European Medicines Agency 
Evaluation of Medicines for Human Use 
 
 
7 Westferry Circus, Canary Wharf, London, E14 4HB, UK 
Tel. (44-20) 74 18 84 00   Fax (44-20) 74 18 85 45 
E-mail: mail@emea.eu.int     http://www.emea.eu.int 
©EMEA 2008 Reproduction and/or distribution of this document is authorised for non commercial purposes only provided the EMEA is acknowledged 
  
London, 24 July 2008 
 
Doc. Ref. EMEA/CHMP/BWP/398498/2005 
CHMP/BWP  
(COMMITTEE ABBREVIATION) 
GUIDELINE ON VIRUS SAFETY EVALUATION OF BIOTECHNOLOGICAL 
INVESTIGATIONAL MEDICINAL PRODUCTS 
 
DRAFT AGREED BY BWP 
May 2006 
ADOPTION BY CHMPFOR RELEASE FOR CONSULTATION 
28 June 2006 
END OF CONSULTATION (DEADLINE FOR COMMENTS) 
31 December 2006 
AGREED BY BWP 
June 2008  
ADOPTION BY CHMP 
24 July 2008 
DATE FOR COMING INTO EFFECT 
1 February 2009 
 
 
KEYWORDS 
Virus safety, clinical trial, investigational medicinal products, IMPs 
 
 
 
©EMEA 2008  
 
 
 
          Page 2/9 
 
 
GUIDELINE ON VIRUS SAFETY EVALUATION OF BIOTECHNOLOGICAL 
INVESTIGATIONAL MEDICINAL PRODUCTS 
TABLE OF CONTENTS 
EXECUTIVE SUMMARY................................................................................................................... 3 
1. 
INTRODUCTION......................................................................................................................... 3 
2. 
SCOPE............................................................................................................................................ 3 
3. 
LEGAL BASIS .............................................................................................................................. 3 
4. 
MAIN GUIDELINE TEXT .......................................................................................................... 3 
4.1 
GENERAL PRINCIPLES.............................................................................................................. 3 
4.2 
ASSURING THE VIRAL SAFETY OF BIOTECHNOLOGICAL IMPS ................................................ 4 
4.2.1 
Cell line qualification: testing for viruses ..................................................................... 4 
4.2.2  
Raw materials of biological origin................................................................................. 4 
4.2.3 
Testing for viruses in unprocessed bulk ........................................................................ 4 
4.2.4 
Validation of virus reduction ......................................................................................... 5 
4.2.5 
Description and Qualification of Analytical Procedures.............................................. 7 
4.3 
VIRUS SAFETY RISK ASSESSMENT............................................................................................ 8 
4.4 
RE-EVALUATION OF VIRAL SAFETY DURING DEVELOPMENT .................................................. 8 
4.5 
FORMAT OF CLINICAL TRIAL AUTHORISATION DOCUMENTATION........................................... 8 
REFERENCES (SCIENTIFIC AND/OR LEGAL) ........................................................................... 9 
 
 
©EMEA 2008  
 
 
 
          Page 3/9 
 
EXECUTIVE SUMMARY 
The purpose of this document is to provide scientific guidance relating to the viral safety of 
biotechnological medicinal products used in clinical trials. Guidance is provided with respect to: 
(i) 
the criteria for and the extent of viral safety evaluation studies, that are required prior to and 
during clinical development.   
(ii) 
the extent to which manufacturers are able to refer to in-house experience concerning virus 
safety evaluation.   
(iii) 
the risk assessment which should form part of the safety evaluation. 
 
1. 
INTRODUCTION 
Assuring the viral safety of biotechnological medicinal products is a complex process and a reliable 
assessment of the viral safety of an investigational medicinal product (IMP) is critical. 
This guideline provides advice on the viral safety data and documentation that should be submitted in 
a request for authorisation of a clinical trial of a human biotechnological medicinal product. Reference 
is made to ICH Q5A (see references), which defines data requirements for marketing authorisation 
applications (MAA). Although Q5A does not provide specific guidance for biotechnological products 
in clinical development, the basic principles remain pertinent and applicable. 
The guideline provides for a harmonised approach throughout the European Union, for both sponsors 
and regulators, with regard to assessment of viral safety of biotechnological IMPs during clinical 
development.  This will be especially beneficial for multi-centre studies, potentially involving several 
different member states.  
2. 
SCOPE 
This guideline applies to human biotechnological IMPs prepared from cells cultivated in vitro from 
characterised cell banks of human or animal origin as described in Q5A.  Many IMPs are derived from 
well-characterised rodent cell lines such as CHO, NS0 or SP2/0, although a variety of other cell lines 
are in use and under development and should be considered on a case-by-case basis. 
The guideline covers monoclonal antibodies and recombinant DNA derived IMPs including 
recombinant subunit vaccines.  It does not apply to IMPs that contain recombinant viruses or bacteria 
(both replicative and non-replicative), or live attenuated or inactivated vaccines.  IMPs derived from 
hybridoma cells grown in vivo are also excluded from the scope of this guideline. 
This guideline outlines the viral safety requirements applicable to all stages of clinical development of 
an IMP.  The guideline does not apply to IMPs to be used solely for non-clinical testing.   ICH Q5A 
provides guidance on data required to support MAAs. 
3. 
LEGAL BASIS 
Clinical trials within the EU are regulated by Directive 2001/20/EC (see references) and 
investigational medicinal products used in trials should be manufactured according to the principles of 
Good Manufacturing Practice Approval of trials is the responsibility of individual Member States, 
which are required to evaluate the products used in clinical studies. 
4. 
MAIN GUIDELINE TEXT 
4.1 
General Principles 
The aim of virus safety studies for biotechnological IMPs is to demonstrate an acceptable level of 
safety for clinical trial subjects. 
The viral safety of a licensed biotechnological medicinal product is assured by three complementary 
approaches involving (i) selecting and testing cell lines and other raw materials of human or animal 
origin for viral contaminants, (ii) assessment of the capacity of downstream processing to clear 
 
©EMEA 2008  
 
 
 
          Page 4/9 
 
infectious viruses and (iii) testing the product at appropriate steps for contaminating viruses (see ICH 
Q5A).  
For a biotechnological IMP, due to the developmental nature of the manufacturing process and of the 
product, a reduced programme of studies on assuring viral safety is envisaged compared with the data 
requirements for marketing authorisation; firstly, for testing for viruses in end of production 
cells/unprocessed bulk (see Section 4.2.3) and secondly, for studies on the validation of virus 
reduction (see Section 4.2.4).  Such a reduced programme would only be applicable for cell lines 
classified in ICH Q5A as ‘Case A’ or ‘Case B’.  Demonstrated in-house experience (see Section 4.2.4) 
could also contribute to a reduced package of studies on virus reduction. 
In addition to the provision of data, a risk assessment should be made taking into account some or all 
of the following factors:  
• 
the nature and history of the cell line, 
• 
the extent of characterisation of the cell line, 
• 
use of raw materials of human and/or animal origin during manufacture and their control, 
• 
potential for product exposure to adventitious contamination, 
• 
experience of the manufacturer with the cell line involved, 
• 
experience of the manufacturer with specific virus reduction procedures to be used, 
• 
published data. 
4.2 
Assuring the viral safety of biotechnological IMPs 
4.2.1 
Cell line qualification: testing for viruses 
Testing of the master cell bank (MCB) for viral contaminants should be performed as described in 
Q5A prior to the initiation of a Phase I trial. 
A working cell bank (WCB) might only be set up during clinical development and thus, for some 
biotechnological IMPs being used early in clinical development, it may not yet have been established.  
When established, the first WCB should in principle be tested as outlined in ICH Q5A.  However, 
where unprocessed bulks are tested as described in Section 4.2.3/Table 1, testing of cells at the limit of 
in vitro cell age is not required. 
Since endogenous retroviral viruses or particles are present in most cell lines currently in use and there 
is a probability that they will be present in a novel cell line, particular attention should be paid to 
investigating the cell line for their presence. 
4.2.2  
Raw materials of biological origin 
The viral safety evaluation of biotechnological IMPs should take into account biological raw materials 
(especially animal or human derived) used in production.  A risk-based assessment focusing on the 
type and origin of the raw material, its process conditions and testing, as well as its use in the 
manufacture of the medicinal product and tests applied to the unprocessed bulk material, is an 
acceptable approach to the evaluation of its viral safety (see also Section 4.2.3). 
Appropriate documentation should be provided regarding the viral safety of raw material of biological 
origin.  Reference is made to guidance documents on bovine sera as well as on minimising the risk for 
transmission of animal spongiform encephalopathy (see references). 
4.2.3 
Testing for viruses in unprocessed bulk 
Independent of the stage of development, each batch of unprocessed bulk material that will be used to 
manufacture clinical trial material should be tested as per Q5A.  The sample to be tested should 
include cells, when appropriate, and tests should include in vitro and PCR-based screening tests for 
adventitious agents and an estimation of retroviral particles, where applicable.  No further testing is 
required for bulks deriving from CHO cell lines.  For manufacture based upon NS0 or Sp2/0 cell lines, 
tests for infectious retroviruses should be applied on a one-off basis but should be repeated if there is a 
significant change in production cell culture, e.g. manufacturing scale.  For manufacture based upon 
 
©EMEA 2008  
 
 
 
          Page 5/9 
 
any other cell line, tests for infectious retroviruses and in vivo tests (as per section 3.2.3 of ICH Q5A) 
should be applied on a one-off basis, but should be repeated if there is a significant change in 
production cell culture, e.g. manufacturing scale.  These testing recommendations are shown in 
Table 1.  Consideration should be given to the inclusion of a test for MMV if the cell line is 
permissive for this virus. 
The source and viral safety of the raw materials used during cell culture should be taken into account 
when devising the unprocessed bulk testing (see also Section 4.2.2).  Additional specific tests may be 
required if human or animal derived raw materials are used, e.g. bovine serum. 
Table 1.  Testing requirements for unprocessed bulks 
 
In vitro testing 
Tests 
for 
infectious 
retroviruses* 
In vivo testing* 
CHO 
Yes, all bulks§ 
No 
No 
NS0 and Sp2/0 
Yes, all bulks§ 
Yes, once for given 
scale 
No 
All other cell lines 
Yes, all bulks§ 
Yes, once for given 
scale 
Yes, once for given 
scale 
* Where possible, test material should contain cells or cellular fragments in order to detect cell-
associated viruses.  For perfusion cell cultures, manufacturers should determine and justify the most 
appropriate stage at which to derive samples containing cells for testing.   It is also acceptable to 
derive test material from cells that have been cultured beyond the scale used to generate the batch of 
product; in these circumstances, the approach taken should be justified.  Testing for infectious 
retroviruses may be omitted when more sensitive tests have shown negative results. 
§ Quantification of retroviruses or retroviral-like particles need only be performed for the first three 
bulks for a specific stage of development (or less, if less than three bulks are prepared). 
4.2.4 
Validation of virus reduction 
The objective of the validation is two-fold; firstly, to characterise and evaluate process steps that can 
be considered to be effective in inactivating/removing viruses and secondly, to estimate quantitatively 
the overall level of reduction of any virus/viral particle, e.g. endogenous retroviral particles.  A case-
by-case approach will be required taking into account the characterisation of the cell line, the use of 
raw materials of biological origin, as well as the nature of the process steps that may be effective in 
inactivating/removing viruses. 
Regardless of the extent of direct virus testing of the production cell line, due to limitations in viral 
detection assays, there remains a potential for unknown contamination of the cells with a virus 
originally present in the cells or arising from materials of biological origin that are used during 
cultivation of the production cells.  Consequently, even when no raw materials of biological origin 
have been used and the cell line is fully tested, the downstream process for all IMPs should be 
evaluated for virus inactivation/removal. 
Validation of virus reduction should be performed prior to the onset of the clinical trial.  Potential 
contaminants may be enveloped or non-enveloped viruses and virus reduction studies should include 
both an enveloped virus and a small non-enveloped virus, preferably a parvovirus.  Especially, it must 
be demonstrated that any virus or viral particle known to be present in the bulk harvest has been 
effectively inactivated or removed during downstream processing.  Case B cells (as defined in Q5A) 
contain endogenous retroviruses or retrovirus-like particles and a retrovirus should be used in 
validating the inactivation/removal of viruses to demonstrate full clearance of particles present in the 
bulk harvest. 
Virus reduction studies should be performed according to the principles of Q5A although a 
demonstration of robustness (i.e. influence of process parameters on virus reduction) may not always 
be warranted as outlined below. The relevant steps in product purification that contribute to virus 
reduction should be described. The capacity of these steps to inactivate/remove potential virus 
 
©EMEA 2008  
 
 
 
          Page 6/9 
 
contaminants should take into consideration the viral safety of the production cell line, e.g. the type 
and level of endogenous retroviral contamination, or the use of human or animal derived materials 
during manufacture and possible levels of contamination.  The CHMP Note for guidance on virus 
validation studies (see references) also provides useful detailed information on such studies. 
It is desirable to investigate the contribution of more than one production step for virus reduction and 
at least two orthogonal steps should be assessed. Orthogonal steps are defined as process steps where 
different mechanisms are responsible for virus inactivation/removal.   The criteria for an effective step 
have been outlined in Note for Guidance on Virus Validation Studies (CPMP/BWP/268/95).  It is not 
necessary to investigate process steps where no significant virus reduction can be expected. 
The reproducibility of an effective virus reduction step should be demonstrated by at least two 
independent experiments. 
In performing the validation study, the limits of (i.e. worst-case) process parameters should be used, 
whenever such conditions are known.  However, during development, such worse case limits may not 
have been defined for a new manufacturing process.  In these cases, use of representative (i.e. set-
point) conditions is justified as long as the manufacturer can demonstrate that the actual 
manufacturing process ran at these set-points. 
Circumstances to support a reduction of the above studies: 
• 
Investigation of a single specific inactivation/removal step might be sufficient whenever 
effective virus reduction of a broad range of viruses, including small non-enveloped viruses 
such as parvoviruses, can be demonstrated for such a step.  However, for case B cells, it will 
usually be necessary to evaluate more than one step in order to demonstrate adequate 
clearance of retroviral particles. 
• 
 Prior experience of the manufacturer with a specific downstream processing step.  In the 
event that a manufacturer is developing similar types of products by established and well-
characterised procedures, virus reduction data derived for these other products might be 
applicable to the new product for an equivalent processing step. 
 
In general, in order to make use of data from such a step, the step should have been carefully 
evaluated, including a thorough study of the process parameters that affect virus reduction.  
If data for more than one product is available for the specific step, the effectiveness of virus 
reduction should be comparable in each case.  Processing prior to the specific step for the 
new and the established product(s) should follow a similar strategy. 
 
A rationale should be provided why prior in-house data can be applied to the new product, 
e.g. referring to viral reduction data of a particular process step would be possible when the 
product intermediate at the stage before such a step has comparable biochemical properties 
and is purified by identical methods.  The manufacturer should provide a critical analysis of 
the manufacturing step for which in-house data will be applied and on the composition of the 
respective product intermediate. This should include, for example, the type of filter, load per 
filter area, flow rates, pressure and composition of product intermediates for virus retention 
filters, or the column dimensions including bed height, load, composition of buffer and 
product intermediates, and linear flow rates for chromatographic methods.  In addition, each 
new product might have components not present in previous products and so the potential 
influence of product-specific components should be considered. The analysis should provide 
complete confidence in the conclusion that in both cases the established manufacturing step 
is similar in its capacity to inactivate/remove potential virus contaminants.  If the comparison 
of the step is not entirely convincing, or if the database is not convincing enough to rule out 
a product-specific effect on virus reduction capacity, at least a single run with an appropriate 
virus is needed to confirm that the step is indeed performing as expected.  If the process 
performance is clearly different, e.g. different chromatographic profiles are obtained using 
the same equipment, then the step should be validated as above and according to the 
principles of Q5A. 
Published data can be useful in indicating the potential of a step to inactivate/remove viruses and can 
provide an insight to the mechanisms involved.  This facilitates an exploration of the key process 
 
©EMEA 2008  
 
 
 
          Page 7/9 
 
parameters that affect virus reduction and in setting worst-case limits for specific steps to be validated.  
Nevertheless, the application of published reduction factors to a specific product would require 
extensive demonstration of comparability of the processes involved, of the product intermediates, and 
an assurance that product specific process factors do not affect virus reduction.  Virus reduction may 
depend on various process parameters and from the specific composition of a product intermediate.  
Furthermore, the assigned reduction capacity may be specific for selected viruses (e.g. 
chromatographic methods).  Therefore, published data have to be carefully assessed. 
Due to the use of dedicated columns and the small number of batches manufactured during early stage 
development, specific column re-use and sanitisation studies are generally not required for IMPs. 
However, whenever columns are extensively re-used for production of IMPs, this should be 
considered in the investigation of the virus reduction capacity. 
Revalidation of virus reduction 
The data generated for IMPs used in a previous trial (e.g. a first phase I trial) may be used for 
subsequent trials.  However, significant changes in manufacture might have been implemented during 
development of an IMP and it has to be considered that such changes may influence directly or 
indirectly (by changes other than in the evaluated process steps) the capacity for virus reduction. 
Therefore re-evaluation before the start of the next clinical trial will be necessary whenever the 
available data do not reflect production of the IMP to be used in the forthcoming clinical trial.  
Depending on the introduced changes, the selection of viruses should be reconsidered and additional 
viruses used if needed, to provide confidence in the virus reduction capacity of the process.  Even if a 
complete validation according to Guideline Q5A is not required in extended clinical trials at late 
stages (e.g. phase III), manufacturers should justify the approach taken considering the selection of 
model viruses and evaluated process steps.  Full viral validation studies according to Q5A should be 
undertaken as soon as the final production and purification process has been established. 
4.2.5 
Description and Qualification of Analytical Procedures 
Different types of analytical procedures can be used to test for viruses in the starting materials and 
intermediate products, or in assessing the virus reduction capacity of the manufacturing process.  
Virus detection assays include broad screen in vitro tests evaluating both cytopathic effect (cpe) and 
hemadsorption in multiple indicator cell lines, in vivo tests and specific viral testing using for example 
PCR.  To test for retroviruses, transmission electron microscopy (TEM), co-cultivation assays using 
different cell lines and assays for RTase such as Product Enhanced Reverse Transcriptase (PERT) may 
be used. 
Irrespective of the clinical trial phase, the suitability of the analytical methods used for viral testing, 
either as a qualitative or a quantitative method, should be substantiated.  Basically, ICH Q5A Chapter 
3.2 “Recommended Viral Detection and Identification Assays” and Chapter 4 “Testing for Viruses in 
Unprocessed Bulk” are applicable.  A sufficiently detailed description of the analytical procedures 
should be provided, including reagents, assay controls, test procedure, and validity criteria, to allow 
for a clear understanding of the assay used and how it is controlled.  Where compendial procedures are 
used, clear references should be given. 
For analytical procedures supporting the qualification of the cell bank system and other starting 
materials as well as testing of unprocessed bulk for viruses, a tabulated summary of the analytical 
qualification/validation results of these procedures should be provided, as appropriate (e.g. results of 
values found for specificity using appropriate positive and negative controls, sensitivity, quantification 
and detection limit).  It is not necessary to provide a full qualification report for each method; however 
such reports should be held available and submitted upon request. 
For analytical procedures supporting the viral reduction studies, full details should be provided which 
show the suitability of these procedures to quantify the (model) virus particles.  These should include 
studies to assess, for example, quantification limit, specificity, intrinsic assay variability, buffer/matrix 
interference with viral infectivity, and product and buffer cytotoxicity that might affect the ability of 
the selected model viruses to infect the indicator cells.  Statistical considerations for assessing virus 
 
©EMEA 2008  
 
 
 
          Page 8/9 
 
assays can be found in ICH Q5A Appendix 3.  Where applicable, a report from a contract laboratory 
which conducted the viral testing may be acceptable. 
4.3 
Virus safety risk assessment 
In addition to the derivation and provision of data on the viral safety of the product, a virus safety risk 
assessment should be provided with an application for clinical trial authorisation.  The factors noted 
under Sections 4.1 and 4.2.1 to 4.2.4 should be taken into account as the primary factors.  In 
accordance with Q5A, testing of the cell line and of all raw materials of human or animal origin for 
viral contaminants, validation of virus reduction and testing of the product at appropriate steps of the 
manufacturing process for absence of contaminating infectious viruses should be considered.  
The risk assessment should include the calculation of estimated particles per dose (see ICH Q5A, 
Appendix 5) and encompass all steps of the production process. 
In particular cases it may be reasonable to consider clinical parameters such as the indication, the 
dose, the frequency of administration, the number of people exposed, the study duration and the 
immunological status of the patients in the overall risk assessment for a clinical trial.  In this context, it 
should be considered that several of these parameters might change between Phases I, II and III.  The 
clinical parameters should not be considered as primary decision parameters, but they can contribute 
to the final decision on whether to authorise a clinical trial from the viral safety point of view. 
Each situation will be considered on a case-by-case basis. 
4.4 
Re-evaluation of viral safety during development 
Process changes are often introduced during development of an IMP and some of them could impact 
on a previously determined viral safety assessment. Whenever changes are introduced in the 
production process of an IMP for which a viral safety risk assessment has been performed, the 
manufacturer should document all changes introduced and for each of them should consider if a re-
assessment of the risk is required.  In some cases it will be clear that the change has no impact on the 
viral safety risk assessment.  However where there is a clear impact or the outcome is uncertain, the 
risk assessment should be re-evaluated and where necessary appropriate practical studies performed.  
All aspects of viral safety assurance should be taken into account in these considerations. 
For changes that might compromise the validity of virus reduction studies, see paragraph 
‘Revalidation’ in Section 4.2.4.2 
4.5 
Format of clinical trial authorisation documentation 
The overall programme of assuring viral safety should be carefully and clearly presented, with explicit 
justification for any deviation from the minimum recommendations made in this guideline. 
The format, as required by the “Detailed guidance for the request for authorisation of a clinical trial on 
a medicinal product for human use to the competent authorities, notification of substantial 
amendments and declaration of the end of the trial” includes a specific attachment, i.e., Attachment 2: 
2.1.A Appendices, 2.1.A.2, Adventitious Agents Safety Evaluation, dedicated to the data on TSE 
agents, virus safety of biotechnological IMPs and other adventitious agents.  All the data should be 
brought together in this Attachment in order to be self-standing and understood in its entirety with 
minimum references to the other sections of the main dossier.  Full reports including raw data of cell 
line testing and viral reduction studies should be available upon request.  During evaluation of the 
submitted data, it may be necessary to request such reports to ensure as clear an understanding as 
possible of the viral safety of an IMP.   Raw data might be provided by contract laboratories or 
internal labs as part of the reports.  When the applicant makes use of prior in-house data (i.e. data from 
other products), an adequate package of data should be provided to allow an assessment of the in-
house data and to provide confidence that these data are valid or supportive for the specific product 
under development.  
For general consideration on virus safety documentation, information to be submitted can take into 
consideration the items stated in volume 2B of the Notice to Applicants, Part II V: virological 
documentation.  
 
©EMEA 2008  
 
 
 
          Page 9/9 
 
REFERENCES (scientific and/or legal) 
Directive 2001/20/EC of the European Parliament and of the Council of 4 April 2001 on the 
approximation of the laws, regulations and administrative provisions of the Member States relating to 
the implementation of good clinical practice in the conduct of clinical trials on medicinal products for 
human use 
ICH Q5A: ICH harmonised tripartite guideline on Viral safety evaluation of biotechnology products 
derived from cell lines of human or animal origin 
CHMP Note for guidance on virus validation studies: the design, contribution and interpretation of 
studies validating the inactivation and removal of viruses (CPMP/BWP/268/95) 
Detailed guidance for the request for authorisation of a clinical trial on a medicinal product for human 
use to the competent authorities, notification of substantial amendments and declaration of the end of 
the trial (ENTR/F2/BL D(2003)). 
Volume 2B of the Notice to Applicants, Part II – IX. concerning chemical, pharmaceutical and 
biological documentation for biological medicinal products, Part II V: virological documentation 
(http://ec.europa.eu/enterprise/pharmaceuticals/eudralex/vol-2/b/pdfs-en/part2_3en.pdf) 
CHMP Note for Guidance on Minimising the Risk of Transmitting Animal Spongiform 
Encephalopathy Agents via Human and Veterinary Medicinal Products (EMEA/410/01 in its current 
version) 
CHMP Note for guidance on the use of bovine serum in the manufacture of human biological 
medicinal products (CPMP/BWP/1793/02). 
Ph. Eur. monograph on “Bovine serum” (01/2008:2262) 
 