveforms. Although automated methods have the advantage 
of being consistent and reproducible, they can yield misleading results in the presence of 
noise or when dealing with abnormal ECG rhythms, low amplitude P or T waves, or 
overlapping U waves. The techniques used for construction and measurement of 
representative waveforms and global waveforms vary between different computerized 
algorithms and between different software versions within individual equipment 
manufacturers. As a result, between-algorithm and within-manufacturer variability of 
fully automated measurements can confound serial comparisons when the equipment or 
algorithm is not constant. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 6/37 
 
# 
Date of 
Approval 
Questions 
Answers 
Manual Adjudication (Manual Over-Read/Computer-Assisted/Semi-Automated) 
The manual adjudication approach refers to reading methods in which a computer 
algorithm is responsible for the initial placement of the fiducial points on the ECG 
waveform. A human reader subsequently reviews the algorithmic placement of the 
fiducial points, performing adjustments wherever the computerized measurements are 
considered to be inaccurate. This approach can have the advantage of greater 
consistency and reproducibility than fully manual readings, while providing an 
opportunity to correct any mistakes made by the algorithmic readings. Laboratories 
using manual adjudication techniques should observe standard operating procedures 
based on prospectively defined criteria for determining when fiducial points should be 
corrected. All readers in the laboratory should be trained in the consistent application of 
these criteria. The adjudication procedure should normally be performed on all 
waveforms being used for interval determination. If an alternative approach is used, such 
as adjudication limited to outlier intervals above and below a reference range, this 
methodology should be validated as described in Question 1.3. 
The ICH E14 Guideline currently recommends either fully manual or manual adjudication 
approaches for clinical trials in which the assessment of ECG safety is an important 
objective, such as the thorough QT/QTc study. When the thorough QT study is positive, 
fully manual or manual adjudication methods are currently recommended for an 
adequate sample of patients in late phase studies (see Section 2.3 in E14 document). 
When the thorough QT/QTc study is negative, routine ECG safety assessments in late 
phase clinical trials using fully automated reading methods would be adequate. 
1.3 
June 
2008 
The ICH E14 Guideline contains the 
following statement: “If 
wellcharacterized data validating the use 
of fully automated technologies become 
available, the recommendations in the 
guidance for the measurement of ECG 
intervals could be modified.” What would 
Efforts to develop more sophisticated and reliable methods for automated ECG readings 
for both QT interval and T wave morphology assessment are encouraged. There are at 
present no large scale studies to validate the use of fully automated reading methods in 
patients; however, there are examples of thorough QT/QTc studies in healthy volunteers 
in which automated methods have been used and validated for QT interval 
measurements against manual methods. 
QT Interval measurement 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 7/37 
 
# 
Date of 
Approval 
Questions 
Answers 
be expected of a sponsor that wished to 
validate and apply an automated reading 
method for regulatory submissions? 
There are at present no clear and widely accepted criteria for validation of new semi-
automated or automated methods, but it is expected that each would be validated 
independently for its ability to detect the QT/QTc prolongation effects of drugs that are 
near the threshold of regulatory concern. Data supporting the validation of a new method 
should be submitted and could include descriptive statistics, BlandAltman plots of 
agreement, superimposed plots of the baseline- and placebo- adjusted QTc and the RR 
as a function of time, together with data from any trials that have employed the method. 
T wave morphology assessment 
The suitability of automated ECG reading techniques for the assessment of morphological 
abnormalities has not yet been demonstrated. If a sponsor intends to develop a fully 
automated approach, without visual assessment for morphological changes, validation 
studies should include a demonstration that the automated method is capable of reading 
and interpreting a test set of abnormal ECGs correctly (e.g., abnormalities of T wave 
morphology, overlapping U waves). As with methods for QT interval determination, there 
are at present no clear and widely accepted criteria for validation of novel methods. 
Because changes in morphology can affect interval measurement, fully manual or 
manual adjudication (as defined in Question 1.2) techniques should be performed if 
treatment-emergent changes in morphology are observed. If, on the other hand, no 
morphology changes are observed, this would support the use of automated 
methodologies, provided they have been validated. 
1.4 
April 
2012 
How does a sponsor incorporate new 
technology or validate new methodology 
into the measurement and/or analysis of 
the QT interval? 
The ICH process is better suited to the determination of regulatory policy once the 
science in a particular area has become more or less clear. In general, it is not well-
suited to the qualification or validation of new technology. Sections 2.5.1 and 2.5.2 of 
the ICH E14 Guideline are rather discouraging about methodology outside conventional 
carts and humandetermined measurements. Since ICH E14 was issued, 12-lead 
continuous recording devices have largely supplanted cart recorders in thorough QT 
studies without a formal validation process because of their performance in the context 
of a positive control. The impact of other innovative technologies can be assessed in 
studies incorporating a positive control. While some technologies could be assessed using 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 8/37 
 
# 
Date of 
Approval 
Questions 
Answers 
other techniques in the absence of a positive control, this is more complex and beyond 
the scope of this Q&A. 12-lead continuous recording devices and other new technologies 
can be used in late phase clinical trials. Even though a positive control is not used in late 
stage studies, the new technology could be validated in other studies (such as the 
thorough QT study). In cases where a thorough QT study is not done, a sponsor can 
provide alternative methods for validating the technology. 
1.5 
April 
2012 
The ICH E14 Guideline states that QT 
interval corrected by Fridericia’s and 
Bazett’s correction should be submitted 
in all applications; is this still necessary? 
Is there a recommended approach to QT 
correction that is different than that 
specified in ICH E14? 
Changes in heart rate could variably influence a drug’s effect on repolarisation (i.e., QT 
interval) and correction methods with different characteristics are often applied. The 
principles set below would be applicable in all clinical studies (thorough QT or other 
studies). In adults, Bazett’s correction has been clearly shown to be an inferior method 
of correcting for differences in heart rate among and within subjects. Therefore, QT 
interval data corrected using Bazett’s corrections is no longer warranted in all 
applications unless there is a compelling reason for a comparison to historical Bazett’s 
corrected QT data. Presentation of data with a Fridericia’s correction is likely to be 
appropriate in most situations but other methods could be more appropriate. There is no 
single recommended alternative (see Q&A 1.4 on Incorporating New Technologies), but 
the following are some considerations. 
1. Analyses of the same data using different models for correcting QT can generate 
discordant results. Therefore, it is important that the method(s) of correction, criteria 
for the selection of the method of correction, and rationale for the components of the 
method of correction be specified prior to analysis to limit bias. Model selection ought 
to be based on objective criteria and consider the uncertainty in parameter 
estimates. Alternative methods of correction should be used only if the primary 
method fails the pre-specified criteria for selection of the method of correction. 
2.  Corrections that are individualized to a subject’s unique heart rate QT dynamic are 
not likely to work well when the data are sparse or when the baseline data upon 
which the correction is based do not cover at least the heart rate range observed on 
study drug. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 9/37 
 
2.  Gender 
#
 
 
Date of 
Approval 
Questions 
Answers 
2.1 
June 
2008 
There are recognized differences in the 
baseline QTc between men and women. 
These were noted in early versions of 
the guidance. In E14, however, it is 
recommended that outliers be 
categorized as >450, >480 and >500 
ms, regardless of gender. Can you say 
why there is no gender difference in the 
recommendation? 
The 450, 480, and 500 ms categories refer to the values the E14 document suggests 
sponsors might use in characterizing outliers. The numbers previously specified for males 
and females referred to “normal” QTc values, which may differ for men and women. This 
section was not included in the final document, however, and such considerations would 
be largely irrelevant to larger durations (e.g., 480, 500 ms). As the thorough QT/QTc 
study is designed to examine the propensity of a drug to prolong the QTc ierval, it is 
appropriate to perform the study in male or female healthy volunteers. 
2.2 
April 
2012 
Should we enroll both sexes in a 
thorough QT study, and does the study 
need to be powered for independent 
conclusions about each sex? 
Post-pubertal males have lower heart-rate corrected QT intervals than do pre-pubertal 
males or females generally. Women are generally smaller than men, so their exposure to 
a given fixed dose of a drug will generally be higher, and, if a drug prolongs QT, it can be 
expected to prolong it more in women because of the higher exposure. It is not settled 
whether and how often there are sex differences in response to QT-prolonging drugs not 
explained by exposure alone.  
The thorough QT study is primarily intended to act as a clinical pharmacology study in a 
healthy population using a conservative primary objective defining the drug’s effect on 
QT. It is unlikely that any of a variety of baseline demographic parameters would 
introduce a large difference in QT response to a drug in subpopulations defined by factors 
such as age, co-morbidity, and gender that is not explained by exposure.  
It is encouraged, but not mandatory, to include both men and women in the thorough QT 
study. Analyses of Concentration-Response Relationship (CRR) by sex can be helpful for 
studying the effect of the drug on QT/QTc interval in cases where there is evidence or 
mechanistic theory for a gender difference. However, the primary analysis of a thorough 
QT study should be powered and conducted on the pooled population. If the primary 
analysis is negative and if there is no other evidence suggesting gender differences, 
subgroup analysis by sex is not expected. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 10/37 
 
3.  Positive control 
#
 
 
Date of 
Approval 
Questions 
Answers 
3.1 
June 
2008 
The ICH E14 Guideline emphasizes the 
importance of assay sensitivity and 
recommends the use of a positive 
control. In order to accept a negative 
thorough QT/QTc study, assay sensitivity 
should be established in the study by 
use of a positive control with a known 
QT-prolonging effect. Please clarify how 
to assess the adequacy of the positive 
control in the thorough QT study. 
The positive control in a study is used to test the study’s ability (its “assay sensitivity”) 
to detect the study endpoint of interest, in this case QT prolongation by about 5 ms. If 
the study is able to detect such QT prolongation by the control, then a finding of no QT 
effect of that size for the test drug will constitute evidence that the test drug does not in 
fact prolong the QT interval by the amount of regulatory concern. There are two 
conditions required for ensuring such assay sensitivity: 
1. The positive control should show a significant increase in QTc; i.e., the lower bound 
of the one-sided 95% Confidence Interval (CI) must be above 0 ms. This shows that 
the trial is capable of detecting an increase in QTc, a conclusion that is essential to 
concluding that a negative finding for the test drug is meaningful;  
2. The study should be able to detect an effect of about 5 ms (the QTc threshold of 
regulatory concern) if it is present. Therefore, the size of the effect of the positive 
control is of particular relevance. With this aim, there are at least two approaches:  
a) To use a positive control showing an effect of greater than 5 ms (i.e., lower 
bound of a one-sided 95% CI >5 ms). This approach has been proven to be 
useful in many regulatory cases. However, if the positive control has too large an 
effect, the study’s ability to detect a 5 ms QTc prolongation might be questioned. 
In this situation, the effect of the positive control could be examined at times 
other than the peak effect to determine whether an effect close to the threshold 
of regulatory concern can be detected;  
b) To use a positive control with an effect close to 5 ms (point estimate of the 
maximum mean difference with placebo close to 5 ms, with a one-sided 95% CI 
lower bound >0). In using positive controls with smaller effects it would be very 
important to have a reasonably precise estimate of the drug’s usual effect.  
Importantly, whatever approach is used, the effect of the positive control (magnitude of 
peak and time course) should be reasonably similar to its usual effect. Data suggesting 
an underestimation of QTc might question the assay sensitivity, thus jeopardizing the 
interpretability of the thorough QT study results. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 11/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
3.2 
June 
2008 
Please clarify the need for blinding the 
positive control in the thorough QT 
study. 
The use of a double-blinded positive control does not appear to be essential, provided 
that the reading of ECGs is performed in a blinded manner as described in Question 1.2 
and the study is carefully designed to ensure that specified study procedures are 
followed uniformly. This means that the same protocol for administering the test drug 
and placebo, taking blood samples and collecting the ECG data should also be used when 
giving the positive control. This does not mean that other aspects of the study, such as 
the duration of treatment with the positive control and the other treatment groups, 
would be identical. If blinding of the positive control is performed, common methods 
include the use of double-dummy techniques and over-encapsulation. 
4.  Study design 
#
 
 
Date of 
Approval 
Questions 
Answers 
4.1 
June 
2008 
In ICH E14, the recommended metric to 
analyse for a cross-over study is the 
largest time-matched mean difference 
between the drug and placebo (baseline-
adjusted) over the collection period. 
Please discuss the most appropriate 
metric to assess a drug’s effect on 
QT/QTc interval when the data are 
collected in a placebo-controlled parallel 
design study (i.e., when there is no 
corresponding placebo value for each 
patient). 
Regardless of the study design, “the largest time-matched mean difference between drug 
and placebo (baseline-adjusted)” is determined as follows: The mean QTc for the drug 
(i.e., averaged across the study population) is compared to the mean QTc for placebo 
(averaged across the study population) at each time point.  
The “largest time-matched mean difference between drug and placebo” is the largest of 
these differences at any time point. The term “baseline-adjusted” in ICH E14 implies that 
the baseline data are taken into account in the statistical analysis.  
Differences in baseline assessment between cross-over and parallel design studies are 
discussed in Question 4.2. 
4.2 
June 
2008 
Please discuss the need for baseline 
measurements, and when needed, how 
Adjustment for baseline measurements is potentially useful for several purposes, 
including detection of carry-over effects, reducing the influence of inter-subject 
differences and accounting for diurnal effects such as those due to food. There is no 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 12/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
they should be collected, for cross-over 
and parallel design thorough QT studies. 
single best approach for baseline adjustment, but all planned baseline computations 
should be prospectively defined in the clinical trial protocol. Two kinds of baseline are 
commonly used: “time-matched” baseline (taken at exactly the same time-points on the 
day prior to the beginning of treatment as on the treatment day) and "pre-dose" baseline 
(taken shortly prior to dosing). The “pre-dose” baseline is used for adjustment for inter-
subject differences but not for diurnal effects. The choice of baseline is influenced by 
whether the study is parallel or cross-over. 
For a parallel-group study a time-matched baseline allows the detection of differences in 
diurnal patterns between subjects that would not be detected by a predose baseline. In a 
parallel study a “time-matched” baseline day, if performed, would ideally occur on the 
day before the start of the study.  
In contrast, in a cross-over study a time-matched baseline is usually not necessary 
because adjustments for subject- and study-specific diurnal variation are implicit by 
design in the assessment of time-matched drug/placebo differences in QT/QTc effect. 
The “pre-dose” baseline is therefore usually adequate for cross-over studies.  
Obtaining replicate ECG measurements (for example, the average of the parameters 
from about 3 ECGs) within several minutes of each nominal time point at baseline and at 
subsequent times will increase the precision of the estimated changes in QT/QTc effect. 
5.  Use of concentration response modeling of QTc data 
#
 
 
Date of 
Approval 
Questions 
Answers 
5.1 
December 
2015 
The ICH E14 Guideline states (in Section 
3.2.3, page 10) that analysis of the 
relationship between drug concentration 
and QT/QTc interval changes is under 
active investigation. Has this 
investigation yielded a reasonable 
Concentration-response analysis, in which all relevant data across all doses are used to 
characterize the potential for a drug to influence QTc, can serve as an alternative to the 
by-time-point analysis or intersection-union test as the primary basis for decisions to 
classify the risk of a drug. In either case this result is an important component of the 
totality of evidence assessment of the risk of QT prolongation. The overall assessment of 
risk of QT prolongation includes nonclinical data, the time course of QT prolongation, the 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 13/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
approach to concentration-response 
modeling during drug development? How 
can assessment of the concentration-
response relationship guide the 
interpretation of QTc data? 
magnitude of QT prolongation, categorical analyses of outliers, and certain adverse 
events in patients that can signal potential proarrhythmic effects. There are many 
different types of models for the analysis of concentration-response data, including 
descriptive pharmacodynamic (PD) models (e.g., linear or Emax models), or empirical 
models that link pharmacokinetic (PK) models (dose-concentration-response) with PD 
models. It is recognized that concentration-response analyses of the same data using 
models with different underlying assumptions can generate discordant results. Therefore, 
it is important that the modeling methods and assumptions, criteria for model selection, 
rationale for model components, and potential for pooling of data across studies be 
specified prior to analysis to limit bias. Prospective specification of model characteristics 
(e.g., structural model, objective criteria, goodness of fit) based on knowledge of the 
pharmacology is recommended whenever possible. On occasion, the QT effect is not a 
direct function of plasma concentration. For example, drugs that cause QT prolongation 
as a result of changes in protein synthesis or trafficking or drugs with accumulation into 
myocardial tissues might demonstrate hysteresis. Testing for model assumptions, 
hysteresis (a plot of data by-time point and a hysteresis loop plot), and goodness of fit 
should be documented. Concentration-response analysis can be challenging when more 
than one molecular entity-multiple drugs or parent plus metabolites-contributes to the 
QTc effect. 
Dose and exposure definitions  
• 
Therapeutic dose: dose evaluated in Phase 3 trial or recommended in product 
labeling  
• 
Clinical exposure: mean steady state maximum concentration (Cmax,ss) associated 
with the maximum therapeutic dose  
• 
High clinical exposure: exposure (Cmax,ss) achieved when the maximum therapeutic 
dose is administered in the presence of the intrinsic or extrinsic factor (e.g. organ 
impairment, drug-drug interaction, food effect, etc.) that has the largest effect on 
increasing Cmax,ss 
• 
Supratherapeutic dose: dose that provides exposures (mean Cmax) exceeding the 
high clinical scenario 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 14/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
Important considerations 
Concentration-response data need not come from a dedicated QT study, nor even a 
single study, but there are several new and important considerations.  
1) Data can be acquired from first-in-human (FIH) studies, multipleascending dose 
(MAD) studies, or other studies provided that the concentrations that can be safely 
achieved are well above the exposure at the maximum therapeutic dose at steady-
state, and reflect high clinical exposure scenario situations such as drug-drug and 
drug-food interactions, organ dysfunction, and/or genetically impaired metabolism. 
Whenever possible, sponsors are encouraged to explore a wide dose range in early 
phase studies to enable characterization of effects at high concentrations.  
2) Efficient concentration-response analysis using data acquired in studies with other 
purposes requires as much quality control as is needed for a dedicated study. This 
includes robust, high-quality electrocardiogram (ECG) recording and analysis 
sufficient to support a valid assay for ECG intervals (see ICH E14 and Q&A #1).  
3) If there is an intention to pool ECG interval data from multiple studies, it is important 
to test for heterogeneity. Pooling of studies that were not planned for this purpose 
can produce bias. This potential should be critically discussed in the analysis plan.  
4) A separate positive control would not be necessary if either of the following 
conditions is met:  
a) There are data characterizing the response at a sufficient multiple (commonly 
2x) of the high clinical exposure (see ICH E14 Section 2.2.2); 
or  
b) If the high clinical exposure has been achieved in the clinical ECG assessment, 
but a sufficient multiple has not been obtained (e.g., for reasons of safety or 
tolerability, saturating absorption, etc.), then a nonclinical integrated risk 
assessment can be used as supplementary evidence. The reason higher doses 
were not tested should be adequately justified. See ICH S7B Q&A 1.1 for details; 
in summary, the nonclinical studies should include (1) a hERG assay, following 
best practice considerations (see ICH S7B Q&A 2), that shows low risk as defined 
in ICH S7B Q&As 1.1-1.2 and (2) no evidence of QTc prolongation in an in vivo 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 15/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
assay conducted according to ICH S7B at exposures that cover high clinical 
exposures (see ICH S7B Q&As 1.1 and 3; note that some recommendations only 
apply to decision making under ICH Q&A 6.1). 
Decision-making 
Both the intersection-union test and the concentration-response analysis can estimate 
the maximum effect of a drug treatment on the QTc interval, but they are not used to 
test the same hypothesis. As mentioned above, inspection of the time course of QT 
prolongation is important. However, hypothesis testing based on a by-time point analysis 
(intersection-union test or point estimate and confidence intervals) is inappropriate in 
studies designed for a concentration-response analysis, if not powered to assess the 
magnitude of QT prolongation for each time point. When using a concentration-response 
analysis as the primary basis for decisions to classify the risk of a drug, the upper bound 
of the two-sided 90% confidence interval for the QTc effect of a drug treatment as 
estimated by exposure-response analysis should be during later stages of drug 
development is not needed. (See ICH E14, Section 2.2.4 and Q&A #7). 
Other uses 
In addition to serving as the basis for regulatory decision-making, concentration-
response analysis has established its utility in several settings enumerated below. 
Providing insight into regimens not studied directly  
An understanding of the concentration-response relationship can help predict the QT 
effects of doses, dosing regimens, routes of administration, or formulations that were not 
studied directly. Interpolation within the range of concentrations studied is more reliable 
than extrapolation above the range.  
Predicting QTc effects of intrinsic and extrinsic factors that affect PK  
Understanding the concentration-response relationship can help predict the effects of 
intrinsic (e.g., cytochrome P450 isoenzyme status) or extrinsic (e.g., drug-drug PK 
interactions) factors, possibly affecting inclusion criteria or dosing adjustments in later 
phase studies.  
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 16/37 
 
6.  Special cases 
#
 
 
Date of 
Approval 
Questions 
Answers 
6.1 
March 
2014 
The ICH E14 Guideline states that in 
certain cases a conventional thorough 
QT study might not be feasible. In such 
cases what other methods should be 
used for evaluation of QT/QTc and 
proarrhythmic potential? 
An integrated nonclinical and clinical QT/QTc risk assessment can be particularly valuable 
when a thorough QT study or concentration-QTc analysis meeting similar quality control 
as needed for a dedicated study as described in 5.1 is not feasible. This situation can 
arise under scenarios where a placebo-controlled comparison is not possible; safety 
considerations preclude administering supratherapeutic doses to obtain high clinical 
exposures and/or safety or tolerability prohibit the use of the product in healthy 
participants. The design elements that include placebo and healthy participant dosing 
assist in decreasing variability, but their absence does not preclude interpretation.  
The integrated nonclinical and clinical QT/QTc risk assessment should include:  
1. The hERG assay, an in vivo QT assay, and any follow-up nonclinical studies, 
especially those selected to overcome the challenges encountered in the clinical 
studies (see ICH S7B Q&As 1.1 and 1.2); and  
2. Alternative QT clinical study designs incorporating ECG assessments with as many of 
the usual “thorough QT/QTc” design features as possible (see ICH E14 Section 2.2 
and Q&A 5.1).  
In situations where it is not possible to evaluate the QT/QTc effects at high clinical 
exposure, it is particularly important that the nonclinical in vivo studies are conducted at 
exposures covering the high clinical exposure (see ICH E14 Q&A 5.1 for definition of high 
clinical exposure).  
An integrated QT/QTc risk assessment can also be particularly valuable for drugs with 
confounding heart rate effects that could impact accurate determination of the QTc. 
Advanced methodologies for controlling (e.g., pacing) or correcting for heart rate 
changes in the nonclinical in vivo studies and/or conducting QTc assessments in the 
intended patient population might be informative in this situation. If tolerance to the 
chronotropic effect develops with repeat dosing, upward titration regimens can 
sometimes be employed to avoid or minimize the confounding effects of drug-induced 
heart rate changes on the QTc assessment. 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 17/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
Decision-Making  
A totality of evidence argument based on the results of an integrated nonclinical and 
clinical QT/QTc assessment could be made at the time of marketing application.  
A drug that meets the following criteria would be considered to have a low likelihood of 
proarrhythmic effects due to delayed repolarization:  
1. The nonclinical studies, following best practice considerations for in vitro studies (see 
ICH S7B Q&A 2) and in vivo studies (see ICH S7B Q&A 3), show low risk as defined 
in ICH S7B Q&A 1.1.  
2. The high-quality ECG data (see ICH E14 and E14 Q&A #1) collected in the alternative 
QT clinical assessment do not suggest QT prolongation, generally defined under this 
Q&A as an upper bound of the two-sided 90% confidence interval around the 
estimated maximal effect on ΔQTc less than 10 ms, as computed by the 
concentration-response analysis or the intersection-union test. If applicable, there 
should be no notable imbalances between treatment/dose arms in the proportion of 
subjects exceeding outlier thresholds.  
3. A cardiovascular safety database that does not suggest increased rate of adverse 
events that signal potential for proarrhythmic effects (ICH E14 Section 4).  
When justified, a totality of evidence argument for a drug to have a low likelihood of 
proarrhythmic effects due to delayed repolarization could still be made for a drug that 
has an upper bound of the two-sided 90% confidence interval around the estimated 
maximal effect on ΔQTc of 10 ms or more. The determination will depend on the quality 
and details of the clinical data (e.g., estimated ΔQTc mean and upper bound values, 
slope of any concentration-ΔQTc relationship) and nonclinical data (e.g., difference 
between the hERG safety margin for the investigational drug and the threshold for 
defining low risk). If nonclinical studies do not show low risk (or are not performed), 
there is reluctance to conclude a lack of an effect in an absence of a positive control; 
however, if the upper bound of the two-sided 90% confidence interval around the 
estimated maximal effect on ΔQTc is less than 10 ms, the treatment is unlikely to have 
an actual mean effect as large as 20 ms. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 18/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
6.2 
March 
2014 
The ICH E14 Guideline does not address 
the approach to QT measurement during 
drug development in the case of 
combination drug products. Is it 
recommended that measurement of QT 
prolongation be performed on drug 
combinations? 
In general, combinations of two or more drugs are unlikely to need a thorough QT/QTc 
study or intensive late stage monitoring, if the component drugs have been 
demonstrated to lack relevant effects in thorough QT/QTc studies as described in ICH 
E14.  
If one or more of the component drugs have not been individually characterised for 
effects on the QT/QTc interval, they may be evaluated in combination or independently. 
6.3 
March 
2014 
Are sponsors expected to conduct 
thorough QT studies as part of the 
development of large proteins and 
monoclonal antibodies? 
Large targeted proteins and monoclonal antibodies have a low likelihood of direct ion 
channel interactions and a thorough QT/QTc study is not necessary, unless the potential 
for proarrhythmic risk is suggested by mechanistic considerations or data from clinical or 
non-clinical studies. 
7.  Electrocardiograms monitoring in late stage clinical trials 
#
 
 
Date of 
Approval 
Questions 
Answers 
7.1 
April 
2012 
The ICH E14 Guideline describes in 
Section 2.3 (Clinical Trial Evaluation 
After the “Thorough QT/QTc Study”) that 
“adequate ECG assessment to 
accomplish this [monitoring] is not fully 
established.” Is there now a reasonable 
approach to evaluating QTc in late stage 
clinical development in the case of a 
finding of QT prolongation prior to late 
phase studies? 
Clarification of approach to evaluating qtc in late stage clinical development 
The purpose of a thorough QT study is to characterize the effect of the drug on 
ventricular repolarization (QT interval). It is not the purpose of the thorough QT study to 
assess the risk of Torsade de Pointes (TdP) in the target population, but rather to 
determine whether further data are warranted to assess risk. A finding of QT 
prolongation above the regulatory threshold of interest (a positive thorough QT study) 
might call for further electrocardiographic follow up in late phase studies. The extent of 
the follow up would be affected by the magnitude of the estimated prolongation at doses 
and concentrations at which this occurs. If prolongation is substantial at concentrations 
expected to occur in clinical studies, it is important to protect patients in later trials and 
to obtain further information on the frequency of marked QT prolongation. In some cases 
in which there is a large margin of safety between therapeutic exposures and the 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 19/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
exposures that result in significant ECG interval changes, an intensive ECG follow-up 
strategy might not be warranted. 
 
The recommended intensity of the monitoring and assessment in latestage trials will 
depend on:  
A. The magnitude of QTc prolongation seen in the thorough QT study or early clinical 
studies.  
B. The circumstances in which substantial QT prolongation might occur (i.e., in ordinary 
use or only when drug concentrations are markedly increased [e.g., by renal or hepatic 
impairment, concomitant medications]).  
C. Pharmacokinetic properties of the drug (e.g., high inter-individual variability in plasma 
concentrations, metabolites).  
D. Characteristics of the target patient population that would increase the proarrhythmic 
risk (e.g., structural heart disease).  
E. The presence of adverse effects that can increase proarrhythmic risk (e.g., 
hypokalemia, bradycardia, heart block).  
F. Other characteristics of the drug (e.g., pharmacodynamics, safety pharmacology, 
toxicology, drug class, hysteresis). The following examples delineate the scope of 
recommended ECG investigations based on outcome of the thorough QT study or early 
clinical studies. These could be modified by other factors such as A-F above. 
 
Examples of ECG Monitoring in Late Stage: 
1. The thorough QT study results in a negative finding as defined by the E14 criteria* at 
the therapeutic dose, but the supratherapeutic dose (relative to Phase 3 dose) shows 
mean QTc effects between 10 and 20 ms. If there is reasonable assurance that the 
higher dose represents drug exposures that are unlikely to be seen in the patient 
population, only routine ECG monitoring is recommended in late phase trials. This 
approach provides reassurance for safety because patients are unlikely to experience 
a clinically significant QTc effect.  
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 20/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
2. The thorough QT study results in a positive finding as defined by the E14 criteria* at 
the therapeutic dose, with a mean prolongation <20 ms. For drugs with this 
magnitude of effect on the QTc interval, intensive monitoring of Phase 3 patients is 
called for. 
Intensive ECG monitoring in clinical trials has two main objectives. One objective is 
to provide protection to patients who might have large worrisome QT intervals >500 
ms. A second objective is identifying the frequency of marked QT increases (e.g., 
prolonged QT >500 ms or increases in QTc >60 ms).  
Given the limitations of collecting ECGs in late stage trials, the focus of the analysis 
is on outliers, not on central tendency. Other than descriptive statistics, detailed 
statistical analysis is not expected. This monitoring is intended to be performed 
locally, without the involvement of a central core laboratory.  
The timing of ECG collection should be based on the known properties of the drug. All 
patients should receive baseline, steady-state, and periodic ECGs during the trial. In 
addition, ECGs should be collected around Tmax at the first dose and/or around steady 
state in a subgroup of patients or in dedicated studies. ECG collection at around Tmax 
is not important for drugs with low fluctuations between peak and trough 
concentrations. If the drug shows a delayed effect in QT prolongation, then the 
timing of ECG collection should reflect this delay.  
3. The thorough QT study results in a negative finding as defined by the E14 criteria* at 
the therapeutic dose, but the supratherapeutic dose shows a mean effect between 10 
and 20 ms. If supratherapeutic exposure is anticipated at the clinical dose only in a 
well-characterized subgroup, intensive monitoring as described in Example 2 above 
could be carried out in this subset of the Phase 3 population. In this case, there 
should be reasonable assurance that the higher exposure is unlikely to be seen in the 
general patient population. In contrast, if people in the general patient population 
(who can not be readily identified in advance) will in some cases achieve this higher 
exposure, intensive ECG monitoring in the Phase 3 population is expected, as in 
Example 2.  
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 21/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
4. The therapeutic dose results in a mean QTc prolongation of >20 ms. For drugs with 
large QTc prolongation effects, intensive ECG assessment would be appropriate in all 
patients in Phase 2/3. Because of the risk of TdP, another important use of ECG 
monitoring in late phase trials would be to assess any risk mitigation strategies (e.g., 
electrolyte monitoring, dose reduction strategies). Additional ECG assessment over 
and above what is recommended earlier in the Q&A might also be called for (e.g., 24 
hour ECG recording, telemetry, multiple trough ECGs through steady state).  
The sponsor is encouraged to discuss these approaches with the relevant regulatory 
agency(ies) prior to initiation of the Phase 3 program.  
*A negative study as defined by the ICH E14 criteria is an upper one-sided 95% CI of 
QTc prolongation effect 
 
 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 22/37 
 
S7B Q&As 
1.  Integrated risk assessment 
#
 
 
Date of 
Approval 
Questions 
Answers 
1.1 
 
What is the general strategy for use of 
nonclinical information as part of an 
integrated risk assessment for delayed 
ventricular repolarization and torsade de 
pointes that can inform the design of 
clinical investigations and interpretation 
of their results? 
The ICH S7B guideline describes a nonclinical strategy for assessing risk of delayed 
ventricular repolarization and QT interval prolongation (Section 2.3). A mechanistic 
understanding of the development of torsade de pointes (TdP) and the emergence of new 
types of assays have made it possible to obtain more information to assess TdP risk from 
nonclinical assays. 
The in vitro IKr/hERG assay and in vivo QT assay as well as optional follow-up studies, as 
described by the ICH S7B guideline, are conducted for hazard identification and risk 
assessment relevant to delayed ventricular repolarization. It is generally accepted that 
drugs (note that the word “drug(s)” in the Q&As is used interchangeably with word 
“pharmaceutical(s)” in ICH S7B) that delay ventricular repolarization may have increased 
risk of TdP. 
1. To predict whether or not the hERG block poses a risk of interfering with ventricular 
repolarization or TdP, evaluation of the hERG safety margin based on results of a 
best practice assay (see S7B Q&As 1.2 and 2.1) is recommended. ICH S7A Section 
2.6 describes considerations for when human metabolite(s) should be assessed with 
in vitro systems. In these cases, the metabolite’s hERG safety margin should also be 
evaluated. 
2. In the in vivo study, the effects on the QTc interval should be assessed at exposures 
that cover the anticipated high clinical exposure scenario. The adequacy of exposure 
to any major human metabolites should be determined (see ICH S7A Sections 
2.3.3.2 & 2.6, and S7B Q&A 3.5). In addition, if the assay is to be used as part of an 
integrated clinical and nonclinical risk assessment for situations where a conventional 
thorough QT study is not feasible as described in ICH E14 Q&A 6.1, the in vivo study 
should have sufficient sensitivity to detect a QTc prolongation effect of a magnitude 
similar to dedicated clinical QT studies (see ICH S7B Q&A 3.4). This additional 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 23/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
consideration (sensitivity similar to dedicated clinical QT studies) does not apply to 
decision making prior to First-in-Human studies or under ICH E14 Q&A 5.1.  
 
A drug with low TdP risk would be expected to have (1) a hERG safety margin higher 
than a threshold defined based on the safety margins computed under the same 
experimental protocol for a series of drugs known to cause TdP (see ICH S7B Q&A 1.2 for 
additional details); and (2) no QTc prolongation in an in vivo assay of sufficient 
sensitivity conducted at exposures of parent compound and major human metabolites 
that exceed clinical exposures. See ICH S7A Sec. 2.6 for considerations of human 
metabolite(s) in the in vitro or in vivo nonclinical assays. If these results are used to 
support an integrated clinical and nonclinical risk assessment strategy as described in 
ICH E14 Q&As 5.1 & 6.1, no additional nonclinical studies are needed. When there are 
factors that can confound or limit the interpretation of the nonclinical studies, such as 
metabolites and heart rate changes, follow-up studies as described by ICH S7B (Section 
2.3.5) can be performed to address these specific issues. 
If the hERG assay and/or the in vivo QT study suggest an effect at clinical exposures, the 
drug has a risk of interfering with ventricular repolarization. Under this scenario, the 
drug’s TdP risk could be affected by various other factors, such as blocking of additional 
repolarization currents (e.g., IKs), blocking of inward currents (e.g., sodium and L-type 
calcium currents), effects on the trafficking of ion channel proteins from cytoplasmic sites 
to the surface membrane, metabolites with ion channel activities, and non-ion channel 
mediated QT prolongation. Follow-up studies (ICH S7B Section 2.3.5) could be 
performed to further explore the mechanisms and assess the TdP risk. If applicable, best 
practice considerations should be followed for assessment of additional ion channel 
currents (S7B Q&A 2.1), in vitro cardiomyocyte assays (S7B Q&As 2.2–2.5), or in vivo 
studies (S7B Q&As 3.1–3.5). An appropriately qualified proarrhythmia risk prediction 
model (see S7B Q&As 4.1–4.2) could be used according to its context of use to assess 
the possibility of TdP in humans. Use of in vitro and in silico models can reduce animal 
use in follow-up studies in accordance with the 3R (reduce/refine/replace) principles. The 
assessment of TdP risk using these follow-up studies, although optional, can be used 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 24/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
together with other relevant nonclinical and clinical information to contribute to the 
design of subsequent clinical investigations and interpretation of their results. 
1.2 
 
What is the recommended method to 
compute the hERG safety margin? 
A drug’s potency for hERG block, usually calculated as half-inhibitory concentration 
(IC50), can be normalized to the drug’s estimated clinically relevant exposures in patients 
to calculate the safety margin. As more information is obtained during the clinical 
development, the estimated values of clinical exposures can be refined. When estimating 
hERG block potency, it is recommended to use standardized procedures and to consider 
the principles described in S7B Q&A 2.1.  
The free drug exposure is computed based on the drug’s total plasma concentration and 
the fraction of protein binding. Because of uncertainties in the protein binding 
measurements, the unbound (free) fraction in plasma should be set to 1% if 
experimentally determined to be < 1%. This approach has been used in the regulatory 
assessment for the risk of drug-drug interactions. If protein binding values cannot be 
accurately assessed (e.g., questionable validation of the bioanalytical method, deviations 
from best practices), safety margins should be calculated for both steady-state free and 
total Cmax.  
In terms of the exposure to use in the denominator of the safety margin calculation for 
supporting decision making under ICH E14 Q&As 5.1 or 6.1, it is generally recommended 
to use the high clinical exposure as defined in ICH E14 Q&A 5.1 (i.e., mean steady state 
maximum concentration [Cmax,ss] when the maximum therapeutic dose is administered in 
the presence of the intrinsic or extrinsic factor that has the largest effect on increasing 
Cmax,ss).  
To assess whether the hERG block poses a risk of delaying ventricular repolarization or 
TdP, the resulting safety margin should be compared to the range of safety margins 
computed under the same experimental protocol for a series of reference drugs that 
have known clinical TdP risk and cover diverse electrophysiological properties. Additional 
pharmacological principles or modeling can be used to justify the use of a certain safety 
margin threshold (e.g., relationship between hERG block and QTc prolongation from 
semi-mechanistic pharmacokinetic/pharmacodynamic models or systems pharmacology 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 25/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
models; see Leishman et al. J Pharmacol Toxicol Methods 2020 
[https://doi.org/10.1016/j.vascn.2020.106900], for examples). This should be supported 
by experimental data based on the principles in these Q&As (e.g., same experimental 
protocol applied to a series of drugs with known clinical TdP risk).  
Data supporting the safety margin threshold to define a drug as having low TdP risk 
should be supplied in or appended to the submitted study report. If a recommended 
hERG margin threshold is published based on principles in these Q&As, a sponsor (or a 
contract laboratory) seeking to use the same threshold should demonstrate that the 
inter-laboratory variability of IC50s from a set of calibration drugs under the same 
experimental protocol does not significantly decrease the sensitivity of the safety margin 
threshold for detecting drugs that are not low risk for TdP. Appropriate statistical 
methods should be applied to quantify experimental IC50 variability and calculate 
uncertainty of the safety margin as confidence/credible intervals. 
 
2.  Best practice considerations for in vitro studies 
#
 
 
Date of 
Approval 
Questions 
Answers 
2.1 
 
What are some “best practice” 
considerations when evaluating drug 
potency on affecting cardiac ionic 
currents using patch clamp method and 
overexpression cell lines?  
As outlined in ICH S7B, the in vitro IKr/hERG assay plays a critical role in assessing the 
risk for delayed repolarization and QT interval prolongation prior to first administration in 
humans. Nonclinical investigations can also contribute to an integrated risk assessment 
in later stages of development when clinical QT data are available. The following “best 
practice” aspects should be considered when sponsors are using IKr/hERG data to support 
interpretation of clinical QT data in specific scenarios as described in S7B Q&As 1.1 & 1.2 
and ICH E14 Q&As 5.1 & 6.1, and when using CaV1.2 and NaV1.5 to support a 
proarrhythmia assessment (ICH S7B Q&As 1.1). It is not the intent of these Q&As to 
make specific recommendations for a sponsor’s screening activities or for all IKr/hERG 
assays to support first administration in humans. 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 26/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
Several experimental factors are known to influence the potency of drug effects on 
cardiac ionic currents. These include the voltage protocols used to evoke specific ionic 
currents, experimental conditions (such as recording temperature, composition of 
solutions, manual vs. automated assay systems), data acceptance criteria, and data 
analysis methods employed. Some recommended best practices are therefore provided 
to enhance reproducibility of in vitro results and the translation to clinical findings. These 
recommendations are generalizable to voltage clamp experiments characterizing potency 
of drug inhibition (or potentiation) of cardiac currents. 
1. Recording temperature: The effects of some drugs are temperature-sensitive and 
there is currently no method to predict which molecules exhibit temperature-
dependent effects or the magnitude of these effects. Thus, patch clamp experiments 
on cells overexpressing cardiac ion channels, including hERG, CaV1.2, and NaV1.5, 
should be performed at near physiological temperature (35–37 °C).  
2. Voltage protocol: The voltage protocols used to evoke ionic currents should 
approximate the appropriate elements of a ventricular action potential and be 
repeated at frequencies that are sufficient to minimize the possibility of missing the 
effects of a test drug at physiologically relevant heart rates. For hERG, a stimulation 
frequency of 0.2 – 1 Hz is recommended. For CaV1.2 and NaV1.5 currents, a 
stimulation frequency of 0.2 Hz is recommended. The voltage protocol should include 
steps that enable monitoring of cell health and consistent electrophysiological 
recordings throughout the experiment (i.e., estimation of input and series resistance 
across time). If high seal resistance is achieved, holding current and input resistance 
(i.e., measures of passive membrane properties at rest) can be used as indicators of 
cell health and experimental stability. After application of the test drug and if 
recording quality remains acceptable, a saturating concentration of a selective 
blocker should be applied to cells to determine residual background current in 
individual cells. If prominent, background current should be factored into potency 
determinations.  
3. Recording quality: Seal resistance should be high enough so that the leak 
conductance at all voltages specified by the voltage protocol and series resistance do 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 27/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
not compromise voltage control. The extent of series resistance compensation 
applied to optimize voltage control should be noted. Stability of the ionic current 
should be demonstrated with baseline recordings (prior to drug application) of 
sufficient duration to characterize drug-independent changes (such as current 
rundown). The time course of drug effects should be monitored until steady state 
effect is obtained, and each cell can be exposed to one or more drug concentrations 
as long as cell health and recording quality remain stable.  
4. Primary endpoint measures: The primary derived endpoints are inhibitory 
concentration such as the IC50 value (reported in both micromolar and ng/mL units) 
and Hill coefficient. If 50% current inhibition could not be achieved, a justification of 
the highest concentration tested should be provided together with the relation of this 
concentration to therapeutic free and total drug levels. Where necessary, to isolate 
the current-of-interest, the background current remaining after a high concentration 
of selective blocker application should be subtracted. If current inhibition with a 
selective blocker could not be achieved, leak current can be calculated and 
subtracted from the current traces. This approach assumes that only the current-of-
interest is voltage-dependent, hence evidence and justification should be provided on 
why it was used. 
5. Data summary: Inhibition at each drug concentration for each cell should be 
provided, along with the mean values of IC50 and Hill coefficient (and appropriate 
measures of data variability). To demonstrate recording quality, the study report 
should also contain time-course plots of current amplitude, input resistance, holding 
current for individual cells in control condition followed by drug application, and drug 
equilibration. If time-dependent changes such as current run-up or run-down in 
baseline condition were corrected for drug inhibition estimation, the correction 
method applied should be described.  
6. Concentration verification: The concentration of test compound to which the cells 
were exposed should be verified by applying a validated analytical method to the 
solution collected from the cell chamber. Both nominal and measured concentrations 
should be reported. If the nominal and measured concentrations differ significantly 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 28/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
from each other, measured concentrations should be used to construct the 
concentration-response relationship to estimate IC50 and Hill coefficient.  
7. Positive and negative controls: The positive control drug should be one of the 
“reference drugs” referred to in Q&A 1.2. The positive control drug should be tested 
using sufficient replicates and two or more concentrations achieving 20-80% block, 
to demonstrate consistency and reproducibility with the reference drug data. If 
positive control data fall outside the range of expected values, then the study is 
inconclusive, and it would not be recommended that the data be used to support the 
purposes outlined in ICH E14 Q&As 5.1 and 6.1. Vehicle (negative) controls should 
be included in the experiments. The vehicle should include all non-compound 
materials in the test article solution such as solubilizing agents and preservatives. 
2.2 
 
What are the relevant endpoints of an 
informative in vitro human 
cardiomyocyte repolarization followup 
study? 
As outlined in ICH S7B, follow-up studies (Section 2.3.5) can include in vitro ventricular 
repolarization assays. Follow-up studies are not performed for all submissions and are 
often designed to address specific issues. Since implementation of ICH S7B, new 
technologies have become available, including assays with human induced pluripotent 
stem cell derived cardiomyocytes (hiPSC-CMs). S7B Q&As 2.2–2.5 outline best practice 
considerations when in vitro cardiomyocyte assays are performed as follow-up studies.  
Drug-induced changes in the intracellular or extracellular action potential waveforms 
recorded from hiPSC-CM preparations and acutely isolated adult human ventricular 
myocytes reflect the integrated effect on multiple ionic currents, exchangers, and 
carriers. Changes in cellular repolarization recognized as markers of ventricular 
proarrhythmia include delayed and abnormal repolarization (manifest as early 
afterdepolarizations, triggered activity or irregular beating) and should be noted.  
Drug induced effects on cardiomyocyte calcium handling (calcium transients, 
contractility, or calcium homeostasis) could affect electrophysiological activity. These 
effects may manifest as abnormal mechanical activity associated with proarrhythmic 
mechanisms (e.g., prolonged contractions, single or multiple premature contractions 
linked to triggered electrical activity such as early afterdepolarizations). The assessment 
of changes in calcium handling is useful for describing the presence or absence of 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 29/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
potential proarrhythmic activity. However, such measures are inadequate to fully 
characterize the electrophysiological effects of a drug on repolarization. 
2.3 
 
What elements of the test system need 
to be considered for an in vitro human 
cardiomyocyte repolarization assay? 
It is important to describe the biological preparation and technology platform that define 
baseline electrophysiological characteristics and drug responses. 
• 
Biological preparation: The origins of cells studied, and human donor characteristics 
should be specified. If complex preparations containing hiPSC-CMs are used (e.g., 
co-cultures, organoids, engineered heart tissues), descriptions of the protocols used 
in creating these preparations should be provided. For primary human cardiomyocyte 
preparations, the tissue sources, harvesting, isolation, and enrichment procedures 
followed should be described. Acceptable morphological and functional inclusion 
criteria for the preparations as well as electrophysiologic characteristics (including 
baseline action potential/field potential durations, spontaneous beat frequency and 
variability [if applicable], resting membrane potential, upstroke characteristics, 
conduction patterns and/or velocity) should be clearly defined. Estimates of the 
proportion of preparations fulfilling criteria should be included.  
• 
Technology platform: The methodologies used (e.g., transmembrane potential 
recordings [whole cell patch clamp, sharp electrode, or voltage-sensing dye 
approaches], extracellular recordings using field potentials, visual or impedance-
based motion approaches, or calcium-sensing dyes) should be clearly described. The 
analysis package used for marking and interpreting waveforms should be described, 
with representative recordings (along with pertinent waveform markings) provided. A 
description of the plates or chambers used (including presence or absence of flow, 
substrate composition, recording electrode characteristics) should be provided. 
2.4 
 
What are important considerations when 
designing and implementing 
experimental protocols for in vitro 
cardiomyocyte repolarization studies? 
Protocols should be designed to address a specific question (e.g., concentration-
dependent effects on repolarization). The rationale of choosing a single- or sequential-
dose protocol should be provided. Bath temperature should be stable at physiologic (35–
37 ºC) temperature. The sampling “window” for data collection should be clearly defined. 
Deviations from protocols should be clearly described, along with expected 
consequences.  
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 30/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
• 
For spontaneously beating preparations, changes in beating rate influence 
repolarization independent of direct drug effects on repolarizing currents. 
Spontaneous beat rates in the absence and presence of drugs should be clearly 
indicated along with the extent of drug-induced rate changes. The choice and 
justification of correction formula used when assessing repolarization effects in such 
preparations should be provided. Due to limitations of rate correction in 
spontaneously beating hiPSC-CMs, interpretation of potential repolarization changes 
may not be possible when a drug causes a rate change.  
• 
For paced preparations, the pacing protocol (pattern and duration) should be 
described and performed in the presence and absence of test compound.  
• 
To demonstrate recording quality, the study report should contain time-course plots 
of primary endpoints (demonstrating drug equilibration) and other parameters that 
can be used to infer stability of the preparations and signal recordings.  
• 
Concentration-dependent repolarization effects can be derived based on vehicle-
corrected and/or baseline subtracted comparisons of drug vs. vehicle treated 
preparations. For higher throughput multi-well platforms, it is preferable to conduct 
vehicle and test drug studies on the same plate. The number of replicates (useful for 
evaluating reproducibility but not inferential statistical testing) should be reported. 
Power calculations are helpful to establish statistical sensitivity to repolarization 
endpoints.  
• 
It is important to characterize drug exposures during in vitro cardiomyocyte 
repolarization studies. For well-based studies, drug exposures could be verified using 
media sampled from test wells or from “satellite studies” (parallel studies using 
identical protocols and study conditions conducted without measuring 
electrophysiologic measurements). With continuous flow systems the sampling of 
effluent from test chambers is valuable for assessing drug exposures. Exposures 
should be presented as total drug concentration and free drug concentrations (if 
plasma protein binding characteristics in the media used is known).  
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 31/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
2.5 
 
How does one define biological 
sensitivity of a cardiomyocyte in vitro 
repolarization assay? 
The electrophysiologic sensitivity of cardiomyocyte preparations should be calibrated with 
established positive controls to confirm their “fit for purpose” role in defining 
pharmacological block of cardiac ion channel(s). This is readily accomplished by 
constructing concentrationresponse curves with recognized and specific ion current 
blocking agents.  
• 
At minimum, it is important to characterize sensitivity to block of the prominent 
outward repolarizing current IKr/hERG with specific blocking agents (e.g., E-4031 or 
dofetilide) over relevant concentration ranges.  
• 
• Block of the inward L-type calcium current (ICaL) and late sodium current (INaL) may 
mitigate delayed repolarization. Demonstrating sensitivity to specific ICaL (e.g., 
nifedipine or nisoldipine) and INaL (e.g., mexiletine or lidocaine) blocking agents is 
helpful for clarifying integrated cellular electrophysiological responses of multi-
channel blocking drugs. 
3.  Best practice considerations for the in vivo QT studies 
#
 
 
Date of 
Approval 
Questions 
Answers 
3.1 
 
What are best practice considerations for 
species selection and general design of 
the (standard) in vivo QT study? 
The most appropriate species should be selected and justified (ICH S7B, Section 3.1.3). 
It is preferable to use the same animal species in the safety pharmacology and non-
rodent toxicity studies to facilitate understanding of the possible relationship between 
adverse cardiovascular pharmacodynamic effects and structural effects on the heart, and 
to obtain complementary information on systemic exposure level (toxicokinetics).  
While it is customary to use conscious freely moving telemeterized animals for the in vivo 
QT studies, the choice of alternative model approaches (e.g., anesthetized or paced 
animals) might be justified in certain circumstances to achieve adequate exposures or to 
overcome specific compound-related challenges (e.g., changes in heart rate, tolerability, 
or bioavailability limitations in conscious animals). 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 32/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
3.2 
 
What should be considered for exposure 
assessment during the in vivo QT study? 
The ICH S7B guideline states that drug exposures should include and exceed anticipated 
therapeutic concentrations. If the in vivo QT data are to be used as part of an integrated 
risk assessment for situations described in ICH E14 Q&As 5.1 & 6.1, the exposure should 
cover the anticipated high clinical exposure scenario (see S7B Q&A 1.1). An assessment 
of exposure in the same animals used for the pharmacodynamic assessment is 
encouraged. Sampling should take place at relevant timepoints and in a manner that 
limits interference with the pharmacodynamic effects. This could be done by sampling 
complete pharmacokinetic profiles in the same animals on a separate day after an 
adequate washout or different animals. At least one pharmacokinetic sample should be 
obtained during the pharmacodynamic assessment day to demonstrate consistency with 
the full pharmacokinetic profiles. In certain cases, the analysis of QTc interval together 
with adequate pharmacokinetic sampling makes it possible to perform dedicated 
exposure-response modeling similar to concentrationQT analysis for clinical QT studies. 
This can be helpful when the study should be powered to detect an effect similar to 
dedicated QT studies in humans (e.g., when using in vivo QT data as part of an 
integrated nonclinical and clinical risk assessment as described in ICH E14 Q&A 6.1) as it 
can reduce the number of animals in accordance with the 3R (reduce/refine/replace) 
principles. In addition, exposure-response modeling may be helpful in other 
circumstances when QT prolongation is observed or anticipated based on hERG assay 
results.  
3.3 
 
What information is needed to support 
the choice of heart rate correction 
method in an in vivo QT assay? 
Optimally, the sponsor should demonstrate the independence of QTc to RR intervals 
observed in the study through QTc versus RR plots accompanied by additional 
information (e.g., number of matched QTc-RR pairs, correlation metric, 95% confidence 
intervals, p-values). QT-RR interval relationship is also important. Justification of 
correction factors used for QT measures should be provided when test drugs affect heart 
rate. In certain cases, individual QT correction based on QT-RR relationship is a preferred 
method as it is more accurate and sensitive than the general methods such as Bazett, 
Fridericia, or Van de Water when the test drugs affect heart rate. The main reason for 
not using correction formulae based on historical data is the fixed rate correction 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 33/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
coefficients. Non-rodent species show species-specific and individual differences in their 
QT-RR relationships. 
3.4 
 
How should the sensitivity of the assay 
be evaluated? 
The test system used for an in vivo QT assay should provide a robust response. Assay 
sensitivity of relevant functional endpoints should be evaluated and reported to enable 
data interpretation (in supporting initiating first-in-human studies and/or an integrated 
nonclinical and clinical integrated risk assessment to be applied under the scenarios in 
ICH E14 Q&As 5.1 or 6.1) and contextualization. Demonstration of assay sensitivity can 
be achieved by defining minimum detectable differences and testing the effects of 
positive controls. Statistical power calculations could also be provided from historical 
data from the same laboratory using the identical protocol. If historical positive control 
data are utilized to justify assay sensitivity or statistical power is calculated from 
historical control data, then the variance of the present data should be consistent with 
that seen historically. 
If study results are to be used to support an integrated nonclinical and clinical risk 
assessment described in ICH E14 Q&A 6.1, then the study should have sensitivity to 
detect a QTc prolongation effect of a magnitude similar to dedicated clinical QT studies, 
taking into consideration interspecies differences in the normal range of values for the 
QTc interval. The overall sensitivity of the nonclinical assay in comparison to clinical QT 
studies depends on both the electrocardiographic assessment and the exposure achieved 
in the in vivo assay relative to high clinical exposure. This can help reduce the numbers 
of animals used in accordance with the 3R (reduce/refine/replace) principles. The 
following hypothetical example is offered for consideration with recognition that the QTc 
threshold and exposure multiples selected for a particular study should be justified by 
data obtained in the specific species tested, using recognized reference compounds 
under conditions consistent with the best practice recommendations set forth in these 
Q&As.  
• 
Hypothetical Example: The minimal detectable difference might be 5 milliseconds if 
drug exposure in the animal study only covers the high clinical exposure but might 
be higher if a larger multiple of high clinical exposure is achieved (e.g., 10 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 34/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
milliseconds if 3X high clinical exposure is achieved; or a higher QTc threshold if an 
even larger multiple is achieved). 
3.5 
 
What are the recommended conventions 
for presenting the pharmacodynamic and 
pharmacokinetic results of an in vivo QT 
assay?  
To facilitate the regulatory review of an in vivo QT assay, the following are general 
recommendations. 
Pharmacodynamic Content  
• 
Summary tables and figures showing absolute mean values, mean percent change 
from baseline, confidence intervals, and p-values for changes from baseline and 
vehicle control should be included.  
• 
If study results are being used to support ICH E14 Q&A 6.1, then data from positive 
controls should be included or appended. If historical positive controls are used, then 
the variance of the present data should be consistent with that seen historically, 
which can be demonstrated by reporting minimal detectable differences with by time 
analysis. A statement should be provided that the data for the new drug and the 
historical data were collected according to the same protocol and statistical analysis 
plan. If deviations are present, they should be clearly justified. If concentration-QTc 
modeling is performed, reporting should follow similar principles as for human 
concentration-QTc modeling (see ICH E14 Q&A 5.1).  
Pharmacokinetic Content  
• 
Tabulations of summary statistics for Cmax, AUC, and Tmax for the parent drug and 
metabolites along with plasma concentration vs. time plots (if sufficient samples 
have been collected to support their calculation) should be provided.  
Individual animal data should be provided. 
 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 35/37 
 
4.  Principles for proarrhythmia models 
#
 
 
Date of 
Approval 
Questions 
Answers 
4.1 
 
The ICH S7B guideline (Section 3.1.4) 
states that directly assessing the 
proarrhythmic risk of pharmaceuticals 
that prolong the QT interval would be a 
logical undertaking and interested 
parties are encouraged to develop these 
models and test their usefulness in 
predicting risk in humans. What are 
general principles to evaluate whether a 
proarrhythmic risk prediction model 
could be used as part of an integrated 
risk assessment strategy? 
Different models, including in silico, in vitro, ex vivo and in vivo models, have the 
potential to be used as part of an integrated risk assessment strategy to evaluate the 
proarrhythmic risk of QT-prolonging pharmaceuticals in humans. Use of in vitro and in 
silico models can also reduce animal use in accordance with the 3R 
(reduce/refine/replace) principles. Because these models have a common feature of 
using nonclinical experimental data as input and generating human proarrhythmia risk 
prediction as output, they can generally be referred to as proarrhythmia risk prediction 
models. The model input can vary among different models, for example, ion channel 
pharmacology data as input to in silico models, drug-induced changes in cellular 
repolarization and/or arrhythmia events as input to hiPSC-CM models, and druginduced 
electrocardiographic changes as input to ex vivo/in vivo models. However, the model 
output (either discrete risk categories or continuous risk scores) is similar among 
different models. Such a feature makes it possible to develop generic principles for 
evaluating the predictivity of proarrhythmia risk prediction models without specifying the 
type of underlying experimental data used as model input. The following general 
principles should be applied to all proarrhythmia risk prediction models intended to be 
used as part of an integrated risk assessment for regulatory purposes. While the main 
focus of these principles is to evaluate a model’s predictivity of TdP risk, they are general 
enough to guide the development of models predicting different types of proarrhythmia. 
1. A defined endpoint consistent with the context of use of the model. Examples of 
model endpoints (e.g., TdP risk vs QT prolongation risk) can be found in Li et al. Clin 
Pharmacol Ther 2020 (https://doi.org/10.1002/cpt.1647).  
2. A fully disclosed algorithm to translate experimental measurements (model input) to 
proarrhythmia risk (model output), allowing independent reproduction of the model 
development process using the associated training and validation datasets to 
evaluate the model performance.  
3. A defined domain of applicability/ scope and limitations of the model. This includes 
the experimental protocols to generate model input (experimental data capturing 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 36/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
pharmacological effects of drug), and the compounds tested should have the same 
arrhythmic mechanisms covered by the model.  
4. A prespecified analysis plan and criteria to assess model predictivity. The analysis 
plan should include methods to separate the training and validation steps. In the 
training step, a series of reference compounds is used to adjust the model. In the 
validation step, another series of reference compounds is used to evaluate the 
performance of the pre-specified model. The reference compounds used for the 
training and validation steps should not overlap.  
5. A mechanistic interpretation of the model, which describes the relationship between 
the model inputs and mechanism for the arrhythmia.  
6. The uncertainty in the model inputs should be captured and propagated to the model 
predictions. The experimental variability associated with model input should be 
quantified using appropriate statistical methods and then translated into probabilities 
of the predicted risk. 
After a proarrhythmia risk prediction model has been developed, a process should be 
followed to evaluate whether the model development complied with these principles. 
Such a process would support that the model is qualified for the intended context of use 
as part of an integrated risk assessment for regulatory purposes. Some health authorities 
have procedures for the formal qualification of models that allow for a model to be used 
within the qualified context of use without the regulatory authority needing to reconsider 
and reconfirm its suitability. Model developers are encouraged to contact a regulatory 
agency about its specific model qualification procedures. After a model has been 
qualified, the use of such a model is not limited to the specific facility that submitted the 
qualification package. However, if another facility intends to use the qualified model, that 
facility should perform laboratory-specific calibration and validation of the model using a 
subset of the reference compounds that were originally used to develop the model. An 
illustrative process of performing laboratory-specific calibration and validation is given in 
Han et al. J Pharmacol Toxicol Methods 2020 
(https://doi.org/10.1016/j.vascn.2020.106890). 
 
 
ICH guideline E14/S7B: clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential - 
questions and answers  
 
EMA/CHMP/ICH/415588/2020  
Page 37/37 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
4.2 
 
How can a sponsor use a model for 
regulatory submission and what are the 
limitations? 
Sponsors can use results from a qualified proarrhythmia model as one component in the 
totality of evidence approach to risk assessment under the context of use for which the 
model was developed and qualified. When a facility intends to use the model to produce 
data for regulatory submission, a set of control compound(s) should be tested to assess 
the consistency between the new data and the historical laboratory-specific validation 
data. The number and type of laboratory-specific calibration and control compounds 
should be justified.  
If a proarrhythmia model is included in a regulatory submission, proof of qualification of 
the model under the guidance of the general principles in this Q&A should be provided in 
an appendix to the study report. Supportive documentation could include published 
papers, if the included validation dataset is described in sufficient detail to allow an 
independent assessment. Importantly, the general principles for model qualification set 
forth in this Q&A only support the use of a proarrhythmia risk prediction model as part of 
an integrated risk assessment that incorporates all relevant nonclinical and clinical 
information. 
 
 
 