Official address  Domenico Scarlattilaan 6  ●  1083 HS Amsterdam  ●  The Netherlands 
 
 An agency of the European Union      
 
Address for visits and deliveries  Refer to www.ema.europa.eu/how-to-find-us  
Send us a question Go to www.ema.europa.eu/contact  Telephone +31 (0)88 781 6000 
 
 
© European Medicines Agency, 2021. Reproduction is authorised provided the source is acknowledged. 
26 July 2021 
EMA/CHMP/138502/2017 
Committee for Medicinal Products for Human Use (CHMP) 
Reflection paper on statistical methodology for the 
comparative assessment of quality attributes in drug 
development 
 
 
Draft agreed by Biostatistics Working Party 
February 2017 
Adopted by CHMP for release for consultation 
23 March 2017 
Start of public consultation 
01 April 2017 
End of consultation (deadline for comments) 
31 March 2018 
Agreed by Biostatistics Working Party 
June 2021 
Adopted by CHMP 
22 July 2021 
 
Keywords 
Statistical methodology, comparative assessment, quality attributes, 
drug development, manufacturing changes, biosimilars, generics, 
dissolution, inferential statistical methods, similarity assessment 
 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 2/21 
 
Table of contents 
Executive Summary ..................................................................................... 3 
1. Introduction ............................................................................................ 3 
2. Legal basis and relevant guidelines ......................................................... 4 
3. Definitions and working assumptions ...................................................... 5 
4. Approaching the quality attributes comparison task from the inferential 
statistical perspective ................................................................................. 7 
4.1 Understanding a manufacturing process as a data distribution ................................... 7 
4.2 Similarity condition .............................................................................................. 8 
4.3 Using a similarity criterion to investigate if the pre-determined similarity condition holds 
for a single QA ......................................................................................................... 9 
4.3.1 Sampling / Experimental Approach ................................................................... 10 
4.3.2 Revisiting frequently applied similarity criteria .................................................... 11 
4.3.3 Selecting a similarity criterion from a range of possible candidates ........................ 13 
4.4 Overall conclusion of similarity at the quality level ................................................. 14 
5. Implications for settings where the comparison on the quality level is of 
particular relevance in regulatory decision-making ................................... 15 
5.1. Biologicals ....................................................................................................... 15 
5.1.1. General issues relating to Comparability exercises .............................................. 15 
5.1.2. Specific issues relating to manufacturing changes .............................................. 17 
5.1.3. Specific issues for Biosimilar setting ................................................................. 18 
5.2. Small molecules ............................................................................................... 19 
5.2.1 Specific issues for abridged/hybrid applications ................................................... 19 
6. Quality Attributes data comparison protocol ......................................... 20 
 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 3/21 
 
Executive Summary 
This reflection paper identifies specific areas where the quantitative comparative evaluation of drug 
product quality characteristics plays an important role from the regulatory perspective. This might 
involve decision making processes potentially leading to marketing authorisation as well as post-
authorisation decisions during drug lifecycle. The document focusses on methodological aspects in 
relation to statistical data comparison approaches for pre- and post-manufacturing changes, biosimilar 
development, and generics’ development. The reflection paper raises open issues from a statistical 
perspective, and addresses questions related to comparison objectives, sampling strategies, sources of 
variability and options (or limitations) for statistical inference. 
This document is targeted at both experts from industry and regulatory assessors. This reflection paper 
complements other available regulatory guidance where comparative data assessment of quality 
attributes is discussed for certain contexts, but also provides more detailed guidance of how to actually 
carry out the comparison task based on empirical sample data. 
From the methodological perspective, the reflection paper aims to establish a common language and to 
improve understanding among all experts concerned with quality characteristics’ data comparison. It is 
also intended to trigger further discussion of realistic requirements to demonstrate ‘similarity at the 
quality level’ in the different contexts mentioned above. The reflection paper also discusses likely 
limitations hampering statistical inference, pointing towards meaningful, but expectedly less stringent, 
alternatives. 
1.  Introduction 
The comparison of empirical data from quality characteristics of drug products (Quality Attributes, QA) 
is of importance in many areas of drug development. One common objective of such comparative data 
analyses is to demonstrate that two drug products (or drug substances) stemming from two different 
manufacturing processes are similar with regard to relevant QAs. 
Many of these comparisons are carried out during early drug development, prior to the initiation of 
clinical trials. The outcome of such comparative investigations has an impact on decisions concerning 
subsequent development steps. In this early development setting, the adequacy of the (similarity) 
conclusions drawn from comparative analyses of QAs primarily relates to the producer’s risk. Measures 
to control this risk are in the remit of the drug developer, and are hence not in the focus of regulation. 
However, there are also many comparison settings involving comparative QA data analysis with the 
aim to demonstrate similarity, which have a direct (or sometimes even pivotal) impact on regulatory 
decision making. This reflection paper is intended to raise awareness that – in these cases – adequate 
control of the risk for a false positive similarity decision is crucial. From a regulatory decision making 
perspective, it is the regulator’s responsibility to understand the comparison approaches that are 
applied, in order to adequately inform the decisions for approval, variation, and life cycle management 
of medicinal products. 
Examples, where the comparative evaluation of quality characteristics plays a major role in regulatory 
decision making are:  
• 
the comparison of a particular drug product in versions pre- and post-manufacturing change, 
e.g. when it becomes necessary to establish a bridge between clinical trials, where the two 
versions of the drug product were used exclusively,  
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 4/21 
 
• 
the comparison of a candidate biosimilar product to a reference medicinal product at the 
quality level, in particular in development programmes with (suggested) abbreviated 
clinical development parts, 
• 
the comparison of a candidate generic product to the reference medicinal product, e.g. when a 
clinical (bioequivalence) trial is waived, and pivotal evidence to support similarity comes 
from comparative dissolution experiments. 
In situations where pivotal evidence for similarity comes from comparative statistical analyses of 
clinical data, there is an established methodological framework in place, based on drawing inferences 
from samples (patients or healthy subjects). This involves agreed methods to justify equivalence limits 
for the variables of interest and statistical equivalence testing. Within the clinical data analysis 
framework, for each specific similarity criterion the (prospective) estimation of the risks to draw a false 
positive or a false negative decision is common practice. Once those risks are quantified, they serve as 
operating characteristics (OC) for the similarity criterion specified. OCs are usually used to assist in the 
choice of the most suitable statistical criterion (statistical test) to demonstrate similarity. However, in 
situations exemplified above, where decision making primarily relies on comparisons other than clinical 
data (e.g. analyses of QA data or in-vitro experimental data), regulatory decision making is currently 
often driven by heuristic approaches. In general, following such approaches precludes the estimation of 
risks to draw false decisions, i.e. the determination of OCs is precluded as well. This fact currently 
hampers exploitation of the potential of QAs’ data comparisons to serve as a solid basis to draw 
similarity conclusions.  
It has to be acknowledged that the inferential analysis approach applied to clinical data cannot be 
easily transferred to quality data comparison. Distinct differences exist between the two settings in the 
nature of the data-generating processes, as well as in the options to control for important factors 
influencing the data of interest.  
Despite these differences, which will be addressed in more detail in subsequent sections, the goal of 
this paper is to reflect under which circumstances, and to what extent, the implementation of 
inferential statistical methodology can assist or even facilitate comparative evaluation of QA data. 
Following a problem description, a two-step approach is introduced: firstly, consideration needs to be 
given to what would constitute an agreeable ‘similarity condition’ based on assumed underlying data 
distributions; subsequently, a suitable similarity criterion needs to be identified and chosen to assess 
whether the similarity condition truly holds. This choice needs to be informed by exploration of OCs. 
After the definition of the legal basis in Section 2, Section 3 touches upon two related topics of 
comparative QA data analysis, i.e. ‘critically assessment’ and ‘manufacturing process control 
methodology’. Section 4 presents important fundamental methodological prerequisites which need to 
be considered when establishing a statistical framework for decision making based on QAs´ data 
comparisons. Section 5 discusses the options as well as the possible limitations related to the use of 
inferential statistical methods in the context of various analysis settings, which would typically result 
from comparison tasks as exemplified above. Section 6 provides guidance on how the various 
methodological aspects discussed can be reflected in prospective planning, and discusses the 
advantages of the preparation of a ‘QA data comparison protocol’. 
2.  Legal basis and relevant guidelines  
The legal basis and the procedures for making an application for a marketing authorisation are set out 
in Directive 2001/83/EC as amended and in Regulation (EC) No 726/2004. For generic applications the 
legal basis can be found in Article 6 of Regulation (EC) No 726/2004 and Article 10 of Directive 
2001/83/EC as amended. The legal basis for similar biological medicinal products, also known as 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 5/21 
 
biosimilars, can be found in Article 6 of Regulation (EC) No 726/2004 and Article 10(4) of Directive 
2001/83/EC as amended. The Commission Regulation (EC) No 1234/2008, amended by Commission 
Regulation (EU) No 712/2012, outlines the legal basis of the examination of variations to the terms of 
marketing authorisations for medicinal products for human use and veterinary medicinal products. 
Further information and relevant questions & answers on the eligibility and legal requirements of 
applications to the Centralised Procedure for generics and biosimilars are available on the pre-
authorisation page of the Agency's website.  
This reflection paper should be read in conjunction with all other relevant guidelines, especially with 
the current versions of the following: 
• 
ICH guideline Q5E: Note for guidance on biotechnological/biological products subjected to 
changes in their manufacturing process (CPMP/ICH/5721/03) 
• 
ICH guideline Q8(R2): Pharmaceutical Development (EMA/CHMP/ICH/167068/2004) 
• 
ICH guideline Q9: Quality Risk Management (EMA/CHMP/ICH/24235/2006)  
• 
ICH guideline Q10: Pharmaceutical quality system (EMA/CHMP/ICH/214732/2007) 
• 
ICH guideline Q11: development and manufacture of drug substances (chemical entities and 
biotechnological/biological entities) (EMA/CHMP/ICH/425213/2011) 
• 
Guideline on similar biological medicinal products (CHMP/437/04 Rev 1) 
• 
Guideline on the investigation of bioequivalence (CPMP/EWP/QWP/1401/98 Rev. 1/ Corr) 
• 
Guideline on similar biological medicinal products containing biotechnology-derived proteins as 
active substance: quality issues (EMA/CHMP/BWP/247713/2012) 
• 
Guideline on the pharmacokinetic and clinical evaluation of modified-release dosage forms 
(EMA/CHMP/EWP/280/96, Rev1) 
• 
Note for guidance on the clinical requirements for locally applied, locally acting products 
containing known constituents (CPMP/EWP/239/95 final) 
• 
'Variations guidelines' - Guidelines on the details of the various categories of variations, on the 
operation of the procedures laid down in Chapters II, IIa, III and IV of Commission Regulation 
(EC) No 1234/2008 of 24 November 2008 (2013/C 223/01) 
3.  Definitions and working assumptions 
Throughout the text the term ‘drug product’ is used to simplify reading, but it is evident that quality 
comparisons are also made on either the drug substance or on an intermediate level. The 
considerations made in this paper equally apply to all cases where the QA data analysis is of high 
relevance for regulatory decision making. 
In this paper, the term ‘quality attribute’ (QA) is meant to describe any kind of physico-chemical 
characteristic, biological/activity characteristic, immuno-chemical property, purity/impurity 
characteristic, or any other in-vitro characteristic, which is identified a priori as a (sufficiently) 
important attribute to serve as candidate for the comparison task at hand. As regards the scale of 
measurement, the range is from numerically measured QAs (e.g. molecular weight) to qualitatively 
assessed QAs (e.g. colour). The scale of measurement will usually have an impact on the 
methodological options for the actual comparative data analysis to be planned.  
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 6/21 
 
Reflections made in this document are based on the assumption that a set of QAs has been identified a 
priori which is suitable and comprehensive for the intended similarity evaluation. This means that the 
selection process of important QAs – often associated to a ‘criticality assessment’ – is not within the 
scope of this reflection paper. However, it needs to be noted that this selection process in itself has an 
impact on the likelihood to eventually conclude on similarity based on QAs’ data comparison. Hence, 
keeping criticality assessment out of scope of this paper should not lead to an interpretation that its 
importance is neglected. Criticality assessment is discussed in several other guiding documents (see 
also Section 2) from various perspectives and for different compound classes. In the recent past, plans 
for QAs’ data comparison have been proposed which categorise QAs according to their criticality (e.g. 
into different 'tiers'), foreseeing different comparative analysis techniques (i.e. similarity criteria) with 
graded rigour for the categories defined. Of note, such proposals would implicitly suggest that it would 
indeed be possible to rank different inferential statistical comparison approaches according to their 
potential to correctly decide upon (dis)similarity. This directly relates to the exploration of OCs, and 
underlines the importance of the framework introduced in Section 4 of this document. 
Performing a comparison at the quality level based on samples taken from two manufacturing 
processes can have the interpretation that there is interest in drawing conclusions on similarity 
between the entirety of the material produced by each of the two manufacturing processes. When 
addressing the ‘entirety of material produced’ by a certain manufacturing process, the question arises 
in how far the process is capable of producing material of ‘consistent’ quality over a certain time span. 
Whilst process-control methodology as well as release testing are usually foreseen to guarantee 
targeted quality standards within one specific manufacturing process, an assumption of ‘consistent 
manufacturing’ can be an oversimplification in some cases. For example, there might be shifts or drifts 
in some QAs within the control limits, which might not be irrelevant from the (process) comparison 
perspective. However, it is important to note that the interpretation of inferential statistical analysis 
would require some sort of assumption concerning the consistency within the entirety of the material 
produced, from which samples are drawn and taken for data analysis. This aspect is expected to 
complicate the implementation of inferential statistical methodology to support a similarity conclusion 
based on QAs’ data comparison. On the other hand, process control and release testing might also be 
seen as sources of important information potentially contributing to the comparison task at the quality 
level. 
In order to be able to reflect upon the potential of inferential statistical methodology in the context of 
QAs’ data comparison, a simplistic view is followed in the remainder of the reflection paper: whenever 
it is mentioned that two products are compared, it is assumed that these products can be 'consistently' 
manufactured, guaranteed by adequate process-control measures. It needs to be kept in mind that the 
assumption of 'consistency' can be a very strong assumption, which will be hard to verify in many 
practical situations, in particular with regard to newly established manufacturing processes. It is also 
important to note that the ‘consistency’ assumption (i) is generally not in contradiction with a certain 
within-process variability of QA data, and (ii) should not be seen to conflict with the general goal to 
strive for ‘Continual Improvement of Process Performance and Product Quality’ as described in ICH 
Q10 (Pharmaceutical quality system, EMA/CHMP/ICH/214732/2007). However, changes introduced to 
improve product quality would be expected to alter some QAs (on purpose), and for the time periods 
where such changes are introduced, the ‘consistency’-assumption might thus not be fulfilled, for 
reasons well understood. 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 7/21 
 
4.  Approaching the quality attributes comparison task from 
the inferential statistical perspective 
Generally, inferential statistics aims at making conclusions about an ‘underlying truth’ that cannot be 
completely observed (e.g. the entirety of material produced by a manufacturing process) based on 
samples (e.g. batches). In contrast, descriptive statistics focuses on describing the observed samples 
only. Therefore, whether an approach is inferential or descriptive does not primarily depend on the 
specific method or criterion that is applied, but on the conclusions that are intended to be drawn – i.e., 
as soon as a conclusion is made that goes beyond the samples at hand, the approach is inferential by 
definition. In particular, as similarity exercises aim at making conclusions about similarity of products 
resulting from manufacturing processes in general, and not only about the batches at hand, a similarity 
exercise is generally considered to be an inferential approach, independent from the applied method. 
From the methodological perspective, two main aspects need to be addressed (in sequential order) to 
enable statistical inference from QA sample data:  
(a) Thinking about underlying data distributions, what constitutes an agreeable ‘similarity 
condition’? (details in sections 4.1. and 4.2.) 
(b) What is an adequate ‘similarity criterion’ to assess whether the similarity condition can be 
assumed to hold? (details in section 4.3.) 
With the subsequent sections a framework for comparative statistical inference is introduced based on 
answers to questions posed under (a) and (b) above. 
4.1 Understanding a manufacturing process as a data distribution 
Performing a comparison at the quality level based on samples taken from two manufacturing 
processes can have the interpretation that there is interest in drawing conclusions on similarity 
between the entirety of the material (which will ever be) produced by each of the two manufacturing 
processes. A fundamental methodological aspect is that a manufacturing process can be viewed as a 
data generating process. QAs can be measured on an ongoing basis, e.g. from batch to batch. As a 
certain variability for the quality of the resulting manufacturing output is usually assumed, the 
collected data from individual units of observation (e.g. batches) cannot be expected to be all exactly 
the same for one specific QA all the time. The actually measured QA values over time vary to some 
extent, resulting in an empirical data distribution for each measured QA. In order to “formalise” the 
underlying data generation process, one usually searches for options to approximate the empirical 
(actually seen) distribution with a theoretical distribution, which corresponds to a mathematical 
function. Commonly, those functions contain one or more distinctive parameters describing the shape 
of the distribution that underlies the “best” approximation to the data. As an example, the normal 
distribution with its two parameters to determine the mean and the variance is often used as an 
approximate distribution. This has a strong mathematical justification, as variability that results from 
many small disturbances can be proven to behave closely to such a normal distribution. However, 
many other theoretical functions can serve to approximate empirical distributions. 
A consequence of this ‘model thinking’ via a mathematical distribution function is that it is not the 
actual sample (e.g. the last three batches produced) itself that is of utmost relevance for decision 
making on similarity, but the underlying data distribution from which the actual material is ‘sampled’. 
Hence, produced (and sampled) material needs to be understood as ‘vehicle’ to estimate some 
characteristics of the underlying distribution. In this context, it is important to understand that any 
similarity/equivalence claim eventually made after a comparative data analysis always refers to two 
underlying data distributions, and not to the two sets of samples taken from two processes (e.g. two 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 8/21 
 
sets of batches). Such understanding corresponds to the general idea of statistical inference. In 
contrast, in order to describe the samples drawn, descriptive statistical methods are used. 
The intention to approximate the empirical data distribution for a QA by making use of a specific 
statistical distribution function requires the simplifying assumption of a consistent manufacturing 
quality for that QA over time (see also Section 3). As manufacturing changes can alter a QA’s empirical 
data distribution, the underlying assumptions of the data generating process (the model distribution) 
would also be required to change. If empirical QA data for one drug product (manufacturing) would 
stem from two (or even more) different distributions over a certain production period, this would 
usually hamper a straightforward inferential statistical data comparison. In the past, examples were 
discussed where shifts or drifts in some QAs occurred within control limits which were considered 
potentially relevant from the (process) comparison perspective. This difficulty with the consistency 
assumption can complicate the implementation of inferential statistical methodology to support a 
similarity conclusion based on QAs’ data comparison. On the other hand, it should be clear that 
problems with potential inconsistency cannot be simply overcome by declaring a similarity exercise to 
be ‘descriptive’ only, as the intended conclusions are still inferential in nature.  
4.2 Similarity condition 
Although several criteria to support similarity claims with regard to a QA have been proposed in 
practice, the underlying question about what actually constitutes the ‘similarity’ that is intended to be 
concluded has rarely been addressed in an explicit and quantitative way. Following the understanding 
that any similarity/equivalence claim eventually made after a comparative data analysis always refers 
to the two data generating distributions underlying the manufacturing processes, such a claim requires 
in first place an agreement on a ‘similarity condition’, i.e. a concise description for when two data 
distributions allow a conclusion of ‘similarity’. It is important to differentiate the ‘similarity condition’ 
from the ‘similarity criterion’: The former corresponds to a consensus between stakeholders involved in 
regulatory decision making (applicants as well as regulatory agencies’ experts). The latter is a concrete 
instruction for how empirical data should be analysed to check whether the a priori agreed similarity 
condition can be assumed to hold or not. 
To specify the similarity condition, considerations related to the maximum allowed difference between 
the two underlying data distributions for the specific QA are of interest. The question needs to be 
answered as to which differences would still be compliant with a statement that the material from the 
two processes can be considered sufficiently similar. Ideally, this should be guided by an 
understanding of what differences in a QA could have an impact on clinical efficacy or safety. In 
practice, however, such knowledge is usually very limited. 
Another important aspect is the question of whether any deviations between two underlying 
distributions in a certain QA would be equally relevant in both directions, i.e. the question could arise 
of whether it would be sufficient to rule out marked differences in one direction only (e.g. rule out 
increase in impurity, or decrease in potency), or if the goal is to protect against differences in either 
direction. This question is not only related to the nature of the QA itself, but also to the regulatory 
context of the comparison task (i.e. it might be different in the pre/post-manufacturing change setting 
as compared to the biosimilarity setting, see Section 5).  
For a particular QA, the type of underlying distribution will also depend on the scale of measurement. 
The spectrum of the scales of measurement ranges from nominal (e.g. colour of a liquid substance) to 
continuous (e.g. measured binding capacity).  
In the following, the principle of the ‘similarity condition’ is exemplified assuming interest lies in a QA 
with an underlying continuous measurement scale. In the example below, the blue model function 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 9/21 
 
approximates the QAs’ data distribution for the reference product (R), and the green function depicts 
the model distribution for the test product (T).  
 
             Figure 1                                       Figure 2                                       Figure 3  
Distributions can be different regarding location (Figure 1), spread (Figure 2) or combinations thereof 
(Figure 3). As ‘similarity’ is context-dependent, no universally applicable/agreeable similarity condition 
exists. However, for the comparability task for a specific QA, consensus regarding the ‘similarity 
condition’ is required. As distributions may be characterized by parameters, similarity of two 
distributions could be defined via similarity of parameter(s) – such as the mean – which determines 
the centre of a distribution. If similarity in means was the only requirement to conclude on similarity in 
general, an agreeable similarity condition in such a case could be described via Figure 2. Alternatively, 
following the idea that the entirety of the material produced by the reference manufacturing process 
(within given limits) represents acceptable quality, similarity could be defined based on the overlap of 
the test distribution with a reference range defined based on the underlying distribution for the 
reference product. Following this understanding of similarity, the distributions in Figure 3 would 
support a similarity conclusion, in contrast to the ones in Figure 1 and 2. These possibilities are only 
two intuitive examples to define the similarity condition. Many other possibilities exist. Furthermore, it 
is important to mention that one and the same similarity condition might not be equally meaningful for 
the whole range of QAs within one specific comparison task. Of note, the principle exemplified above 
can also be applied to other scales of measurement, although other statistical methods may be needed 
for evaluation. 
In conclusion, it needs to be noted that for most comparisons of QAs there is no general agreement yet 
regarding what constitutes an agreeable similarity condition based on the underlying distributions. 
However, as long as this question remains open, any subsequent discussions regarding the adequacy 
of a certain similarity criterion (see Section 4.3) aiming to support a similarity claim based on samples 
falls short. In particular, operating characteristics of a similarity criterion such as the probability of 
correctly/falsely concluding similarity cannot be quantified when there is a lack of consensus and pre-
specification of the similarity condition. Hence, the selection of the applied ‘similarity criterion’ (see 
Section 4.3) needs to be preceded by the definition of the ‘similarity condition’ at all times. 
4.3 Using a similarity criterion to investigate if the pre-determined 
similarity condition holds for a single QA  
Several different similarity criteria have been applied in the past to support similarity claims. In many 
instances however, when the suitability of those criteria was discussed in the context of regulatory 
decision making, a preceding discussion to reach a common understanding of what constitutes the 
condition of similarity was lacking. However, as mentioned above, a clear idea regarding the similarity 
condition for a specific QA in a given context is essential before a similarity criterion is applied based 
on observed (sample) data. 
No similarity criterion can be generally considered ‘right’ or ‘wrong’, because no criterion will lead to a 
correct decision in all situations. In particular, as the underlying truth is not observable, it will never be 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 10/21 
 
known whether a specific decision on the fulfilment of a similarity condition based on a similarity 
criterion is right or wrong. Nevertheless, the operating characteristics of similarity criteria regarding 
their capability to correctly decide on a pre-determined similarity condition can be characterized under 
certain assumptions. The next sections introduce and discuss those assumptions. 
4.3.1 Sampling / Experimental Approach 
The application of inferential statistical methods and the interpretation of their results require that 
samples of units taken for analysis are representative of the underlying data generating process(es). 
One selection strategy to realise the goal of representativeness would be random sampling. However, a 
random sampling approach might not be possible in practice, nor optimal given the nature of the 
manufacturing processes. A typical situation is the availability of a (limited) number of production 
batches, often produced consecutively. In such a scenario, the question about ‘representativeness’ of 
available batch material is clearly dependent on (i) the fulfilment of the assumption of a 'well-
controlled consistency' in the manufacturing process(es) per se, and (ii) the available knowledge 
concerning sources of variability.  
For an actual sampling plan, this knowledge needs to be taken into account to define the ‘unit of 
observation’, to also avoid repeated sampling of units carrying no further relevant information for the 
comparative analysis. One commonly used approach is to see the production batch as the unit of 
observation, which can be used for data analysis (one data point per batch). Nonetheless, it is 
important to strive for a thorough understanding of the sources which can cause variability in the 
actually measured values of the QAs of interest. One meaningful way to categorise sources of 
variability is to identify the level on which a certain factor will cause variation in the measured QAs. It 
is important to note that the actual spectrum of variability-generating factors can substantially differ 
between small/synthesised and biological molecules. With synthesised products, manufacturing in itself 
may be less prone to introduce much variability in comparison to production of biological products. 
Variability seen in QAs of small molecules is more likely to be attributable to variations in assays and 
measurement systems. 
Overall, one/some of the following sources of variability may turn out to be relevant (non-exhaustive 
list): 
• 
sources causing between-batch variability, e.g.  
o 
location of manufacturing (batch source), 
o 
scale of manufacture, 
o 
age of the batch (time since manufacturing), 
o 
source of starting materials;  
• 
sources causing within-batch variability, e.g. 
o 
circadian effects, 
o 
time since batch-manufacturing start; 
• 
sources causing within-sample variability, e.g. 
o 
use of different assays to measure one and the same QA, 
o 
ill-defined or variable sample preparation/storage; 
• 
sources causing within-assay variability: e.g.  
o 
measurement error related to assay accuracy and assay precision. 
It is generally not possible to identify all factors which cause variability in measurements. However, 
sufficient understanding of the potential primary sources of variability in the data is key to decide upon 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 11/21 
 
what is actually taken as the unit of observation. The definition of the unit of observation is a 
necessary pre-requisite for sampling considerations. 
 
 
There might be situations where the comparison task at the quality level can be approached following a 
prospective (experimental) strategy, allowing for a priori considerations regarding adequate sampling. 
This may include strategies for stratified sampling, representing the deliberate choice of certain sample 
units based on the assumption that these are representative for the underlying data generating 
process. 
4.3.2 Revisiting frequently applied similarity criteria  
Similarity criteria based on statistical intervals 
Similarity criteria are often based on statistical intervals. Most frequently applied similarity criteria 
require that all test samples (or at least a given percentage) are included in an interval (‘reference 
range’) that is estimated based on the reference samples. A less frequent approach is a requirement 
that a statistical interval estimated based on test samples should be included in the reference range. 
The general idea behind this approach is to show that the manufacturing process for the test product 
will result in a product that lies within the ‘range of variability’ of the reference product, as the 
reference samples represent acceptable quality (‘clinically qualified’, see Figure 3 in Section 4.2).  
The operating characteristics of such criteria in terms of false positive and false negative regulatory 
decision making will strongly depend on the number of test samples. Generally, the probability of 
fulfilling such a criterion increases with decreasing number of test batches. This means that a 
sufficiently large number of test batches will be required to limit the probability for a false positive 
conclusion. The probability for a false negative conclusion, on the other hand, will increase with an 
increasing number of test samples. This antagonism is usually explored in the investigation of 
operating characteristics of interval-based criteria. Operating characteristics will also depend on how 
well the reference range captures the true ‘range of variability’ of the underlying reference distribution, 
which will usually also depend on the number of reference samples.  
Examples of interval-based similarity criteria, which feature the properties mentioned above, are the 
‘min-max’-approach, the ‘+/- x-sigma’ approach as well as the ‘Tolerance Interval’ approach. 
Min-Max, X-sigma and Tolerance Intervals 
In many instances of QA data comparison, the interval determined by the range between the minimum 
and the maximum data point observed for the reference distribution is used as ‘reference range’. 
Alternatively, x-sigma intervals (i.e. mean +/- x*SD, SD being the standard deviation) are also 
frequently proposed as reference range. This is often justified by mean +/- x*SD covering a given 
percentage of the reference distribution (under a normal distribution assumption), e.g. mean+/-3*SD 
covering 99% of the reference distribution. However, it is important to distinguish between the ‘true’ 
mean+/-x*SD range of the underlying distribution and the range estimated based on the sample mean 
and sample standard deviation. With the latter range it is generally not possible to accurately 
determine the true range of variability (e.g. the ‘99%-claim’ as mentioned above) due to measurement 
error and other sources of variability.  
As an alternative to x-sigma intervals, tolerance intervals (TI) that take sampling variability into 
account are sometimes proposed as reference range. A TI is usually derived to estimate a data range 
by which a specified proportion p (e.g. the central 99%) of the underlying distribution is assumed to be 
covered with a pre-specified degree of confidence (e.g. 95%). However, although TIs cover the central 
proportion of the distribution (e.g. the true mean +/- 3*SD range) with high certainty, this does not 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 12/21 
 
imply that the TI is a good (narrow) estimator of this range. In contrary, as TIs take measurement 
error into account for quantification of uncertainty regarding the estimate of the central proportion of 
the reference distribution, this does imply that TIs are generally broader when the uncertainty is large 
(i.e. sample size is small). 
Of note, these observations do not automatically disqualify the intervals mentioned for a QA data 
comparison task. From a pure conceptual perspective, defining a target range with such intervals 
appears intuitive. However, from the regulatory perspective, the concern for an unreasonably high risk 
for false positive conclusions on similarity would need to be addressed. Applicants should therefore 
discuss the operating characteristics of these approaches in regulatory submissions and justify that the 
risk of a false positive conclusion is acceptably low. 
Prediction Intervals 
Prediction intervals (PI) are estimated to describe a data range covering data outcome of future units 
with a pre-specified degree of certainty (% PI). PIs can be derived for one single future observation, 
for a set of k future observations, but also for a parameter characterising the underlying distribution of 
future observations, e.g. for the mean of future observations. In the context of comparative QA data 
analysis, it appears intuitive from a conceptual perspective to use PIs to characterise data distribution 
for the test-product (or post-manufacturing-change condition), as any similarity claims would be made 
in relation to future manufacturing. As for all other intervals mentioned so far, the context of use of a 
PI in the definition of a similarity criterion will strongly influence the operating characteristics, and 
hence the acceptability of prediction intervals. 
Bayesian Credible Intervals 
Computation of intervals following Bayesian principles have a fundamentally different interpretation 
compared to the intervals described above which follow a frequentist statistical approach. Bayesian 
intervals generally consider unknown distribution parameters (or other quantities of interest) as 
random. Credible intervals hence can be interpreted as region on a particular data scale, which 
contains the parameter of interest with a specified probability. The acceptability of Bayesian 
approaches to inform regulatory decision making remains controversial. In the context of QA data 
comparison, the application of Bayesian methodology, e.g. to characterise and (continuously) update 
distribution models of a certain manufacturing process, could be considered a reasonable strategy. 
However, acceptability of Bayesian approaches implemented in QA data similarity criteria would not 
only require persuasive operating characteristics, but also an acceptance of the conceptually different 
interpretation of data analysis in general. 
Similarity assessment based on Equivalence testing 
Equivalence testing aims to demonstrate that a difference/distance between parameters describing an 
underlying distribution (e.g. mean) larger than a given margin can be reasonably excluded. Hence, an 
important question to be addressed upfront is the choice of a suitable characteristic(s) to be compared. 
In addition, a metric to describe the difference/distance between the parameters for the two 
distributions needs to be defined. The definition of such a metric relates to the intention to derive one 
single measure to describe the difference of interest, and thereby to 'simplify' the analysis task. For 
the example of the comparative analysis of means, this metric could simply be the difference of means 
or the ratio of means. Equivalence is usually concluded if a confidence interval computed in terms of 
the given metric for the parameter of choice (e.g. the difference in means) is entirely contained within 
a pre-specified acceptance range. Thereby, the acceptance range constitutes the (agreed) similarity 
condition, i.e. two distributions are considered similar if the difference in the parameters of interest for 
the underlying distributions is smaller than the maximal difference allowed according to the specified 
acceptance range. The advantage of equivalence testing is that operating characteristics, in particular 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 13/21 
 
the probability for a false positive similarity claim, are well understood under certain assumptions. 
However, equivalence testing is often criticized for the underlying ‘similarity condition’ not being 
compliant with the usual understanding of similarity, which does not require that distribution 
parameters are similar. In addition, the basis for justifying an acceptance range is often lacking, as the 
quantitative relationship between a QA and clinical outcomes is usually poorly understood. 
The methodological approach of equivalence testing of means exemplifies a setting, where intervals 
get utilised for two clearly distinct purposes in the comparative data analysis: One purpose is the 
‘quantification of uncertainty of estimation’. This is done by computation of the confidence interval for 
the difference in means. The other purpose is the ‘definition of an acceptance range’. However, in 
many comparative analyses other than equivalence testing of means, it turns out to be difficult to keep 
those two mentioned purposes separate. For example, in the case of computing a TI from reference 
data, the resulting interval is usually supposed to serve both goals: quantification of uncertainty and – 
at the same time – definition of an acceptance range. The fact that those two methodological aspects 
often mixed makes a general judgement of the suitability of certain statistical intervals for the QA data 
comparison task difficult.  
4.3.3 Selecting a similarity criterion from a range of possible candidates 
Any similarity criterion based on statistical analysis of QAs’ data, which is supposed (or can be 
expected) to have a substantial impact on regulatory decision making, needs to be assessed for its 
capability to lead to the right decisions. From the methodological point of view, an a priori investigation 
is required to assess the chances for incorrect decisions associated with the application of a certain 
similarity criterion. Most of the time the actual outcome of a comparative QA data analysis will lead to 
a ‘yes’ (similar) or ‘no’ (not similar) outcome. Therefore, an understanding of the probability for a false 
positive decision on similarity (erroneously deciding for similarity of underlying distributions that are 
not compliant with the pre-specified similarity condition) is central. The same applies for the probability 
for a false negative decision (erroneously deciding against similarity of underlying distributions that are 
compliant with the similarity condition). These probabilities generally behave antagonistically, and their 
magnitudes depend on various factors such as the true underlying distributions, the pre-specified 
similarity condition and sample size. With a systematic theoretical investigation of how the probability 
for a similarity decision depends on those factors, the ‘operating characteristics’ of a suggested 
similarity criterion can be explored. 
A framework could be established for such a systematic investigation of the operating characteristics of 
candidate similarity criteria. As the true underlying test and reference distributions are unknown, the 
probability of a similarity conclusion for a given similarity criterion should be investigated for a range of 
scenarios with different underlying distributions (for example two normal distributions varying the 
difference in means, and ratios of standard deviations). Influence of sample size (number of test and 
reference samples/batches) on operating characteristics should be investigated within the framework. 
The relevance of the chosen framework should be justified, particularly the plausibility of the 
underlying test and reference distributions and the feasibility of sample sizes. 
Such exploration could generally include several candidate similarity criteria to eventually select the 
optimal criterion, given the expected/feasible setting for sampling and data collection. Similarity 
criteria may also be ‘calibrated’ to have the desired operating characteristics. 
As a matter of principle, investments in generating more evidence should be rewarded. In other words, 
the quality of decision making should generally increase with increasing amount of information, e.g. 
with increasing number of batches. Vice versa, comparison approaches which would make it easier to 
pass a defined similarity criterion by decreasing the amount of information on which the decision is 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 14/21 
 
based cannot be endorsed. Large uncertainties in the estimation of reference data (distributions) 
should never manifest in large acceptance ranges. 
The computation of some intervals (introduced above) requires further parameterisation, e.g. central 
proportion coverage with TIs, etc. Such parameterisation should be done and justified at the planning 
stage, before actual QA sample-data is seen. Criteria with a low potential for misleading outcome 
interpretation associated with the arbitrary choice of actual values for such parameters would generally 
be preferred. The variety of comparison approaches may also comprise analyses requiring less (or no) 
specific a priori distributional assumptions, such as non-parametric techniques, bootstrapping or other 
re-sampling methods ('distribution free’ intervals). Furthermore, it is important to note that different 
concepts for statistical intervals not only differ in their method of computation, but also (and 
importantly), in the interpretation of the resulting interval. 
From the regulatory perspective, the main concern remains the false positive similarity conclusion. 
Therefore, characterisation of this risk is considered most important and the selection of a similarity 
criterion needs (also) be driven by minimisation of that risk. Any justification of an acceptable maximal 
magnitude of this risk for one single QA’s data comparison needs to be put in context of the overall risk 
for a false conclusion on similarity based on the analyses of all QAs’ comparisons. See next sub-section 
for further details. 
4.4 Overall conclusion of similarity at the quality level 
The considerations outlined in the previous sections describe an outline for inferential evaluation of 
similarity for a single QA. For many tasks of comparing data on the product-quality level, it is expected 
that the comparison will involve more than one QA. This would generally mean that all the 
methodological considerations explained above would need to be applied separately for each QA 
selected for the comparison task. The read-outs for different QAs are expected to be observed on 
different scales with varying quality of information, ranging from binary outcome to continuous 
measurements. Even if the assay read-outs for a set of QAs are all on a metric/continuous scale, the 
shapes of underlying data distributions can be rather different. In this context, it is generally 
unreasonable to assume that one and the same comparison approach will be suitable for comparative 
evaluation of all the QAs involved. In most instances, tailored approaches may be required to reflect 
the mentioned diversity in QAs.  
For the case that adequate statistical frameworks can be identified and applied for the comparison of 
more than one QA of interest, an a priori specified concept ('overall success criterion') is recommended 
to describe the minimum requirements for a claim of similarity. Such a concept would ideally be put in 
an analysis plan which is prepared prior to sampling and conduct of the comparison analyses (refer to 
recommendations in Section 6).  
Any post-hoc justifications that observed (unexpectedly large) differences in one or more of the 
analysed QAs would have no or only minor impact on clinical outcome might eventually be seen to 
contradict preceding criticality assessment of QAs and/or an adequate definition of the similarity 
condition. In addition, restricting such a justification to the observed samples/batches is generally 
flawed when the aim is to make inferential conclusions on an underlying distributions (i.e. it would 
need to be justified that it can be concluded from the samples at hand that differences in underlying 
distributions are unimportant). 
The overall risk of a false positive conclusion on similarity following an inferential statistical comparison 
of several QAs will strongly depend on the assessments of operating characteristics that are possible to 
make for each separate QA data analysis. Whilst the quantification of this overall risk might be difficult,  
nonetheless it should be addressed already at the planning stage. Currently, only limited guidance can 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 15/21 
 
be given regarding the adequate choice of acceptable probability for a false positive decision for the 
comparison of QAs' data. The 5%-significance level established in the context of clinical trials can serve 
as an obvious first threshold for orientation. Generally, considerations concerning the risk of a false 
positive conclusion of similarity at the quality level become more important, the more this comparison 
is expected to carry pivotal evidence to support regulatory decision making. 
In this context, considerations on the probability for a false negative decision might eventually also 
become relevant from a planning perspective, as sample size constraints (e.g. low batch numbers) and 
associated risk for a false negative conclusion may lead to the need to use approaches other than 
inferential statistical comparison of QAs. 
5. Implications for settings where the comparison at the 
quality level is of particular relevance in regulatory 
decision-making 
This section provides reflections on a number of commonly occurring situations where a comparative 
evaluation at the quality level is highly relevant.  
The various settings described below share the challenge to somehow predefine an appropriate 
similarity condition. The definition of such an appropriate condition and the assessment of (maximum 
allowed) truly existing differences in QAs would benefit from a good understanding of the impact such 
differences could have on clinical outcome. The extent of knowledge regarding this association between 
differences at the quality level and clinical outcome (efficacy and/or safety aspects) will already drive 
the criticality assessment of the QAs. However, frequently there is a high degree of uncertainty 
concerning the impact of certain QAs on the clinical outcome. Hence, a considerable degree of 
arbitrariness might be unavoidable in practice. Therefore, submissions which use criticality 
assessments to inform the similarity analysis approach should include a discussion of the impact of 
QAs on clinical outcome in supporting the choices made.  
One frequently occurring limiting factor hampering the application of inferential statistical methodology 
is that sampling can be non-random. The samples used may therefore not be representative of an 
entire manufacturing process. In this case, any particular statistical model applied will fail to describe 
uncertainty in the desired manner, and the corresponding results have no inferential interpretation. 
Overall, it is up to the manufacturer to describe which similarity condition is assumed and which 
similarity criterion is adequate to check this condition. These decisions need to be tailored to each 
specific QA and the specific comparison (manufacturing change, generic, biosimilar, etc.). Ideally, the 
chosen similarity criterion is robust and minimises the risk of a false positive decision (i.e. has 
appropriate operating characteristics). A justification for the chosen similarity criterion should be 
provided in regulatory submissions, based on the considerations given below and in Section 4 above. 
5.1. Biologicals 
5.1.1. General issues relating to Comparability exercises 
Comparability exercises encompass both comparability after manufacturing changes and biosimilarity 
(see EMA Guideline on Similar Biological Medicinal Products1 which confirms that both situations fall 
under the same scientific umbrella).  
 
1 CHMP/437/04 Rev 1 as revised 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 16/21 
 
Comparability is not a stringently defined concept. According to ICH Q5E (CPMP/ICH/5721/03), 
‘comparable’ means that products have highly similar quality attributes before and after manufacturing 
process changes and that ‘no adverse impact on the safety or efficacy, including immunogenicity, of 
the drug product occurred.’ ICH Q5E (CPMP/ICH/5721/03)therefore does not require QAs to be 
identical or equivalent in a specifically stipulated inferential statistical sense. This flexible wording 
makes it possible to implement a similarity comparison approach which is most suitable to the specific 
situation, in line with the reflections offered in Section 4 of this Reflection Paper. This may include, but 
is not limited to, situations where differences may be acceptable if they represent improvements in 
safety (e.g. less impurities), or for example, formulation changes (which may induce intended or 
consequential changes in pH or osmolality), where requiring ‘similarity’ (including pre-specified 
similarity criteria) would defy the purpose of the change.  
Sampling considerations 
Sampling is one of the major differences between a manufacturing change and the biosimilarity 
situation. However, two common observations can be made, which relate to the impact of the control 
strategy on the data distribution: 
Firstly, shapes of underlying data distribution are often not adequately approximated by normal 
distribution because of truncation. Empirical data distributions are often truncated by the control 
strategy, especially for those QAs which are tested at release. In other words, certain (extreme) values 
can occur but will not be able to reach the final product because of the selection/truncation, even if 
they would be predicted by formal intervals. It is often assumed that the observed min-max range will 
converge towards the specification limit interval if a large number of samples is taken. However, this 
assumption may be questionable in certain cases, especially where the specification limit interval is 
wide compared to process capability. In such cases an untruncated empirical data distribution may be 
observed.  
Secondly, the number of ‘test batches’ (either post-manufacturing change or biosimilar batches) is 
usually relatively low. In this context, it has to be noted that there is no specific minimum number of 
required batches/units (e.g. 3 batches, as frequently suggested in practice for manufacturing changes) 
which could guarantee to capture the true underlying variability.  
Based on assumed manufacturing consistency, the first ’test batches’ could be interpreted as 
confirmatory that the new process yields ‘comparable’ batches; i.e. manufacturing consistency implies 
that the first produced batches (usually the process performance qualification [PPQ] batches) are 
representative for all future (not yet manufactured) batches. In addition, an adequate control strategy 
is a major contributor to manufacturing consistency. If all ‘test batches’ are not included in the 
comparability exercise, then the issue of sampling deserves special attention in any justification of a 
plan to utilise inferential statistical methodology for QA data comparison. In addition, it has to be noted 
that a very low number of available ’test batches’ could per se represent the limiting factor to carry out 
a meaningful inferential assessment, e.g. because the desired precision for interval estimation cannot 
be achieved. 
QA comparison framework 
As noted above, the similarity condition based on the underlying distributions should drive the choice 
of statistical methodology for the eventually applied data comparison.  
Different statistical approaches may be used for different QAs. The definition of the similarity condition 
is impacted by both the criticality of a specific QA and the physico-chemical properties described by it. 
Criticality in itself does not seem appropriate to drive the choice of statistical methodology; the 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 17/21 
 
physico-chemical properties described by the QA (which impact the observed or assumed distribution) 
and the established or suspected impact on clinical performance should determine the criterion. 
This has commonly been supported by using risk assessment tools to rank quality attributes in terms 
of their impact. It is noted that this approach is well developed in the assessment of biosimilarity; 
however, the scientific principles apply to all forms of comparability exercises, especially all types of 
major changes. Regardless of whether such ranking approaches are used, it is important to consider 
whether the chosen statistical similarity criterion is appropriate for the particular QA. Therefore the 
operating characteristics and risk of false positive conclusion should be considered and justified for the 
particular statistical method(s) for each QA. For most of the comparative analyses of QA data, the 
focus would usually be on two-sided comparative investigations. Exemptions could include potential 
improvements in specific QAs (e.g. reducing impurities) which might translate to safety advantages. 
Statistical equivalence of means is rarely attainable, but may also not be necessary; this criterion 
seems most suitable for parameters which are not batch-dependent, like e.g. binding constants of non-
glycosylated proteins to their receptors. For batch dependent parameters, the reflections with respect 
to various unequal but potentially acceptable distributions, as provided in Section 4.2, fully apply.  
Risks of false conclusions 
The question of adequate control of the risk for a false conclusion on similarity is of utmost importance. 
Hence, the exploration of operating characteristics of similarity criteria applied for QA data constitutes 
a key conceptual element to quantify the risk for a false conclusion on similarity. Therefore, in 
regulatory submissions, the operating characteristics of the chosen statistical approach should be 
outlined, and the risk of false positive and false negative conclusions clearly explained, given the 
description of the similarity condition, the choice of statistical similarity criterion and the number of 
batches sampled from the two manufacturing processes of interest.  
5.1.2. Specific issues relating to manufacturing changes  
The comparative evaluation of the quality of two product versions before and after a certain 
manufacturing change (including, but not limited to, transfers to other manufacturing sites, 
formulation changes, scale up, and changes during development) is a very common task during the 
lifecycle of a medicinal product.  
In contrast to the biosimilar setting (see next sub-section), the typical starting point in the pre/post- 
manufacturing setting is usually based on easy access to knowledge regarding the 'reference' – here 
the pre-change manufacturing process. Such knowledge usually relates to the whole history of the 
product's manufacturing, the sensitivity to changes in the production setup in terms of excursions of 
important QAs, sources of variability when measuring QAs, sensitivity of assays used, etc. This means 
that available knowledge concerning different causes for within- and between-batch variability can 
inform the statistical comparison approach. 
Sampling considerations 
Concerning sampling, the manufacturer usually has access to the data from pre-change batches. All 
these data, or a well-defined complete subset (e.g. all batches since the last major process change) 
can be used as the sample set. However, it commonly occurs that only routine release test results are 
available for all these pre-change batches, and that it is necessary to 'draw' representative samples for 
extended characterisation. It should be justified in regulatory submissions that the limited number of 
‘drawn’ batches is indeed representative. 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 18/21 
 
As noted previously, in many instances only a low number of batches produced consecutively after the 
manufacturing change are available for the comparison task. In this context, there is no specific 
minimum number of required batches/units (e.g. 3 batches) which can be assumed to be acceptable 
for the comparison task without further justification.  
5.1.3. Specific issues for Biosimilar setting 
QA investigation of the reference medicinal product  
In the biosimilar setting, a major challenge is the limited access to information regarding the 
manufacturing of the reference medicinal product. Hence, many sources of observed variability in the 
QAs of interest may remain obscure. Therefore, to demonstrate biosimilarity at the quality level, 
multiple reference product batches must be sampled and analysed to investigate the underlying data 
distributions of the reference product. Random sampling of reference product batches may be difficult 
to achieve; however, sampling should be such that obvious biases are avoided and the true range of 
variability can be estimated with some certainty.  
Sources of variability in the reference product data require special attention, and cases have been 
described in the past where significant shifts or drifts for the reference medicinal product's data 
distribution have been observed for relevant QAs (e.g. in the extreme case leading to non-overlapping 
clusters of reference medicinal product batch series). In such cases, the target for biosimilarity 
assessment might not be easily identifiable without further considerations regarding the reasons for 
the within-reference medicinal product manufacturing differences. For those QAs which are impacted 
by clearly identifiable shifts/drifts, in addition to analysing the reference dataset as a whole, it is 
advisable to conduct a statistical analysis of the pre- and post- shift ranges separately, in order to 
understand whether the biosimilar QAs are more closely aligned with the pre- or the post-shift profile. 
Similarity condition 
For each selected QA the Applicant must demonstrate that the biosimilar candidate has "a highly 
similar" quality profile compared to the reference medicinal product. However, there is no strict 
definition of what constitutes “highly similar” in a statistical context. Therefore, developers should 
firstly strive to gain an understanding regarding an agreeable similarity condition (as outlined in 
Section 4.2) for each QA. This would need to reflect the maximum allowed difference between 
underlying data distributions which would still result in a safety and efficacy profile comparable to the 
reference product. It is recognised that identifying the similarity condition may be challenging, as the 
impact of differences at the quality level on clinical outcome (efficacy/safety/immunogenicity) is often 
hard to predict or quantify. It is recognised that statistically significant differences may be clinically 
irrelevant in some cases. From a methodological viewpoint, the optimal approach would be one where 
failing the similarity criterion in the QA analysis would by definition imply a clinically meaningful 
difference (i.e. where the allowable difference is established beforehand as part of the similarity 
condition). In practice, as clinically allowable differences are extremely difficult to establish based on 
theoretical grounds only, it seems currently unavoidable to use empirical batch data for informing 
which differences are acceptable. In line with what has been stated above regarding risk assessments 
and QA classification, these batch data should be combined with available (non-)clinical data about e.g. 
the mechanism of action, to avoid too stringent similarity criteria for QAs which would have no 
reasonable correspondence to relevant clinical differences.  
In the biosimilar setting, any difference identified in any product characteristic could in principle be 
interpreted as a potential signal for non-similarity between the reference medicinal product and the 
biosimilar candidate. Nonetheless, it is recognised that the question in how far dissimilarity in QA data 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 19/21 
 
can be seen compliant with a biosimilarity claim may not be based on the outcome of a single 
statistical test, but rather taking the entire biosimilar data package as a whole.  
5.2. Small molecules 
5.2.1 Specific issues for abridged/hybrid applications 
Abridged or hybrid marketing authorisation applications for small molecules represent one further 
arena where data comparison at the quality level, including also on an ex-vivo/in-vitro data, could be 
of pivotal relevance for regulatory decision making. Locally-applied, locally-acting products represent 
one example where, under certain circumstances, similarity needs to be explored between a test- and 
a reference product. Examples are droplet-size comparison for aerosols/inhalation products or 
comparative assessment of data from permeability assays for transdermal products. 
The Note for Guidance on the clinical requirements for locally applied, locally acting products 
containing known constituents (CPMP/EWP/239/95 final) mentions options to waive therapeutic 
equivalence trials if other models can be justified to generate sufficient evidence to support an 
equivalence claim. Similar to that, Appendix II of the CHMP Guideline on the Investigation of 
Bioequivalence (CPMP/EWP/QWP/1401/98 Rev.1/Corr) describes biowaiver conditions for the 
development of special pharmaceutical forms (e.g. eye drops, nasal sprays or cutaneous solutions). 
Here, waiver criteria are based on comparison analysis results involving data from QAs of the test and 
the reference product. In these documents no further detailed guidance regarding the methodological 
framework for the actual analysis of equivalence are provided. In lack of such guidance, equivalence 
criteria agreed to be suitable to compare PK data in the immediate release products’ bioequivalence 
setting (estimating confidence intervals for the ratio of means and comparing to an acceptance range 
of 80%-125%) are occasionally suggested to support a similarity claim. However, in absence of 
additional (preceding) considerations what would constitute the similarity condition (see Section 4.2), 
the evaluation of operating characteristics of such criteria falls short. 
Furthermore, the CHMP Guideline on the pharmacokinetic and clinical evaluation of modified release 
dosage forms (EMA/CHMP/EWP/280/96, Rev1) contains considerations regarding similarity of 
dissolution profiles regulating waivers and the need for bracketing approaches, but neither include 
stipulations regarding a broadly agreeable similarity condition nor further recommendations on 
reasonable approaches for using inferential statistical methodology.  
The comparative analysis of dissolution profiles between two (versions of a) medicinal product(s) can 
be seen as a special case under the scope of this reflection paper. This special case is characterised by 
the fact that there is only one QA of interest, i.e. dissolution over time. As mentioned in Appendix I of 
the CHMP Guideline on the Investigation of Bioequivalence (CPMP/EWP/QWP/1401/98 Rev.1/Corr), 
comparative dissolution investigations are relevant for the justification to waive bioequivalence studies. 
In this context, the guidance introduces dissolution similarity assessment as 'Bioequivalence surrogate 
inference', which actually implies that inferential statistical methodology would ideally be applied to 
e.g. infer a similarity-in-dissolution claim from the tablet sample to the whole tablet population (all 
tablets ever produced by a given manufacturing process). The guideline recommendation towards a 
definition of the similarity condition is a 10% limit for the mean dissolution over time. The suggested 
criterion to investigate of whether this condition holds is the f2 metric, where differences in sample 
averages are suggested to be used for deriving a distance measure between reference and test 
compound. Alternative options for dissolution similarity assessment to handle situations where the f2 
metric is not considered suitable comprise other model-independent distance metrics as well as model-
based investigations of dissolution profile differences. It is interesting to note that, when following such 
alternative comparison strategies, the assessment of similarity in dissolution may go beyond the sole 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 20/21 
 
evaluation of distribution means. This aspect confirms the observations described in Section 4.2 that 
common agreement around a broadly accepted similarity condition is an important pre-requisite for 
similarity investigations based on QAs’ data. 
As for all cases mentioned above, only limited guidance exists from the methodological point of view, 
the fundamental requirements as introduced in Section 4 would need to be considered, given an 
model/experiment identified to support a similarity claim based on empirical QAs’ sample data. Some 
of the aspects described above for the biosimilarity setting to build a statistical framework might also 
be applicable to the broader field of abridged/hybrid applications. This might however also pertain to 
the challenges to attribute observed variation in the empirical sample data to potential sources of 
variability. 
6. Quality Attributes data comparison protocol 
Against the background of the topics discussed in this reflection paper, the concluding recommendation 
is given to pre-plan a certain QA data comparison task as far as possible. One reasonable option is to 
prepare a dedicated planning document for this purpose, e.g. a ‘Quality Attributes Data Comparison 
Protocol’. With such a document, the data comparison task would ideally be contextualized with the 
whole product development, indicating and weighing the importance of demonstrating that two 
products (or manufacturing processes) are similar at a quality level. It is important to note that only 
adequate pre-planning will protect against the potential criticism related to data-driven analyses and 
biased post hoc decisions. Regardless of the actual (regulatory) context of a certain QA data 
comparability task, the following guiding principles for planning the content of a comparison protocol 
can be given: 
• 
The objective as well as the context of the QA data comparison should be clearly stated. 
Descriptions would ideally include considerations regarding potential consequences for the two 
possible outcomes of the comparative investigation, namely either that similarity could be 
demonstrated, or not demonstrated. Examples for consequences based on demonstrated 
similarity are: continuation of manufacturing after an implemented manufacturing change, 
moving ahead within a biosimilar comparison task to the next stage in the recommended 
stepwise manner, or even to waive a clinical trial based on demonstrated similarity at the 
quality level (e.g. similarity in dissolution demonstrated).  
• 
Considerations should be made regarding which aspects of the comparability task could be 
approached in a prospective manner. Also, unavoidable limitations and feasibility issues in 
relation to the conduct of comparative QA data analyses could be described. Even if the nature 
of the data comparison remains retrospective, several aspects of the comparison task could 
nonetheless be pre-planned before the actual data for inclusion in the analysis is collected. 
These aspects could cover in particular: the set of QAs subject to analysis, 
definition/elaboration of the similarity condition, the sampling strategy, the similarity criterion 
applied per QA.  
• 
Elaborations concerning the similarity condition (see Section 4.2) need to be contained in the 
comparison protocol as a basis for any inferential statistical framework of QA data comparison. 
In this context, a discussion is required on whether it would be meaningful to assume the same 
similarity condition for all QAs involved in the similarity assessment. 
• 
Representativeness of samples analysed is the key pre-requisite for a meaningful interpretation 
of results in inferential statistical methodology. Hence, considerations concerning the sampling 
strategy are of utmost importance, and are expected to include the decision regarding what 
the unit of observation will be: manufacturing batch, vial/pool of liquid formulation, tablet, etc. 
 
Reflection paper on statistical methodology for the comparative assessment of quality 
attributes in drug development  
 
EMA/CHMP/138502/2017  
Page 21/21 
 
Decisions in this regard would ideally also be driven by the knowledge of potential sources of 
variability in the QA data. Descriptions of sampling plans need to also include justifications 
regarding exclusion (non-selection) of batches/units, which were principally available for the 
comparison task. It is acknowledged that in some situations investigations will be limited to 
non-random samples or to samples for which information regarding the origin or specific 
manufacturing circumstances cannot be retrieved. In any case, regulatory assessors would 
ultimately need to verify that selection of batches/units was not data-driven.  
• 
For each (Critical)QA which is selected for comparative data analysis, a similarity criterion – 
according to the descriptions in Section 4.3 – needs to be pre-specified. For QAs with similar 
scales of measurement and similar distributional assumptions, the same similarity criterion 
could be planned, in case the same similarity condition applies. Ideally, the choice of similarity 
criteria is based on investigations of operating characteristics with special focus on the risk for 
a false positive decision of similarity. 
• 
The comparison protocol would ideally also contain a description of how the combined 
comparative evaluation of several QAs would eventually translate into an overall conclusion of 
similarity at the quality level. 