 
 
 
European Medicines Agency 
 
 
 
7 Westferry Circus, Canary Wharf, London, E14 4HB, UK 
Tel. (44-20) 74 18 84 00   Fax (44-20) 7418 8613 
E-mail: mail@emea.europa.eu      http://www.emea.europa.eu  
©EMEA 2007 Reproduction and/or distribution of this document is authorised for non commercial purposes only provided the EMEA is acknowledged 
 
London, 19 July 2007 
 
Doc. Ref. EMEA/CHMP/BMWP/101695/2006 
 
 
COMMITTEE FOR HUMAN MEDICINAL PRODUCTS (CHMP) 
 
GUIDELINE ON COMPARABILITY OF BIOTECHNOLOGY-DERIVED MEDICINAL 
PRODUCTS AFTER A CHANGE IN THE MANUFACTURING PROCESS 
NON-CLINICAL AND CLINICAL ISSUES 
 
DRAFT AGREED BY BMWP1 
December 2006 
ADOPTION BY CHMP FOR RELEASE FOR CONSULTATION 
 January 2007 
END OF CONSULTATION (DEADLINE FOR COMMENTS) 
April 2007 
AGREED BY BMWP WORKING PARTY  
June 2007 
ADOPTION BY CHMP 
July 2007 
DATE FOR COMING INTO EFFECT 
1 November 2007 
 
This guideline replaces guideline on comparability of medicinal products containing 
biotechnology-derived proteins as active substance (CPMP/3097/02) 
[FL2] 
 
KEYWORDS 
Comparability testing, changes in manufacturing procedure, non-clinical, 
efficacy, pharmacovigilance 
                                                      
 
2 If this supercedes a previous guideline – otherwise delete 
 
 
 
©EMEA 2007 
Page 2/
 
GUIDELINE ON COMPARABILITY OF BIOTECHNOLOGY-DERIVED MEDICINAL 
PRODUCTS AFTER A CHANGE IN THE MANUFACTURING PROCESS 
NON-CLINICAL AND CLINICAL ISSUES 
TABLE OF CONTENTS 
EXECUTIVE SUMMARY................................................................................................................... 3 
1. 
INTRODUCTION......................................................................................................................... 3 
2. 
SCOPE............................................................................................................................................ 3 
3. 
LEGAL BASIS .............................................................................................................................. 4 
4. 
MAIN GUIDELINE TEXT .......................................................................................................... 4 
REFERENCES.................................................................................................................................... 10 
 
 
 
 
©EMEA 2007 
Page 3/
 
EXECUTIVE SUMMARY 
Manufacturers of biotechnological/biological products frequently make changes to manufacturing 
processes of their products both during development and post-approval.  
Demonstration of comparability of the pre- and post change product is a sequential process, beginning 
with quality studies (limited or comprehensive) and supported, as necessary, by non-clinical, clinical 
and/or pharmacovigilance studies.  
This guideline gives advice on the non-clinical and clinical requirements of the comparability exercise 
comparing post-change product to pre-change product where manufacturing process changes are made 
by a single manufacturer, including those made by a contract manufacture. This guideline will address 
the requirements for non-clinical and/or clinical bridging studies to demonstrate that the 
manufacturing change has no impact on safety and efficacy.  
The selection of non-clinical and clinical studies is product-driven, i.e. a strategy for comparability 
testing should be chosen that best predicts or detects clinically relevant differences with sufficient 
accuracy. 
This guideline replaces guideline the guideline on comparability of medicinal products containing 
Biotechnology-derived proteins as active substance (CPMP/3097/02).  
1. 
INTRODUCTION 
Manufacturers of biotechnological/biological products frequently introduce changes in the 
manufacturing process of a given product (both before and after the granting of a marketing 
authorisation). It is assumed that the product’s physico-chemical properties and in vitro / in vivo 
biological activity are well characterised according to state of the art methods. 
For most changes to the manufacturing process, physico-chemical and (quality related) biological 
testing can demonstrate that there is no difference in quality of the product that could adversely impact 
the safety and efficacy of a product. Thus the comparability exercise may be limited to strict process 
validation of the change or be extended to various quality criteria such as in-process controls, 
thorough analytical and biological characterisation of the product and stability data. However, 
sometimes an effect on efficacy and/or safety can be expected on the basis of observed difference(s)or 
cannot be ruled out in spite of the state of the art physico-chemical and biological tests. In such cases, 
additional non-clinical and/or clinical studies will be necessary.  
The type and extent of such studies are variable and will be dependent on numerous factors related to 
the drug substance and the drug product, such as   
• 
knowledge of the molecule and of other molecules of the same class 
• 
the stage of development of products not yet authorised 
• 
the findings in the physico-chemical and biological comparability exercise  
• 
the intended clinical use. 
2. 
SCOPE 
The principles adopted and explained in this document apply to proteins and polypeptides, their 
derivatives, and products of which they are components, e.g., conjugates. These proteins and 
polypeptides are produced by recombinant or non-recombinant cell-culture expression systems and 
can be highly purified and characterised using an appropriate set of analytical procedures, in cases 
when 
 
 
 
©EMEA 2007 
Page 4/
 
• 
Manufacturing process changes are made by a single manufacturer, including those made by a 
contract manufacturer, who can directly compare the processes, analytical in-process data and  
results from the analysis of pre-change and post-change product; and 
• 
Manufacturing process changes are made in development or for which a marketing 
authorisation has been granted. 
The principles outlined in this document might also apply to other product types such as proteins and 
polypeptides isolated from tissues and body fluids. In this case, manufacturers are advised to consult 
relevant guidelines and the competent Regulatory Authority to determine applicability. 
3. 
LEGAL BASIS 
This guideline has to be read in conjunction with the introduction and general principles (4) and part II 
of the Annex I to Directive 2001/83/EC as amended.  
4. 
MAIN GUIDELINE TEXT 
4.1 Need for non-clinical and clinical studies – a risk-based approach 
Demonstration of comparability is a sequential process, beginning with quality studies (limited or 
comprehensive) and supported, as necessary, by non-clinical, clinical and/or pharmacovigilance  
studies.  If a manufacturer can provide evidence of comparability through physico-chemical and 
biological studies, then non-clinical or clinical studies with the post-change product are not warranted. 
In other cases, additional non-clinical and/or clinical data will be required. 
The need, extent and nature of non-clinical and clinical comparability studies will be determined on a 
case-by-case basis in consideration of various factors that may be associated with risk, such as: 
• 
The process complexity, the nature of the change, the potential impact on the molecule 
structure and on the final product profile. 
• 
The nature, and extent of differences demonstrated by the physico-chemical and quality-
related biological characterisation, including product-related substances, impurity profile, 
stability and excipients. Thus, well-characterised differences may provide a background for a 
rational and focused approach with respect to the need for non-clinical and clinical studies.  
• 
Product complexity, including heterogeneity and higher order structure and the availability, 
capabilities and limitations of analytical tests. If the analytical procedures used are not 
sufficient to discern relevant differences that can impact the safety and efficacy of the product, 
additional non-clinical and/or confirmatory clinical testing may be necessary. 
• 
Structure-activity relationship and strength of the association of quality attributes with safety 
and efficacy; 
• 
Relationship between the therapeutic protein and endogenous proteins and the severity of 
(potential) consequences for immunogenicity; e.g. risk of autoimmunity 
• 
Mode(s) of action: unknown or multiple modes of action complicate the evaluation of the 
impact of changes 
• 
Therapeutic indications/target patient groups - The impact of possible differences can vary 
between the target populations covered by the different indications.  
• 
Posology, e.g., dosing regimen and route of administration, for instance, repeated 
administration via the subcutaneous route is more likely to be associated with immunogenicity 
than intravenous administration of a single dose 
• 
The therapeutic window/dose-response curve 
• 
Previous experience, e.g., immunogenicity, safety. Experience with the pre-change product or 
with other products in the same class can be relevant. However, biotechnology-derived 
proteins should be considered individually. 
 
 
 
 
©EMEA 2007 
Page 5/
 
For products in development, all these points above should be taken into consideration. However, 
the extent of the comparability studies will likely increase if manufacturing changes are 
introduced at the later stages of clinical development. A change after conduct of confirmatory 
efficacy and safety studies represents the most challenging situation.  
The selection of non-clinical and clinical studies is product-driven, i.e. a strategy for comparability 
testing should be chosen that best predicts and detects clinically relevant differences with 
sufficient accuracy.  
4.2 Non-clinical data 
If evidence from physico-chemical studies and quality-related biological studies alone is not sufficient 
to establish comparability of the pre- and post-change products, either because these data reveal a 
difference in the two products, or because the nature of the manufacturing change is such that a 
difference cannot be excluded based on the available quality data alone, then data from non-clinical 
studies may provide useful signals of potential therapeutic and safety differences.  
In some cases it may be appropriate to undertake few or even no non-clinical studies, but in other 
situations a more detailed evaluation may be helpful. It is important to note that the design of an 
appropriate non-clinical study program requires a clear understanding of the structure and activity of 
the product. Relevant guidance documents, notably the “Note for guidance on non-clinical safety 
evaluation of biotechnology derived pharmaceuticals” (CPMP/ICH/302/95, March 1998), should be 
taken into consideration. Changes in the impurity profile would not necessarily trigger non-clinical 
studies. However the MAH should justify their strategy in this respect.  
Non-clinical studies should be comparative in nature and should be designed to detect differences in 
response between the pre- and post-change products and not just the response per se. The pre- and 
post-change products should be compared concurrently within the same study. 
Sufficient information and cross-referencing to other sections should be provided in the non-clinical 
section to justify the approach taken in the design of the non-clinical comparability exercise. The 
following approach may be considered and should be tailored to the specific product concerned on a 
case-by-case basis. The approach taken will need to be justified in the non-clinical overview. 
• 
In vitro studies: 
Assays like receptor-binding studies or cell-based assays, many of which may already be available 
from quality-related bioassays, should normally be undertaken with the pre- and post-change products 
being tested concurrently using a comparative study design, in order to assess if any alterations in 
reactivity have occurred and to determine the likely causative factor(s) if comparability cannot be 
established.  
• 
In vivo studies: 
If there are specific uncertainties or concerns regarding pharmacokinetic parameters or 
pharmacodynamic effects relevant to the clinical application, and/or safety, in vivo studies in one or 
more relevant species and properly validated animal model may be considered. Greater reliance would 
be placed on results from studies in a species shown for the pre-change product to be a relevant model 
for man. The final formulation of the post-change product should preferably be used rather than the 
drug substance alone. Ideally, the formulation used in non-clinical comparability studies should be the 
same as that used in clinical trials to facilitate interpretation of data. State of the art methods should be 
employed.  
In general and where the model allows, consideration should be given to monitoring a number of 
endpoints such as: 
� Changes in pharmacodynamic parameters relevant to the clinical application, e.g. duration of 
action. 
 
 
 
©EMEA 2007 
Page 6/
 
� Changes in pharmacokinetic parameters, e.g. clearance. 
� Specifically designed toxicological observations (in-life and post-mortem). The study design 
should be justified, taking into consideration the intended duration of clinical use. 
� The immune response, e.g. antibody titres, neutralising capacity, cross-reactivity. Although the 
predictive value of animal models for immunogenicity in humans is low, (comparative) 
immunogenicity endpoints should be included in repeated dose toxicity studies to aid in the 
interpretation of these studies.  
Ongoing consideration should be given to the use of emerging technologies. For example, in vitro 
techniques such as e.g. ‘real-time’ binding assays may prove useful. In vivo, the developing 
genomic/proteomic microarray sciences may, in the future, present opportunities to detect minor 
changes in biological response to pharmacologically active substances. 
4.3 Clinical studies 
Requirement for a dedicated clinical comparative efficacy and safety study is dependent on the stage 
of development, the type of change being introduced and the impact on quality attributes. Companies 
frequently introduce changes during the development of a given product prior to marketing 
authorisation application. If a manufacturing change is introduced before the confirmatory trial(s), the 
additional data required for the comparability exercise might be fewer than those needed for changes 
introduced after the confirmatory trial(s) or after approval.  
• 
Changes in the manufacturing process before initiation of confirmatory trials 
For this situation, adequate data from physico-chemical and  biological in vivo and in vitro, and 
sometimes also non-clinical or clinical comparability studies such as a single dose pharmacokinetic 
study, are generally sufficient in order to demonstrate that the non-clinical and clinical data obtained 
before the change has been introduced are still valid and can be extrapolated to the post-change 
product.  
• 
Changes in the manufacturing process during  confirmatory trials 
Changes during the confirmatory study are discouraged; if these occurs it is recommended that the 
Applicant seeks scientific advice 
• 
Changes in the manufacturing process after confirmatory trials or after approval 
If a manufacturing change takes place after the confirmatory trial(s) has been performed, or after 
approval, a more thorough comparability exercise is generally required, including physicochemical 
and biological in vitro studies, and may include clinical pharmacokinetic and / or pharmacodynamic 
comparability studies. If this comparability exercise cannot rule out an impact on the efficacy and 
safety profile of the drug, additional clinical study (ies) may have to be performed. Deviations from 
this conceptual level should be justified.  
• 
Further criteria influencing the requirement of comparative clinical data 
Further important issues that should be taken into account when designing and justifying the clinical 
program include results of any non-clinical studies and any clinical experience gained with the pre-
change product and other products in the same category, if relevant, with respect to:  
• 
The relationship between dose/exposure and efficacy/safety 
• 
Whether a dynamic marker has been accepted as a surrogate marker for clinical 
efficacy/safety 
• 
The relationship between dose/exposure and this surrogate marker 
 
 
 
©EMEA 2007 
Page 7/
 
• 
Drug/receptor(s) interaction 
• 
Disease-specific mechanisms of action 
• 
Target organ(s) for activity and toxicity 
• 
Mode of administration 
 
Pharmacokinetic studies  
Pharmacokinetic studies are an essential part of the clinical comparability exercise. Since the aim is to 
demonstrate comparability and not the characterization of clinical pharmacology of the product per se, 
such studies should be comparative. 
A single-dose crossover study is, in principle, acceptable due to usually lower variability than in head-
to-head comparisons. However, factors like immunogenicity and its possible consequences related to 
alterations of pharmacokinetics and/or pharmacodynamics should be considered  
The route of administration should be in accordance with the intended clinical use. If the product can 
is planned to be administered by more than one route (e.g. s.c. and i.v.), it may become necessary to 
test all routes. The selected dose should be in the steep part of the dose-response curve, in order to 
detect relevant differences. The choice of the population (healthy volunteers versus patients) is 
primarily driven by the mode of action of the product. Since PK and PD studies are preferably 
combined, the choice of the study population should be selected based on the PD effects to be shown, 
i.e. whether the PD effects are detectable in a relevant manner in the population of choice. The 
possibility of a carry-over effect should be considered when designing such crossover study. 
The design of comparative PK studies should not necessarily mimic that of the standard “clinical 
comparability” 
design 
(CHMP/EWP/QWP/1401/98), 
since 
similarity 
in 
terms 
of 
absorption/bioavailability is not the only parameter of interest. Differences in elimination 
characteristics between products e.g. clearance and elimination half-life should be explored.  
Pharmacodynamic studies  
Pharmacodynamics should preferably be evaluated as part of the comparative pharmacokinetic study, 
since alterations in pharmacodynamics can sometimes be explained by altered kinetics. Again, studies 
should be comparative in nature and not merely show the pharmacodynamics of the product per se. 
• 
Markers for primary and secondary pharmacodynamics 
As a principle, an endpoint should be selected that fulfils the following requirements: (1) sensitive 
enough to detect small differences, (2) measurable with sufficient precision, (3) clinically relevant for 
the target population. Care should be taken in these cases to investigate a reasonable dose range to 
demonstrate assay sensitivity. Studies at more than one dose level may be useful (see ICH topic E10). 
The choice of marker(s) should be justified and the margin defining equivalence should be pre-
specified and justified. 
In this respect, the choice of the population should be justified. Demonstration of certain primary or 
secondary PD markers might only be apparent in the diseased population as opposed to healthy 
volunteers. For example, immunomodulators aiming at modulating pathologically altered immune 
effector cells would not necessarily exert similar effects in healthy volunteers. 
• 
PD markers as substitutes for efficacy 
Usually in clinical trials, efficacy is defined by one or more clinical endpoint(s). Sometimes PD 
markers are used. A pharmacodynamic marker is a relevant marker for efficacy, if therapy-induced 
changes in that marker to a large extent can explain changes in clinical outcome.  
PD markers are usually more sensitive to changes in activity of the product and can be assessed earlier 
than clinical endpoints and, therefore, they might in some cases represent the most appropriate 
endpoint. However, as the goal of the comparative exercise is showing equivalence of the products, 
usually data are needed concerning the quantitative relationship between the PD marker and the 
clinical endpoint to enable defining and justifying the equivalence margin in terms of efficacy. 
Sometimes it may be useful to use more than one PD marker. 
 
 
 
©EMEA 2007 
Page 8/
 
Research in surrogate endpoints by the applicants / marketing authorisation holders is encouraged, 
since a surrogate marker will be useful in the course of product development.  
Efficacy studies 
• 
Study design 
If no suitable markers exist, or if pharmacodynamic studies fail to establish comparability clearly, a 
comparative equivalence clinical trial using clinical endpoints will be required. Again, studies should 
be comparative in nature, comparing the post-change product with the pre-change product. Equivalent 
therapeutic efficacy should be demonstrated. Usually, clinical studies should be randomised, double 
blind, to avoid bias. Possible differences in efficacy should normally be investigated in studies with 
the highest probability of showing a difference (see ICH topic E10).  
The acceptable equivalence margin should be set taking into account the product release 
specifications, clinical relevance and statistical considerations, and be pre-specified. The sample size 
required should not solely be based on considerations on clinical efficacy, but also on detection of 
differences in safety (see below). 
If an equivalence trial design is not feasible, other designs should be explored and their use discussed 
with the competent authorities. 
• 
Selection of the most relevant patient population/therapeutic indication 
Since therapeutic proteins can be used for different indications and/or different patient populations, 
differential impact on efficacy and/or safety needs to be considered. Usually, a patient population or 
indication should be chosen where differences are best distinguishable, i.e. the most sensitive model 
for efficacy. The choice, however, will also depend on the susceptibility and vulnerability of this 
population to potential safety problems, and will have to be justified by the applicant. The Applicant 
needs to thoroughly discuss and justify if efficacy and safety results of the comparative study in one 
indication or population can reasonably be assumed to be applicable to other populations or 
indications.  
• 
Selection of appropriate endpoints  
As a principle, endpoints should be selected that show differences with the highest accuracy. The 
clinical requirements for comparative studies being part of a comparability exercise can be different 
from those for conventional confirmatory studies. For marketed products, the endpoints might not 
necessarily be those, which had been selected for the confirmatory trials if they are not sufficiently 
suitable for detection of differences. As noted above, pharmacodynamic or other markers like imaging 
techniques can be more suitable than genuine clinical endpoints. The choice of endpoints needs to be 
fully justified. 
• 
Study duration 
The study duration is essentially driven by the choice of the clinical endpoint. The duration should be 
sufficient to detect also minor differences with sufficient accuracy. Available data from literature 
should be included in the justification and discussion of study duration. Since safety data evaluation is 
an essential part of the clinical comparability exercise, the study duration should also be determined 
with the aim of detecting relevant differences of safety findings adequately. 
Clinical safety and pharmacovigilance requirements 
Even if the efficacy is shown to be comparable, the post-change product may exhibit a difference in 
the safety profile (in terms of nature, seriousness, or incidence of adverse reactions). Pre-licensing 
safety data should be obtained in a number of patients sufficient to compare the adverse effect profiles 
of the pre- and post-change product. Care should be given to compare the type, severity and frequency 
of the adverse reactions between the pre- and post-change product.  
Further studies post-licensing may occasionally be needed, e.g. pharmaco-epidemiological studies.  
Applicants should in their discussion of adverse events not only include the incidence, but also 
possible differences in clinical presentation (duration, severity and seriousness, reversibility, response 
to treatment etc.). 
 
 
 
©EMEA 2007 
Page 9/
 
The applicant should give a safety specification in the application dossier for the medicinal product 
under review. This includes a description of possible safety issues related to the changes in the 
manufacturing process. 
• 
Extent of the safety database 
In general, safety data can be gathered as part of the clinical study aiming at establishing equivalent 
efficacy. Study duration and sample size calculation should consider frequency, severity and 
seriousness of expected adverse events as well as the clinical setting of the use of the drug (intended 
for acute / chronic use etc.) (see also ICH guideline ICH E1). Again the general rule applies that the 
aim of such trial is not the detection of adverse events per se, but the evaluation of differences in 
occurrence. 
• 
Safety endpoints 
Specific safety endpoints should be selected, taking into account both the typical safety findings 
known for this product and/or this product class and potential other safety findings, which can be 
deduced from the mechanism of action. Since unexpected safety findings might occur, applicants are 
discouraged from setting up methods in the study protocols solely aiming at the detection of known 
safety issues. The evaluation of comparative immunogenicity should be integral part of safety 
evaluation (see Guideline on Immunogenicity of therapeutic proteins). 
 
Risk Management Plan 
Within the authorisation procedure the applicant should present a risk management plan or after 
licensing of the product an update of the existing one in accordance with current EU legislation and 
pharmacovigilance guidelines. This should take into account risks identified during product 
development and potential risks.  
Any specific safety monitoring imposed to the pre-change product and/or product class should be 
taken into consideration in the risk management plan, in accordance to EU legislation and guidelines 
on the Risk Management Plan (RMP). (current policy to be followed - update the list of guidelines to 
include the mentioned here).  
In the PSURs submitted according current EU legislation, the marketing authorisation holder should 
address reports and any other information on tolerability that might be related to a process change. The 
cycle of submission of the periodic safety update reports (PSURs) might be amended (restarted) on a 
case-by-case basis.  
Timing of the comparability data 
In principle, non-clinical and clinical data, if required, need to be available before implementation of 
the change in the manufacturing process, i.e. marketing the new version of the product. Depending on 
the product and the indication, approval of the process change might be based on pharmacodynamic 
data. Additional clinical/safety data, including immunogenicity data, may be provided after approval. 
 
 
 
©EMEA 2007 
Page 10/1
 
REFERENCES 
• 
ICH topic Q5E, Step 4 Note for Guidance on Biotechnological/Biological Products Subject to 
changes in their Manufacturing Process (CPMP/ICH/5721/03 final approval by CHMP 
December 2004) 
• 
Guideline on comparability of medicinal products containing biotechnology-derived proteins 
as active substance (CPMP/3097/02) 
• 
Guideline on similar biological medicinal products containing biotechnology-derived proteins 
as active substance: non-clinical and clinical issues (EMEA/CHMP/42832/05) 
• 
Guideline on the choice of the non-inferiority margin (EMEA/CPMP/EWP/2158/99) 
• 
ICH topic S6 - Note for guidance on pre-clinical safety evaluation of biotechnology-derived 
pharmaceuticals (CPMP/ICH/302/95) 
• 
Note for guidance on repeated dose toxicity (CPMP/SWP/1042/99) 
• 
Note for guidance on non-clinical local tolerance testing of medicinal products 
(CPMP/SWP/2145/00 
• 
ICH topic E9 Statistical principles for clinical trials – Note for guidance on statistical 
principles for clinical trials (CPMP/ICH/363/96) 
• 
ICH topic E10 Note for guidance on choice of control group in clinical trials 
(CPMP/ICH/364/96) 
• 
Points to consider on switching between superiority and non-inferiority (CPMP/EWP/482/99) 
• 
Note for guidance on clinical investigation of medicinal products in the treatment of diabetes 
mellitus (CPMP/EWP/1080/00) 
• 
Note for guidance on the clinical investigation of recombinant Factor VIII and Factor IX 
products (CPMP/BPWG/1561/99) 
• 
ICH topic E 1 Population exposure: The extent of population exposure to assess clinical safety 
(CPMP/ICH/375/95) 
• 
Note for Guidance on the Investigation of Bioavailability and Bioequivalence 
(CHMP/EWP/QWP/1401/98) 
• 
CHMP Draft Guideline on Immunogenicity Assessment Of Biotechnology-Derived 
Therapeutic Proteins (EMEA/CHMP/BMWP/14327/2006, 24 January 2007) in designing such 
studies. 
• 
Guideline on Risk Management Systems For Medicinal Products For Human Use” 
(EMEA/CHMP/96268/2005) 
• 
Guideline on the Clinical Investigation of the Pharmacokinetics of Therapeutic Proteins 
(CHMP/EWP/89249/2004, 24 January 2007) 
• 
CPMP Note for guidance on the Investigation of Bioavailability and Bioequivalence 
(CHMP/EWP/QWP/1401/98, 26 July 2001) 
• 
DRAFT CHMP Guideline on Immunogenicity Assessment Of Biotechnology-Derived 
Therapeutic Proteins (EMEA/CHMP/BMWP/14327/2006, 24 Jan 2007) 
• 
CHMP Guideline on Risk Management Systems for Medicinal Products for Human Use 
(EMEA/CHMP/96268/2005, 14 Nov 2005). 
Suggest that the "Guideline on comparability of medicinal products containing biotechnology-derived 
proteins as active substance: Quality Issues" (CPMP/BWP/3207/00/Rev 1) be referenced for 
suggestions that may guide the risk assessment of manufacturing process changes. 
