30 Churchill Place ● Canary Wharf ● London E14 5EU ● United Kingdom 
An agency of the European Union  
 
 
Telephone +44 (0)20 3660 6000 Facsimile +44 (0)20 3660 5555 
Send a question via our website www.ema.europa.eu/contact 
 
 
© European Medicines Agency, 2016. Reproduction is authorised provided the source is acknowledged. 
 
25 January 2016 
EMA/CHMP/ICH/310133/2008 
Committee for Human Medicinal Products 
ICH guideline E14: the clinical evaluation of QT/QTc 
interval prolongation and proarrhythmic potential for non-
antiarrhythmic drugs (R3) - questions and answers 
Step 5 
 
Transmission to CHMP for adoption  
26 January 2016  
Release for information  
January 2016 
 
 
 
 
 
ICH guideline E14: the clinical evaluation of QT/QTc interval prolongation and 
proarrhythmic potential for non-antiarrhythmic drugs (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 2/20 
 
 
E14 Q&As (R3) Document History 
Code 
History 
Date 
E14 Q&As 
Approval by the ICH Steering Committee under Step 4 
4 June 2008 
E14 Q&As (R1) 
Approval by the ICH Steering Committee under Step 4 
of four newly added Questions on: Sex Differences; 
Incorporating New Technologies; Late Stage 
Monitoring; and Heart Rate Correction. 
5 April 2012 
E14 Q&As (R2) 
Approval by the ICH Steering Committee under Step 4 
of four newly added Questions on: Concentration-
Response Relationships; Combination Products; Large 
Targeted Proteins and Monoclonal Antibodies; and 
Special Cases. 
21 March 2014 
E14 Q&As (R3) 
Approval by the ICH Assembly under Step 4 of the 
revision of the Question #5.1 on: Use of Concentration 
Response Modeling of QTc Data. 
10 December 
2015 
 
 
 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 3/20 
 
 
ICH guideline E14 (R3) - questions and answers 
Table of contents 
20T120T 
20TElectrocardiograms methodology20T ........................................................... 4 
20T220T 
20TGender20T .................................................................................................... 9 
20T320T 
20TPositive control20T ..................................................................................... 10 
20T420T 
20TStudy design20T ......................................................................................... 12 
20T520T 
20TUse of concentration response modeling of QTc data20T ........................... 13 
20T620T 
20TSpecial cases20T ........................................................................................ 16 
20T720T 
20TElectrocardiograms monitoring in late stage clinical trials20T ................... 17 
 
 
 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 4/20 
 
 
1 Electrocardiograms methodology 
# 
Date of 
Approval 
Questions 
Answers 
1.1 
June 
2008 
Please discuss who should read 
electrocardiograms (ECGs), including the 
number and training of readers and the 
need for readers to be blinded. 
The document recommends that the reader should be skilled but does not identify 
specific training that is needed.  A technician reading with cardiologist over-read would 
certainly be consistent with the guidance.  The attempt of the guidance to limit the 
number of readers represented an attempt to increase consistency.  The guidance asks 
for assessment of intra- and inter-reader variability and suggests "a few skilled readers" 
(not necessarily a single reader) to analyse a whole thorough QT study, since many 
readers may increase variability.  Training would be another way to improve consistency. 
It is recommended for the thorough QT Study that core ECG laboratories blind subject, 
time and treatment in order to reduce potential bias.  The T wave analysis, which calls 
for all 12 leads, can be performed after the QT analyses, and requires comparison to the 
baseline ECG; it can, however, be blinded as to treatment. 
1.2 
June 
2008 
What is the position of ICH regarding the 
role of the following reading methods in 
the thorough QT/QTc study and other 
clinical trials? 
 
fully manual 
 
fully automated 
 
manual adjudication (manual over-
read, computer-assisted, semi-
automated) 
The techniques currently in use for the measurement of ECG intervals can be classified 
into three broad categories: fully manual, fully automated, and manual adjudication.  
Within each of these general categories, many different methodologies are subsumed 
that differ in terms of lead selection, the conventions used for defining T wave offset, and 
the criteria for the inclusion and exclusion of U waves.  
ECG readings can be performed on the following waveform presentations: 
 
Raw waveforms: ECG waveforms recorded from a single lead; 
 
Representative waveforms (median beats, reference cycles): Compositional 
waveforms constructed by a computer-based averaging process that involves 
aligning and combining data from all dominant, normally conducted raw ECG 
waveforms from a single lead; 
 
Global Waveforms:  Composite representation of cardiac electrical activity 
constructed by superimposing representative waveforms from all or several 
simultaneously recorded leads to form a spatial-vector complex, by weighted 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 5/20 
 
 
# 
Date of 
Approval 
Questions 
Answers 
averaging of individual representative complexes with low noise and long duration, or 
by other methods. 
Fully Manual 
When using a fully manual reading technique, a human reader is responsible for 
examining the ECG waveform and placing the fiducial points to mark the beginning and 
the end of the intervals, without the assistance of a computer algorithm.  Fully manual 
methods of fiducial point placement can be applied to raw, representative, and global 
waveforms.  When fully manual measurements are made from the raw ECG waveforms 
in a single lead, three or more cycles should be averaged where available to produce the 
final determination of interval duration.  An advantage of this approach is that the reader 
will not be influenced by prior computer placement of the fiducial points, but a weakness 
can be inter- and intra-reader variability, especially when measurements are performed 
over an extended time period (e.g., several months).  Laboratories using manual reading 
techniques should observe standard operating procedures based on prospectively defined 
criteria for determining where the fiducial points should be placed.  All readers in the 
laboratory should be trained in the consistent application of these criteria. 
Fully Automated 
Fully automated reading methods rely entirely upon a computer algorithm for the 
placement of the fiducial points and the measurement of the ECG intervals.  Automated 
ECG interval measurements can be performed on raw, representative, or global ECG 
waveforms.  Most digital electrocardiographs are equipped with algorithms that perform 
measurements on global waveforms.  Although automated methods have the advantage 
of being consistent and reproducible, they can yield misleading results in the presence of 
noise or when dealing with abnormal ECG rhythms, low amplitude P or T waves, or 
overlapping U waves.  The techniques used for construction and measurement of 
representative waveforms and global waveforms vary between different computerized 
algorithms and between different software versions within individual equipment 
manufacturers.  As a result, between-algorithm and within-manufacturer variability of 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 6/20 
 
 
# 
Date of 
Approval 
Questions 
Answers 
fully automated measurements can confound serial comparisons when the equipment or 
algorithm is not constant.   
Manual Adjudication (Manual Over-Read/Computer-Assisted/Semi-Automated) 
The manual adjudication approach refers to reading methods in which a computer 
algorithm is responsible for the initial placement of the fiducial points on the ECG 
waveform.  A human reader subsequently reviews the algorithmic placement of the 
fiducial points, performing adjustments wherever the computerized measurements are 
considered to be inaccurate.  This approach can have the advantage of greater 
consistency and reproducibility than fully manual readings, while providing an 
opportunity to correct any mistakes made by the algorithmic readings.  Laboratories 
using manual adjudication techniques should observe standard operating procedures 
based on prospectively defined criteria for determining when fiducial points should be 
corrected.  All readers in the laboratory should be trained in the consistent application of 
these criteria.  The adjudication procedure should normally be performed on all 
waveforms being used for interval determination.  If an alternative approach is used, 
such as adjudication limited to outlier intervals above and below a reference range, this 
methodology should be validated as described in Question 1.3. 
The ICH E14 Guideline currently recommends either fully manual or manual adjudication 
approaches for clinical trials in which the assessment of ECG safety is an important 
objective, such as the thorough QT/QTc study.  When the thorough QT study is positive, 
fully manual or manual adjudication methods are currently recommended for an 
adequate sample of patients in late phase studies (see Section 2.3 in E14 document).  
When the thorough QT/QTc study is negative, routine ECG safety assessments in late 
phase clinical trials using fully automated reading methods would be adequate.  
1.3 
June 
2008 
The ICH E14 Guideline contains the 
following statement:  “If well-
characterized data validating the use of 
fully automated technologies become 
Efforts to develop more sophisticated and reliable methods for automated ECG readings 
for both QT interval and T wave morphology assessment are encouraged.  There are at 
present no large scale studies to validate the use of fully automated reading methods in 
patients; however, there are examples of thorough QT/QTc studies in healthy volunteers 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 7/20 
 
 
# 
Date of 
Approval 
Questions 
Answers 
available, the recommendations in the 
guidance for the measurement of ECG 
intervals could be modified.”  What 
would be expected of a sponsor that 
wished to validate and apply an 
automated reading method for 
regulatory submissions? 
in which automated methods have been used and validated for QT interval 
measurements against manual methods.  
QT Interval measurement 
There are at present no clear and widely accepted criteria for validation of new semi-
automated or automated methods, but it is expected that each would be validated 
independently for its ability to detect the QT/QTc prolongation effects of drugs that are 
near the threshold of regulatory concern.  Data supporting the validation of a new 
method should be submitted and could include descriptive statistics, Bland-Altman plots 
of agreement, superimposed plots of the baseline- and placebo- adjusted QTc and the RR 
as a function of time, together with data from any trials that have employed the method. 
T wave morphology assessment 
The suitability of automated ECG reading techniques for the assessment of morphological 
abnormalities has not yet been demonstrated.  If a sponsor intends to develop a fully 
automated approach, without visual assessment for morphological changes, validation 
studies should include a demonstration that the automated method is capable of reading 
and interpreting a test set of abnormal ECGs correctly (e.g., abnormalities of T wave 
morphology, overlapping U waves).  As with methods for QT interval determination, 
there are at present no clear and widely accepted criteria for validation of novel 
methods. 
Because changes in morphology can affect interval measurement, fully manual or 
manual adjudication (as defined in Question 1.2) techniques should be performed if 
treatment-emergent changes in morphology are observed.  If, on the other hand, no 
morphology changes are observed, this would support the use of automated 
methodologies, provided they have been validated. 
1.4 
April 
2012 
How does a sponsor incorporate new 
technology or validate new methodology 
into the measurement and/or analysis of 
the QT interval? 
The ICH process is better suited to the determination of regulatory policy once the 
science in a particular area has become more or less clear. In general, it is not well-
suited to the qualification or validation of new technology.  
Sections 2.5.1 and 2.5.2 of the ICH E14 Guideline are rather discouraging about 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 8/20 
 
 
# 
Date of 
Approval 
Questions 
Answers 
methodology outside conventional carts and human-determined measurements.  Since 
ICH E14 was issued, 12-lead continuous recording devices have largely supplanted cart 
recorders in thorough QT studies without a formal validation process because of their 
performance in the context of a positive control.  The impact of other innovative 
technologies can be assessed in studies incorporating a positive control.  While some 
technologies could be assessed using other techniques in the absence of a positive 
control, this is more complex and beyond the scope of this Q&A.   
12-lead continuous recording devices and other new technologies can be used in late 
phase clinical trials.  Even though a positive control is not used in late stage studies, the 
new technology could be validated in other studies (such as the thorough QT study).  In 
cases where a thorough QT study is not done, a sponsor can provide alternative methods 
for validating the technology. 
1.5 
April 
2012 
The ICH E14 Guideline states that QT 
interval corrected by Fridericia’s and 
Bazett’s correction should be submitted 
in all applications; is this still necessary?  
Is there a recommended approach to QT 
correction that is different than that 
specified in ICH E14? 
Changes in heart rate could variably influence a drug’s effect on repolarisation (i.e., QT 
interval) and correction methods with different characteristics are often applied.  The 
principles set below would be applicable in all clinical studies (thorough QT or other 
studies).  
In adults, Bazett’s correction has been clearly shown to be an inferior method of 
correcting for differences in heart rate among and within subjects.  Therefore, QT 
interval data corrected using Bazett’s corrections is no longer warranted in all 
applications unless there is a compelling reason for a comparison to historical Bazett’s 
corrected QT data.  Presentation of data with a Fridericia’s correction is likely to be 
appropriate in most situations but other methods could be more appropriate.  There is no 
single recommended alternative (see Q&A 1.4 on Incorporating New Technologies), but 
the following are some considerations.  
1. Analyses of the same data using different models for correcting QT can generate 
discordant results.  Therefore, it is important that the method(s) of correction, 
criteria for the selection of the method of correction, and rationale for the 
components of the method of correction be specified prior to analysis to limit bias.  
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 9/20 
 
 
# 
Date of 
Approval 
Questions 
Answers 
Model selection ought to be based on objective criteria and consider the uncertainty 
in parameter estimates.  Alternative methods of correction should be used only if the 
primary method fails the pre-specified criteria for selection of the method of 
correction. 
2. Corrections that are individualized to a subject’s unique heart rate QT dynamic are 
not likely to work well when the data are sparse or when the baseline data upon 
which the correction is based do not cover at least the heart rate range observed on 
study drug. 
2 Gender 
#
 
 
Date of 
Approval 
Questions 
Answers 
2.1 
June 
2008 
There are recognized differences in the 
baseline QTc between men and women.  
These were noted in early versions of 
the guidance.  In E14, however, it is 
recommended that outliers be 
categorized as >450, >480 and >500 
ms, regardless of gender.  Can you say 
why there is no gender difference in the 
recommendation? 
The 450, 480, and 500 ms categories refer to the values the E14 document suggests 
sponsors might use in characterizing outliers.  The numbers previously specified for 
males and females referred to “normal” QTc values, which may differ for men and 
women.  This section was not included in the final document, however, and such 
considerations would be largely irrelevant to larger durations (e.g., 480, 500 ms).  As 
the thorough QT/QTc study is designed to examine the propensity of a drug to prolong 
the QTc interval, it is appropriate to perform the study in male or female healthy 
volunteers. 
2.2 
April 
2012 
Should we enroll both sexes in a 
thorough QT study, and does the study 
need to be powered for independent 
conclusions about each sex? 
Post-pubertal males have lower heart-rate corrected QT intervals than do pre-pubertal 
males or females generally.  Women are generally smaller than men, so their exposure 
to a given fixed dose of a drug will generally be higher, and, if a drug prolongs QT, it can 
be expected to prolong it more in women because of the higher exposure.  It is not 
settled whether and how often there are sex differences in response to QT-prolonging 
drugs not explained by exposure alone. 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 10/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
The thorough QT study is primarily intended to act as a clinical pharmacology study in a 
healthy population using a conservative primary objective defining the drug’s effect on 
QT.  It is unlikely that any of a variety of baseline demographic parameters would 
introduce a large difference in QT response to a drug in subpopulations defined by factors 
such as age, co-morbidity, and gender that is not explained by exposure. 
It is encouraged, but not mandatory, to include both men and women in the thorough QT 
study.  Analyses of Concentration-Response Relationship (CRR) by sex can be helpful for 
studying the effect of the drug on QT/QTc interval in cases where there is evidence or 
mechanistic theory for a gender difference.  However, the primary analysis of a thorough 
QT study should be powered and conducted on the pooled population.  If the primary 
analysis is negative and if there is no other evidence suggesting gender differences, 
subgroup analysis by sex is not expected. 
3 Positive control 
#
 
 
Date of 
Approval 
Questions 
Answers 
3.1 
June 
2008 
The ICH E14 Guideline emphasizes the 
importance of assay sensitivity and 
recommends the use of a positive 
control.  In order to accept a negative 
thorough QT/QTc study, assay sensitivity 
should be established in the study by 
use of a positive control with a known 
QT-prolonging effect.  Please clarify how 
to assess the adequacy of the positive 
control in the thorough QT study. 
The positive control in a study is used to test the study’s ability (its “assay sensitivity”) 
to detect the study endpoint of interest, in this case QT prolongation by about 5 ms.  If 
the study is able to detect such QT prolongation by the control, then a finding of no QT 
effect of that size for the test drug will constitute evidence that the test drug does not in 
fact prolong the QT interval by the amount of regulatory concern.  There are two 
conditions required for ensuring such assay sensitivity: 
1. The positive control should show a significant increase in QTc; i.e., the lower bound 
of the one-sided 95% Confidence Interval (CI) must be above 0 ms.  This shows that 
the trial is capable of detecting an increase in QTc, a conclusion that is essential to 
concluding that a negative finding for the test drug is meaningful; 
2. The study should be able to detect an effect of about 5 ms (the QTc threshold of 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 11/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
regulatory concern) if it is present.  Therefore, the size of the effect of the positive 
control is of particular relevance.  With this aim, there are at least two approaches: 
a. To use a positive control showing an effect of greater than 5 ms (i.e., lower 
bound of a one-sided 95% CI >5 ms).  This approach has been proven to be 
useful in many regulatory cases.  However, if the positive control has too large an 
effect, the study’s ability to detect a 5 ms QTc prolongation might be questioned.  
In this situation, the effect of the positive control could be examined at times 
other than the peak effect to determine whether an effect close to the threshold of 
regulatory concern can be detected; 
b. To use a positive control with an effect close to 5 ms (point estimate of the 
maximum mean difference with placebo close to 5 ms, with a one-sided 95% CI 
lower bound >0).  In using positive controls with smaller effects it would be very 
important to have a reasonably precise estimate of the drug’s usual effect. 
Importantly, whatever approach is used, the effect of the positive control (magnitude of 
peak and time course) should be reasonably similar to its usual effect.  Data suggesting 
an underestimation of QTc might question the assay sensitivity, thus jeopardizing the 
interpretability of the thorough QT study results. 
3.2 
June 
2008 
Please clarify the need for blinding the 
positive control in the thorough QT 
study. 
The use of a double-blinded positive control does not appear to be essential, provided 
that the reading of ECGs is performed in a blinded manner as described in Question 1.2 
and the study is carefully designed to ensure that specified study procedures are 
followed uniformly.  This means that the same protocol for administering the test drug 
and placebo, taking blood samples and collecting the ECG data should also be used when 
giving the positive control.  This does not mean that other aspects of the study, such as 
the duration of treatment with the positive control and the other treatment groups, 
would be identical.  If blinding of the positive control is performed, common methods 
include the use of double-dummy techniques and over-encapsulation. 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 12/20 
 
 
4 Study design 
#
 
 
Date of 
Approval 
Questions 
Answers 
4.1 
June 
2008 
In ICH E14, the recommended metric to 
analyse for a cross-over study is the 
largest time-matched mean difference 
between the drug and placebo (baseline-
adjusted) over the collection period. 
Please discuss the most appropriate 
metric to assess a drug’s effect on 
QT/QTc interval when the data are 
collected in a placebo-controlled parallel 
design study (i.e., when there is no 
corresponding placebo value for each 
patient). 
Regardless of the study design, “the largest time-matched mean difference between drug 
and placebo (baseline-adjusted)” is determined as follows: The mean QTc for the drug 
(i.e., averaged across the study population) is compared to the mean QTc for placebo 
(averaged across the study population) at each time point.  The “largest time-matched 
mean difference between drug and placebo” is the largest of these differences at any 
time point. 
The term “baseline-adjusted” in ICH E14 implies that the baseline data are taken into 
account in the statistical analysis. 
Differences in baseline assessment between cross-over and parallel design studies are 
discussed in Question 4.2. 
4.2 
June 
2008 
Please discuss the need for baseline 
measurements, and when needed, how 
they should be collected, for cross-over 
and parallel design thorough QT studies. 
Adjustment for baseline measurements is potentially useful for several purposes, 
including detection of carry-over effects, reducing the influence of inter-subject 
differences and accounting for diurnal effects such as those due to food.  There is no 
single best approach for baseline adjustment, but all planned baseline computations 
should be prospectively defined in the clinical trial protocol.  Two kinds of baseline are 
commonly used: “time-matched” baseline (taken at exactly the same time-points on the 
day prior to the beginning of treatment as on the treatment day) and "pre-dose" baseline 
(taken shortly prior to dosing).  The “pre-dose” baseline is used for adjustment for inter-
subject differences but not for diurnal effects.  The choice of baseline is influenced by 
whether the study is parallel or cross-over. 
For a parallel-group study a time-matched baseline allows the detection of differences in 
diurnal patterns between subjects that would not be detected by a predose baseline.  In 
a parallel study a “time-matched” baseline day, if performed, would ideally occur on the 
day before the start of the study. 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 13/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
In contrast, in a cross-over study a time-matched baseline is usually not necessary 
because adjustments for subject- and study-specific diurnal variation are implicit by 
design in the assessment of time-matched drug-placebo differences in QT/QTc effect.  
The “pre-dose” baseline is therefore usually adequate for cross-over studies.  
Obtaining replicate ECG measurements (for example, the average of the parameters 
from about 3 ECGs) within several minutes of each nominal time point at baseline and at 
subsequent times will increase the precision of the estimated changes in QT/QTc effect. 
5 Use of concentration response modeling of QTc data 
#
 
 
Date of 
Approval 
Questions 
Answers 
5.1 
December 
2015 
The ICH E14 Guideline states (in Section 
3, page 12) that analysis of the 
relationship between drug concentration 
and QT/QTc interval changes is under 
active investigation. Has this 
investigation yielded a reasonable 
approach to concentration-response 
modeling during drug development? How 
can assessment of the concentration-
response relationship guide the 
interpretation of QTc data? 
Concentration-response analysis, in which all available data across all doses are used to 
characterize the potential for a drug to influence QTc, can serve as an alternative to the 
by-time-point analysis or intersection-union test as the primary basis for decisions to 
classify the risk of a drug.  In either case this result is an important component of the 
totality of evidence assessment of the risk of QT prolongation.  The overall assessment of 
risk of QT prolongation includes nonclinical data, the time course of QT prolongation, the 
magnitude of QT prolongation, categorical analyses of outliers, and certain adverse 
events in patients that can signal potential proarrhythmic effects. 
There are many different types of models for the analysis of concentration-response 
data, including descriptive pharmacodynamic (PD) models (e.g., linear or Emax models), 
or empirical models that link pharmacokinetic (PK) models (dose-concentration-
response) with PD models. It is recognized that concentration-response analyses of the 
same data using models with different underlying assumptions can generate discordant 
results. Therefore, it is important that the modeling methods and assumptions, criteria 
for model selection, rationale for model components, and potential for pooling of data 
across studies be specified prior to analysis to limit bias. Prospective specification of 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 14/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
model characteristics (e.g., structural model, objective criteria, goodness of fit) based on 
knowledge of the pharmacology is recommended whenever possible. On occasion, the QT 
effect is not a direct function of plasma concentration.  For example, drugs that cause QT 
prolongation as a result of changes in protein synthesis or trafficking or drugs with 
accumulation into myocardial tissues might demonstrate hysteresis.  Testing for model 
assumptions, hysteresis (a plot of data by-time point and a hysteresis loop plot), and 
goodness of fit should be documented.  
Concentration-response analysis can be challenging when more than one molecular 
entity-multiple drugs or parent plus metabolites-contributes to the QTc effect. 
Important considerations 
Concentration-response data need not come from a dedicated QT study, nor even a 
single study, but there are several new and important considerations. 
1. Data can be acquired from first-in-human studies, multiple-ascending dose studies, 
or other studies. Additional data would be useful to ensure information on exposure 
well above the exposure at the maximum therapeutic dose, to cover the impact of 
accumulation with repeated dosing, drug-drug and drug-food interactions, organ 
dysfunction, or genetically impaired metabolism. It is anticipated that one would 
collect new data to add to previous data, if appropriate, rather than using new data 
for independent analyses. 
2. Efficient concentration-response analysis using data acquired in studies with other 
purposes requires as much quality control as is needed for a dedicated study. This 
includes robust, high-quality Electrocardiogram (ECG) recording and analysis 
sufficient to support a valid assay for ECG intervals (see E14 and Q&A #1). 
3. If there is an intention to pool data from multiple studies, it is important to test for 
heterogeneity.  
4. If there are data characterizing the response at a sufficiently high multiple of the 
clinically relevant exposure (see E14 Section 2.2.2), a separate positive control 
would not be necessary. 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 15/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
Decision-making 
Both the intersection-union test and the concentration-response analysis can estimate 
the maximum effect of a drug treatment on the QTc interval, but they are not used to 
test the same hypothesis.  As mentioned above, inspection of the time course of QT 
prolongation is important.  However, hypothesis testing based on a by-time point 
analysis (intersection-union test or point estimate and confidence intervals) is 
inappropriate in studies designed for a concentration-response analysis, if not powered to 
assess the magnitude of QT prolongation for each time point.      
When using a concentration-response analysis as the primary basis for decisions to 
classify the risk of a drug, the upper bound of the two-sided 90% confidence interval for 
the QTc effect of a drug treatment as estimated by exposure-response analysis should be 
<10 ms at the highest clinically relevant exposure to conclude that an expanded ECG 
safety evaluation during later stages of drug development is not needed. (See E14, 
Section 2.2.4 and Q&A #7).  
Other uses 
In addition to serving as the basis for regulatory decision-making, concentration-
response analysis has established its utility in several settings enumerated below. 
Providing insight into regimens not studied directly  
An understanding of the concentration-response relationship can help predict the QT 
effects of doses, dosing regimens, routes of administration, or formulations that were not 
studied directly. Interpolation within the range of concentrations studied is more reliable 
than extrapolation above the range. 
Predicting QTc effects of intrinsic and extrinsic factors that affect PK  
Understanding the concentration-response relationship can help predict the effects of 
intrinsic (e.g., cytochrome P450 isoenzyme status) or extrinsic (e.g., drug-drug PK 
interactions) factors, possibly affecting inclusion criteria or dosing adjustments in later 
phase studies.   
 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 16/20 
 
 
6 Special cases 
#
 
 
Date of 
Approval 
Questions 
Answers 
6.1 
March 
2014 
The ICH E14 Guideline states that in 
certain cases a conventional thorough 
QT study might not be feasible.  In such 
cases what other methods should be 
used for evaluation of QT/QTc and 
proarrhythmic potential? 
In certain cases the conventional “thorough QT/QTc” study design (a crossover study in 
healthy volunteers with short-term administration of the usual maximum dose and one 
higher dose with placebo and positive control) might need to be modified for a drug or 
active metabolite with a long half-life or delayed QT effect, or because of safety, 
tolerability or practical issues that preclude use in healthy subjects.  In most cases 
alternative designs can be used that may affect power considerations, but do not 
compromise study interpretation.  For example, multiple doses can be studied in a 
parallel design trial or can use patients with the disease for which the drug is intended 
rather than healthy volunteers.   
Where a placebo-controlled comparison using appropriate doses is not possible, 
alternative study designs should incorporate as many of the usual “thorough QT/QTc” 
design features as possible, and the quality and extent of the pre-clinical evaluation (ICH 
S7B Guideline) is particularly critical.  Other useful supplementary data might include 
intensive ECG data acquisition in early phase single or multiple ascending dose studies, 
utilisation of concentration-response analysis, and evaluation of exposures that are 
greater than are anticipated with the intended marketed dose. 
A single dose of a positive control is generally sufficient, even if it precedes the 
investigational drug treatment.  In the absence of a positive control, there is reluctance 
to draw conclusions of lack of an effect; however, if the upper bound of the two-sided 
90% confidence interval around the estimated maximal effect on QTc is less than 10 ms,  
it is unlikely to have an actual mean effect as large as 20 ms. 
When a thorough QTc study of usual or modified design is not feasible, the intensity of 
late phase ECG monitoring will be dependent upon the quality and extent of the non-
clinical and clinical evaluation.  In situations where it is not possible to study higher 
exposures than are anticipated with the intended marketed dose, more intensive ECG 
monitoring might be necessary during Phase 3 trials.  When the non-clinical and early 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 17/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
clinical data do not suggest clinically relevant QTc prolongation, intensive late stage 
monitoring might not be necessary.  Otherwise, monitoring could be conducted as if a 
thorough QT study had been positive to protect patients in later trials and to obtain 
information on the frequency of marked QTc prolongation in the patient population. (See 
Q&As 7.1). 
6.2 
March 
2014 
The ICH E14 Guideline does not address 
the approach to QT measurement during 
drug development in the case of 
combination drug products.  Is it 
recommended that measurement of QT 
prolongation be performed on drug 
combinations? 
In general, combinations of two or more drugs are unlikely to need a thorough QT/QTc 
study or intensive late stage monitoring, if the component drugs have been 
demonstrated to lack relevant effects in thorough QT/QTc studies as described in ICH 
E14.   
If one or more of the component drugs have not been individually characterised for 
effects on the QT/QTc interval, they may be evaluated in combination or independently. 
6.3 
March 
2014 
Are sponsors expected to conduct 
thorough QT studies as part of the 
development of large proteins and 
monoclonal antibodies?   
Large targeted proteins and monoclonal antibodies have a low likelihood of direct ion 
channel interactions and a thorough QT/QTc study is not necessary, unless the potential 
for proarrhythmic risk is suggested by mechanistic considerations or data from clinical or 
non-clinical studies. 
7 Electrocardiograms monitoring in late stage clinical trials 
#
 
 
Date of 
Approval 
Questions 
Answers 
7.1 
April 
2012 
The ICH E14 Guideline describes in 
Section 2.3 (Clinical Trial Evaluation 
After the “Thorough QT/QTc Study”) that 
“adequate ECG assessment to 
accomplish this [monitoring] is not fully 
established.” Is there now a reasonable 
Clarification of Approach to Evaluating QTc in Late Stage Clinical Development 
The purpose of a thorough QT study is to characterize the effect of the drug on 
ventricular repolarization (QT interval).  It is not the purpose of the thorough QT study to 
assess the risk of Torsade de Pointes (TdP) in the target population, but rather to 
determine whether further data are warranted to assess risk.  A finding of QT 
prolongation above the regulatory threshold of interest (a positive thorough QT study) 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 18/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
approach to evaluating QTc in late stage 
clinical development in the case of a 
finding of QT prolongation prior to late 
phase studies? 
might call for further electrocardiographic follow up in late phase studies.  The extent of 
the follow up would be affected by the magnitude of the estimated prolongation at doses 
and concentrations at which this occurs.  If prolongation is substantial at concentrations 
expected to occur in clinical studies, it is important to protect patients in later trials and 
to obtain further information on the frequency of marked QT prolongation.  In some 
cases in which there is a large margin of safety between therapeutic exposures and the 
exposures that result in significant ECG interval changes, an intensive ECG follow-up 
strategy might not be warranted. 
 
The recommended intensity of the monitoring and assessment in late-stage trials will 
depend on: 
1. The magnitude of QTc prolongation seen in the thorough QT study or early clinical 
studies. 
2. The circumstances in which substantial QT prolongation might occur (i.e., in ordinary 
use or only when drug concentrations are markedly increased [e.g., by renal or 
hepatic impairment, concomitant medications]).  
3. Pharmacokinetic properties of the drug (e.g., high inter-individual variability in 
plasma concentrations, metabolites). 
4. Characteristics of the target patient population that would increase the proarrhythmic 
risk (e.g., structural heart disease).  
5. The presence of adverse effects that can increase proarrhythmic risk (e.g., 
hypokalemia, bradycardia, heart block). 
6. Other characteristics of the drug (e.g., pharmacodynamics, safety pharmacology, 
toxicology, drug class, hysteresis). 
The following examples delineate the scope of recommended ECG investigations based 
on outcome of the thorough QT study or early clinical studies.  These could be modified 
by other factors such as A-F above.   
 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 19/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
Examples of ECG Monitoring in Late Stage: 
1. The thorough QT study results in a negative finding as defined by the E14 criteria* at 
the therapeutic dose, but the supratherapeutic dose (relative to Phase 3 dose) shows 
mean QTc effects between 10 and 20 ms.  If there is reasonable assurance that the 
higher dose represents drug exposures that are unlikely to be seen in the patient 
population, only routine ECG monitoring is recommended in late phase trials.  This 
approach provides reassurance for safety because patients are unlikely to experience 
a clinically significant QTc effect.  
2. The thorough QT study results in a positive finding as defined by the E14 criteria* at 
the therapeutic dose, with a mean prolongation <20 ms.  For drugs with this 
magnitude of effect on the QTc interval, intensive monitoring of Phase 3 patients is 
called for.   
Intensive ECG monitoring in clinical trials has two main objectives.  One objective is 
to provide protection to patients who might have large worrisome QT intervals >500 
ms.  A second objective is identifying the frequency of marked QT increases (e.g., 
prolonged QT >500 ms or increases in QTc >60 ms). 
Given the limitations of collecting ECGs in late stage trials, the focus of the analysis 
is on outliers, not on central tendency.  Other than descriptive statistics, detailed 
statistical analysis is not expected.  This monitoring is intended to be performed 
locally, without the involvement of a central core laboratory. 
The timing of ECG collection should be based on the known properties of the drug.  
All patients should receive baseline, steady-state, and periodic ECGs during the trial.  
In addition, ECGs should be collected around Tmax at the first dose and/or around 
steady state in a subgroup of patients or in dedicated studies.  ECG collection at 
around Tmax is not important for drugs with low fluctuations between peak and 
trough concentrations.  If the drug shows a delayed effect in QT prolongation, then 
the timing of ECG collection should reflect this delay. 
3. The thorough QT study results in a negative finding as defined by the E14 criteria* at 
 
 
ICH guideline E14 (R3) - questions and answers  
 
EMA/CHMP/ICH/310133/2008  
Page 20/20 
 
 
#
 
 
Date of 
Approval 
Questions 
Answers 
the therapeutic dose, but the supratherapeutic dose shows a mean effect between 10 
and 20 ms.  If supratherapeutic exposure is anticipated at the clinical dose only in a 
well-characterized subgroup, intensive monitoring as described in Example 2 above 
could be carried out in this subset of the Phase 3 population.  In this case, there 
should be reasonable assurance that the higher exposure is unlikely to be seen in the 
general patient population.  In contrast, if people in the general patient population 
(who can not be readily identified in advance) will in some cases achieve this higher 
exposure, intensive ECG monitoring in the Phase 3 population is expected, as in 
Example 2.   
4. The therapeutic dose results in a mean QTc prolongation of >20 ms.  For drugs with 
large QTc prolongation effects, intensive ECG assessment would be appropriate in all 
patients in Phase 2/3.  Because of the risk of TdP, another important use of ECG 
monitoring in late phase trials would be to assess any risk mitigation strategies (e.g., 
electrolyte monitoring, dose reduction strategies).  Additional ECG assessment over 
and above what is recommended earlier in the Q&A might also be called for (e.g., 24 
hour ECG recording, telemetry, multiple trough ECGs through steady state). 
The sponsor is encouraged to discuss these approaches with the relevant regulatory 
agency(ies) prior to initiation of the Phase 3 program. 
 
*A negative study as defined by the ICH E14 criteria is an upper one-sided 95% CI of 