 
 
 
European Medicines Agency 
 
7 Westferry Circus, Canary Wharf, London, E14 4HB, UK 
Tel. (44-20) 74 18 85 75   Fax (44-20) 75 23 70 40 
E-mail: mail@emea.eu.int     http://www.emea.eu.int 
EMEA 2006 Reproduction and/or distribution of this document is authorised for non commercial purposes only provided the EMEA is acknowledged 
May 2000 
CPMP/ICH/367/96  
 
 
 
ICH Topic Q 6 A 
Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and 
New Drug Products: Chemical Substances 
 
 
 
Step 5 
 
 
 
NOTE FOR GUIDANCE SPECIFICATIONS: TEST PROCEDURES AND 
ACCEPTANCE CRITERIA FOR NEW DRUG SUBSTANCES AND NEW DRUG 
PRODUCTS:  CHEMICAL SUBSTANCES 
(CPMP/ICH/367/96) 
 
 
 
 
  TRANSMISSION TO CPMP 
September 1997 
TRANSMISSION TO INTERESTED PARTIES 
September 1997 
DEADLINE FOR COMMENTS 
March 1998 
FINAL APPROVAL BY CPMP 
November 1999 
DATE FOR COMING INTO OPERATION 
May 2000 
 
 
 
© EMEA 2006 
 
2 
SPECIFICATIONS: TEST PROCEDURES AND ACCEPTANCE CRITERIA FOR 
NEW DRUG SUBSTANCES AND NEW DRUG PRODUCTS: CHEMICAL 
SUBSTANCES 
 
 
TABLE OF CONTENTS 
TRANSMISSION TO INTERESTED PARTIES....................................................................1 
1.  
INTRODUCTION.........................................................................................................3 
1.1  
OBJECTIVE OF THE GUIDELINE........................................................................................3 
1.2  
BACKGROUND................................................................................................................3 
1.3  
SCOPE OF THE GUIDELINE...............................................................................................3 
2.  
GENERAL CONCEPTS...............................................................................................4 
2.1.  PERIODIC OR SKIP TESTING.............................................................................................4 
2.2.  RELEASE VS. SHELF-LIFE ACCEPTANCE CRITERIA ...........................................................4 
2.3  
IN-PROCESS TESTS..........................................................................................................5 
2.4.  DESIGN AND DEVELOPMENT CONSIDERATIONS...............................................................5 
2.5.  LIMITED DATA AVAILABLE AT FILING.............................................................................5 
2.6 
PARAMETRIC RELEASE ...................................................................................................5 
2.7  
ALTERNATIVE PROCEDURES...........................................................................................6 
2.8  
PHARMACOPOEIAL TESTS AND ACCEPTANCE CRITERIA ..................................................6 
2.9  
EVOLVING TECHNOLOGIES .............................................................................................6 
2.10  
IMPACT OF DRUG SUBSTANCE ON DRUG PRODUCT SPECIFICATIONS.............................7 
2.11  REFERENCE STANDARD .................................................................................................7 
3.  
GUIDELINES ...............................................................................................................7 
3.1  
SPECIFICATIONS: DEFINITION AND JUSTIFICATION .........................................................7 
3.1.1. DEFINITION OF SPECIFICATIONS......................................................................................7 
3.1.2. JUSTIFICATION OF SPECIFICATIONS.................................................................................7 
3.2  
UNIVERSAL TESTS/CRITERIA ..........................................................................................8 
3.2.1. NEW DRUG SUBSTANCES ................................................................................................8 
3.2.2. NEW DRUG PRODUCTS ....................................................................................................9 
3.3 SPECIFIC TESTS/CRITERIA .................................................................................................10 
3.3.1. NEW DRUG SUBSTANCES ..............................................................................................10 
3.3.2. NEW DRUG PRODUCTS ..................................................................................................12 
4.  
GLOSSARY (THE FOLLOWING DEFINITIONS ARE PRESENTED FOR THE 
PURPOSE OF THIS GUIDELINE) .....................................................................................19 
5. REFERENCES...............................................................................................................21 
6.  
ATTACHMENTS: DECISION TREES #1 THROUGH #8.......................................21 
 
 
© EMEA 2006 
 
3 
 
1.  
INTRODUCTION 
1.1  Objective of the guideline 
This guideline is intended to assist to the extent possible, in the establishment of a single set 
of global specifications for new drug substances and new drug products. It provides guidance 
on the setting and justification of acceptance criteria and the selection of test procedures for 
new drug substances of synthetic chemical origin, and new drug products produced from 
them, which have not been registered previously in the United States, the European Union, or 
Japan. 
1.2  Background 
A specification is defined as a list of tests, references to analytical procedures, and appropriate 
acceptance criteria, which are numerical limits, ranges, or other criteria for the tests described. 
It establishes the set of criteria to which a drug substance or drug product should conform to 
be considered acceptable for its intended use. "Conformance to specifications" means that the 
drug substance and / or drug product, when tested according to the listed analytical 
procedures, will meet the listed acceptance criteria.  Specifications are critical quality 
standards that are proposed and justified by the manufacturer and approved by regulatory 
authorities as conditions of approval.  
Specifications are one part of a total control strategy for the drug substance and drug product 
designed to ensure product quality and consistency. Other parts of this strategy include 
thorough product characterization during development, upon which specifications are based, 
and adherence to Good Manufacturing Practices; e.g., suitable facilities, a validated 
manufacturing process, validated test procedure, raw material testing, in-process testing, 
stability testing, etc. 
Specifications are chosen to confirm the quality of the drug substance and drug product rather 
than to establish full characterization, and should focus on those characteristics found to be 
useful in ensuring the safety and efficacy of the drug substance and drug product. 
1.3  Scope of the guideline 
The quality of drug substances and drug products is determined by their design, development, 
in-process controls, GMP controls, and process validation, and by specifications applied to 
them throughout development and manufacture. This guideline addresses specifications, i.e., 
those tests, procedures, and acceptance criteria which play a major role in assuring the quality 
of the new drug substance and new drug product at release and during shelf life. 
Specifications are an important component of quality assurance, but are not its only 
component. All of the considerations listed above are necessary to ensure consistent 
production of drug substances and drug products of high quality. 
This guideline addresses only the marketing approval of new drug products (including 
combination products) and, where applicable, new drug substances; it does not address drug 
substances or drug products during the clinical research stages of drug development.  This 
guideline may be applicable to synthetic and semi-synthetic antibiotics and synthetic peptides 
of low molecular weight; however, it is not sufficient to adequately describe specifications of 
higher molecular weight peptides and polypeptides, and biotechnological/biological products. 
The ICH Guideline Specifications: Test Procedures and Acceptance Criteria for 
Biotechnological/Biological Products addresses guideline specifications, tests and procedures 
for biotechnological/biological products.  Radiopharmaceuticals, products of fermentation, 
oligonucleotides, herbal products and crude products of animal or plant origin are similarly 
not covered. 
 
© EMEA 2006 
 
4 
Guidance is provided with regard to acceptance criteria which should be established for all 
new drug substances and new drug products, i.e. universal acceptance criteria, and those that 
are considered specific to individual drug substances and / or dosage forms. This guideline 
should not be considered all encompassing.  New analytical technologies, and modifications 
to existing technology, are continually being developed.  Such technologies should be used 
when justified. 
Dosage forms addressed in this guideline include solid oral dosage forms, liquid oral dosage 
forms, and parenterals (small and large volume). This is not meant to be an all-inclusive list, 
or to limit the number of dosage forms to which this guideline applies. The dosage forms 
presented serve as models, which may be applicable to other dosage forms which have not 
been discussed. The extended application of the concepts in this guideline to other dosage 
forms, e.g., to inhalation dosage forms (powders, solutions, etc.), to topical formulations 
(creams, ointments, gels), and to transdermal systems, is encouraged.  
2.  
GENERAL CONCEPTS 
The following concepts are important in the development and setting of harmonized 
specifications. They are not universally applicable, but each should be considered in particular 
circumstances. This guideline presents a brief definition of each concept and an indication of 
the circumstances under which it may be applicable. Generally, proposals to implement these 
concepts should be justified by the applicant and approved by the appropriate regulatory 
authority before being put into effect. 
2.1.  Periodic or skip testing 
Periodic or skip testing is the performance of specified tests at release on pre-selected batches 
and / or at predetermined intervals, rather than on a batch-to-batch basis with the 
understanding that those batches not being tested still must meet all acceptance criteria 
established for that product. This represents a less than full schedule of testing and should 
therefore be justified and presented to and approved by the regulatory authority prior to 
implementation.  This concept may be applicable to, for example, residual solvents and 
microbiological testing, for solid oral dosage forms. It is recognized that only limited data 
may be available at the time of submission of an application (see section 2.5). This concept 
should therefore generally be implemented post-approval.  When tested, any failure to meet 
acceptance criteria established for the periodic test should be handled by proper notification of 
the appropriate regulatory authority(ies).  If these data demonstrate a need to restore routine 
testing, then batch by batch release testing should be reinstated. 
2.2.  Release vs. shelf-life acceptance criteria 
The concept of different acceptance criteria for release vs. shelf-life specifications applies to 
drug products only; it pertains to the establishment of more restrictive criteria for the release 
of a drug product than are applied to the shelf-life. Examples where this may be applicable 
include assay and impurity (degradation product) levels. In Japan and the United States, this 
concept may only be applicable to in-house criteria, and not to the regulatory release criteria.   
Thus, in these regions, the regulatory acceptance criteria are the same from release throughout 
shelf-life; however, an applicant may choose to have tighter in-house limits at the time of 
release to provide increased assurance to the applicant that the product will remain within the 
regulatory acceptance criterion throughout its shelf-life.  In the European Union there is a 
regulatory requirement for distinct specifications for release and for shelf-life where different. 
 
© EMEA 2006 
 
5 
2.3  In-process tests 
In-process tests, as presented in this guideline, are tests which may be performed during the 
manufacture of either the drug substance or drug product, rather than as part of the formal 
battery of tests which are conducted prior to release. 
In-process tests which are only used for the purpose of adjusting process parameters within an 
operating range, e.g., hardness and friability of tablet cores which will be coated and 
individual tablet weights, are not included in the specification. 
Certain tests conducted during the manufacturing process, where the acceptance criterion is 
identical to or tighter than the release requirement, (e.g., pH of a solution) may be sufficient to 
satisfy specification requirements when the test is included in the specification.  However, this 
approach should be validated to show that test results or product performance characteristics 
do not change from the in-process stage to finished product. 
2.4.  Design and development considerations 
The experience and data accumulated during the development of a new drug substance or 
product should form the basis for the setting of specifications. It may be possible to propose 
excluding or replacing certain tests on this basis. Some examples are: 
 
• 
microbiological testing for drug substances and solid dosage forms which have 
been shown during development not to support microbial viability or growth 
(see Decision Trees #6 and #8). 
• 
extractables from product containers where it has been reproducibly shown that 
either no extractables are found in the drug product or the levels meet accepted 
standards for safety. 
• 
particle size testing may fall into this category, may be performed as an in-process 
test, or may be performed as a release test, depending on its relevance to product 
performance. 
• 
dissolution testing for immediate release solid oral drug products made from 
highly water soluble drug substances may be replaced by disintegration testing, if 
these products have been demonstrated during development to have consistently 
rapid drug release characteristics (see Decision Trees #7(1) through #7(2)). 
2.5.  Limited data available at filing 
It is recognized that only a limited amount of data may be available at the time of filing, 
which can influence the process of setting acceptance criteria. As a result it may be necessary 
to propose revised acceptance criteria as additional experience is gained with the manufacture 
of a particular drug substance or drug product (example: acceptance limits for a specific 
impurity). The basis for the acceptance criteria at the time of filing should necessarily focus 
on safety and efficacy. 
When only limited data are available, the initially approved tests and acceptance criteria 
should be reviewed as more information is collected, with a view towards possible 
modification. This could involve loosening, as well as tightening, acceptance criteria as 
appropriate. 
2.6 
Parametric release 
Parametric release can be used as an operational alternative to routine release testing for the 
drug product in certain cases when approved by the regulatory authority. Sterility testing for 
terminally sterilized drug products is one example. In this case, the release of each batch is 
based on satisfactory results from monitoring specific parameters, e.g., temperature, pressure, 
 
© EMEA 2006 
 
6 
and time during the terminal sterilization phase(s) of drug product manufacturing. These 
parameters can generally be more accurately controlled and measured, so that they are more 
reliable in predicting sterility assurance than is end-product sterility testing.  Appropriate 
laboratory tests (e.g., chemical or physical indicator) may be included in the parametric 
release program.  It is important to note that the sterilization process should be adequately 
validated before parametric release is proposed and maintenance of a validated state should be 
demonstrated by revalidation at established intervals. When parametric release is performed, 
the attribute which is indirectly controlled (e.g., sterility), together with a reference to the 
associated test procedure, still should be included in the specifications. 
2.7  Alternative procedures 
Alternative procedures are those which may be used to measure an attribute when such 
procedures control the quality of the drug substance or drug product to an extent that is 
comparable or superior to the official procedure. Example: for tablets that have been shown 
not to degrade during manufacture, it may be permissible to use a spectrophotometric 
procedure for release as opposed to the official procedure, which is chromatographic. 
However, the chromatographic procedure should still be used to demonstrate compliance with 
the acceptance criteria during the shelf-life of the product. 
2.8  Pharmacopoeial tests and acceptance criteria 
References to certain procedures are found in pharmacopoeias in each region.  Wherever they 
are appropriate, pharmacopoeial procedures should be utilized.  Whereas differences in 
pharmacopoeial procedures and/or acceptance criteria have existed among the regions, a 
harmonized specification is possible only if the procedures and acceptance criteria defined are 
acceptable to regulatory authorities in all regions. 
The full utility of this Guideline is dependent on the successful completion of harmonization 
of pharmacopoeial procedures for several attributes commonly considered in the specification 
for new drug substances or new drug products.  The Pharmacopoeial Discussion Group 
(PDG) of the European Pharmacopoeia, the Japanese Pharmacopoeia, and the United States 
Pharmacopeia has expressed a commitment to achieving harmonization of the procedures in a 
timely fashion. 
Where harmonization has been achieved, an appropriate reference to the harmonized 
procedure and acceptance criteria is considered acceptable for a specification in all three 
regions.  For example, after harmonization sterility data generated using the JP procedure, as 
well as the JP procedure itself and its acceptance criteria, are considered acceptable for 
registration in all three regions.  To signify the harmonized status of these procedures, the 
pharmacopoeias have agreed to include a statement in their respective texts which indicates 
that the procedures and acceptance criteria from all three pharmacopoeias are considered 
equivalent and are, therefore, interchangeable. 
Since the overall value of this Guideline is linked to the extent of harmonization of the 
analytical procedures and acceptance criteria of the pharmacopoeias, it is agreed by the 
members of the Q6A expert working group that none of the three pharmacopoeias should 
change a harmonized monograph unilaterally.  According to the PDG procedure for the 
revision of harmonized monographs and chapters, “no pharmacopoeia shall revise unilaterally 
any monograph or chapter after sign-off or after publication.” 
2.9  Evolving technologies 
New analytical technologies, and modifications to existing technology, are continually being 
developed. Such technologies should be used when they are considered to offer additional 
assurance of quality, or are otherwise justified. 
 
© EMEA 2006 
 
7 
2.10  Impact of drug substance on drug product specifications 
In general, it should not be necessary to test the drug product for quality attributes uniquely 
associated with the drug substance. Example: it is normally not considered necessary to test 
the drug product for synthesis impurities which are controlled in the drug substance and are 
not degradation products. Refer to the ICH Guideline Impurities in New Drug Products for 
detailed information. 
2.11  Reference standard 
A reference standard, or reference material, is a substance prepared for use as the standard in 
an assay, identification, or purity test.  It should have a quality appropriate to its use. It is 
often characterized and evaluated for its intended purpose by additional procedures other than 
those used in routine testing.  For new drug substance reference standards intended for use in 
assays, the impurities should be adequately identified and / or controlled, and purity should be 
measured by a quantitative procedure.  
3.  
GUIDELINES 
3.1  Specifications: Definition and justification 
3.1.1. Definition of specifications 
A specification is defined as a list of tests, references to analytical procedures, and appropriate 
acceptance criteria which are numerical limits, ranges, or other criteria for the tests described. 
It establishes the set of criteria to which a new drug substance or new drug product should 
conform to be considered acceptable for its intended use. "Conformance to specifications" 
means that the drug substance and / or drug product, when tested according to the listed 
analytical procedures, will meet the listed acceptance criteria. Specifications are critical 
quality standards that are proposed and justified by the manufacturer and approved by 
regulatory authorities as conditions of approval. 
It is possible that, in addition to release tests, a specification may list in-process tests as 
defined in 2.3, periodic (skip) tests, and other tests which are not always conducted on a 
batch-by-batch basis. In such cases the applicant should specify which tests are routinely 
conducted batch-by-batch, and which tests are not, with an indication and justification of the 
actual testing frequency. In this situation, the drug substance and / or drug product should 
meet the acceptance criteria if tested. 
It should be noted that changes in the specification after approval of the application may need 
prior approval by the regulatory authority. 
3.1.2. Justification of specifications 
When a specification is first proposed, justification should be presented for each procedure 
and each acceptance criterion included. The justification should refer to relevant development 
data, pharmacopoeial standards, test data for drug substances and drug products used in 
toxicology and clinical studies, and results from accelerated and long term stability studies, as 
appropriate. Additionally, a reasonable range of expected analytical and manufacturing 
variability should be considered. It is important to consider all of this information. 
Approaches other than those set forth in this guideline may be applicable and acceptable. The 
applicant should justify alternative approaches. Such justification should be based on data 
derived from the new drug substance synthesis and/or the new drug product manufacturing 
process. This justification may consider theoretical tolerances for a given procedure or 
acceptance criterion, but the actual results obtained should form the primary basis for 
whatever approach is taken. 
 
© EMEA 2006 
 
8 
Test results from stability and scale-up / validation batches, with emphasis on the primary 
stability batches, should be considered in setting and justifying specifications. If multiple 
manufacturing sites are planned, it may be valuable to consider data from these sites in 
establishing the initial tests and acceptance criteria. This is particularly true when there is 
limited initial experience with the manufacture of the drug substance or drug product at any 
particular site. If data from a single representative manufacturing site are used in setting tests 
and acceptance criteria, product manufactured at all sites should still comply with these 
criteria. 
Presentation of test results in graphic format may be helpful in justifying individual 
acceptance criteria, particularly for assay values and impurity levels. Data from development 
work should be included in such a presentation, along with stability data available for new 
drug substance or new drug product batches manufactured by the proposed commercial 
processes. Justification for proposing exclusion of a test from the specification should be 
based on development data and on process validation data (where appropriate). 
3.2  Universal tests/criteria  
Implementation of the recommendations in the following section should take into account the 
ICH Guidelines Text on Validation of Analytical Procedures and Validation of Analytical 
Procedures: Methodology. 
3.2.1. New drug substances 
The following tests and acceptance criteria are considered generally applicable to all new drug 
substances. 
a) Description: a qualitative statement about the state (e.g. solid, liquid) and color of the new 
drug substance. If any of these characteristics change during storage, this change should be 
investigated and appropriate action taken.  
b) Identification: identification testing should optimally be able to discriminate between 
compounds of closely related structure which are likely to be present. Identification tests 
should be specific for the new drug substance, e.g., infrared spectroscopy. Identification 
solely by a single chromatographic retention time, for example, is not regarded as being 
specific.  However, the use of two chromatographic procedures, where the separation is based 
on different principles or a combination of tests into a single procedure, such as HPLC/UV 
diode array, HPLC/MS, or GC/MS is generally acceptable.  If the new drug substance is a 
salt, identification testing should be specific for the individual ions.  An identification test that 
is specific for the salt itself should suffice. 
New drug substances which are optically active may also need specific identification testing 
or performance of a chiral assay.  Please refer to 3.3.1.d) in this Guideline for further 
discussion of this topic. 
c) Assay: A specific, stability-indicating procedure should be included to determine the 
content of the new drug substance. In many cases it is possible to employ the same procedure 
(e.g., HPLC) for both assay of the new drug substance and quantitation of impurities. 
In cases where use of a non-specific assay is justified, other supporting analytical procedures 
should be used to achieve overall specificity. For example, where titration is adopted to assay 
the drug substance, the combination of the assay and a suitable test for impurities should be 
used. 
d) Impurities: Organic and inorganic impurities and residual solvents are included in this 
category. Refer to the ICH Guidelines Impurities in New Drug Substances and Residual 
Solvents in Pharmaceuticals for detailed information.  
 
© EMEA 2006 
 
9 
Decision tree #1 addresses the extrapolation of meaningful limits on impurities from the body 
of data generated during development. At the time of filing it is unlikely that sufficient data 
will be available to assess process consistency. Therefore it is considered inappropriate to 
establish acceptance criteria which tightly encompass the batch data at the time of filing. (see 
section 2.5) 
3.2.2. New drug products 
The following tests and acceptance criteria are considered generally applicable to all new drug 
products: 
a) Description: A qualitative description of the dosage form should be provided (e.g., size, 
shape, and color). If any of these characteristics change during manufacture or storage, this 
change should be investigated and appropriate action taken. The acceptance criteria should 
include the final acceptable appearance. If color changes during storage, a quantitative 
procedure may be appropriate. 
b) Identification: Identification testing should establish the identity of the new drug 
substance(s) in the new drug product and should be able to discriminate between compounds 
of closely related structure which are likely to be present. Identity tests should be specific for 
the new drug substance, e.g., infrared spectroscopy.  Identification solely by a single 
chromatographic retention time, for example, is not regarded as being specific.  However, the 
use of two chromatographic procedures, where the separation is based on different principles, 
or combination of tests into a single procedure, such as HPLC/UV diode array, HPLC/MS, or 
GC/MS, is generally acceptable. 
c) Assay: A specific, stability-indicating assay to determine strength (content) should be 
included for all new drug products. In many cases it is possible to employ the same procedure 
(e.g., HPLC) for both assay of the new drug substance and quantitation of impurities. Results 
of content uniformity testing for new drug products can be used for quantitation of drug 
product strength, if the methods used for content uniformity are also appropriate as assays. 
In cases where use of a non-specific assay is justified, other supporting analytical procedures 
should be used to achieve overall specificity. For example, where titration is adopted to assay 
the drug substance for release, the combination of the assay and a suitable test for impurities 
can be used.   A specific procedure should be used when there is evidence of excipient 
interference with the non-specific assay.  
d) Impurities: Organic and inorganic impurities (degradation products) and residual solvents 
are included in this category.  Refer to the ICH Guidelines Impurities in New Drug Products 
and Residual Solvents for detailed information.    
Organic impurities arising from degradation of the new drug substance and impurities that 
arise during the manufacturing process for the drug product should be monitored in the new 
drug product. Acceptance limits should be stated for individual specified degradation 
products, which may include both identified and unidentified degradation products as 
appropriate, and total degradation products. Process impurities from the new drug substance 
synthesis are normally controlled during drug substance testing, and therefore are not included 
in the total impurities limit. However, when a synthesis impurity is also a degradation 
product, its level should be monitored and included in the total degradation product limit.  
When it has been conclusively demonstrated via appropriate analytical methodology, that the 
drug substance does not degrade in the specific formulation, and under the specific storage 
conditions proposed in the new drug application, degradation product testing may be reduced 
or eliminated upon approval by the regulatory authorities. 
Decision tree #2 addresses the extrapolation of meaningful limits on degradation products 
from the body of data generated during development. At the time of filing it is unlikely that 
 
© EMEA 2006 
 
10 
sufficient data will be available to assess process consistency. Therefore it is considered 
inappropriate to establish acceptance criteria which tightly encompass the batch data at the 
time of filing. (see section 2.5) 
3.3 Specific tests/criteria 
In addition to the universal tests listed above, the following tests may be considered on a case 
by case basis for drug substances and/or drug products. Individual tests/criteria should be 
included in the specification when the tests have an impact on the quality of the drug 
substance and drug product for batch control. Tests other than those listed below may be 
needed in particular situations or as new information becomes available.  
3.3.1. New drug substances 
a) Physicochemical properties: These are properties such as pH of an aqueous solution, 
melting point / range, and refractive index. The procedures used for the measurement of these 
properties are usually unique and do not need much elaboration, e.g., capillary melting point, 
Abbé refractometry. The tests performed in this category should be determined by the 
physical nature of the new drug substance and by its intended use.  
b) Particle size: For some new drug substances intended for use in solid or suspension drug 
products, particle size can have a significant effect on dissolution rates, bioavailability, and / 
or stability. In such instances, testing for particle size distribution should be carried out using 
an appropriate procedure, and acceptance criteria should be provided. 
Decision tree #3 provides additional guidance on when particle size testing should be 
considered.  
c) Polymorphic forms: Some new drug substances exist in different crystalline forms which 
differ in their physical properties. Polymorphism may also include solvation or hydration 
products (also known as pseudopolymorphs) and amorphous forms.  Differences in these 
forms could, in some cases, affect the quality or performance of the new drug products. In 
cases where differences exist which have been shown to affect drug product performance, 
bioavailability or stability, then the appropriate solid state should be specified.  
Physicochemical measurements and techniques are commonly used to determine whether 
multiple forms exist.  Examples of these procedures are: melting point (including hot-stage 
microscopy), solid state IR, X-ray powder diffraction, thermal analysis procedures (like DSC, 
TGA and DTA), Raman spectroscopy, optical microscopy, and solid state NMR. 
Decision trees #4(1) through 4(3) provide additional guidance on when, and how, 
polymorphic forms should be monitored and controlled. 
Note: These decision trees should be followed sequentially. Trees 1 and 2 consider whether 
polymorphism is exhibited by the drug substance, and whether the different polymorphic 
forms can affect performance of the drug product. Tree 3 should only be applied when 
polymorphism has been demonstrated for the drug substance, and shown to affect these 
properties. Tree 3 considers the potential for change in polymorphic forms in the drug 
product, and whether such a change has any effect on product performance.  
It is generally technically very difficult to measure polymorphic changes in drug products. A 
surrogate test (e.g., dissolution) (see Decision tree 4(3)) can generally be used to monitor 
product performance, and polymorph content should only be used as a test and acceptance 
criterion of last resort. 
d) Tests for chiral new drug substances: Where a new drug substance is predominantly one 
enantiomer, the opposite enantiomer is excluded from the qualification and identification 
thresholds given in the ICH Guidelines on Impurities in New Drug Substances and Impurities 
in New Drug Products because of practical difficulties in quantifying it at those levels.  
 
© EMEA 2006 
 
11 
However, that impurity in the chiral new drug substance and the resulting new drug product(s) 
should otherwise be treated according to the principles established in those Guidelines. 
Decision tree #5 summarizes when and if chiral identity tests, impurity tests, and assays may 
be needed for both new drug substances and new drug products, according to the following 
concepts:  
 
Drug Substance: Impurities. For chiral drug substances which are developed as a single 
enantiomer, control of the other enantiomer should be considered in the same manner as 
for other impurities. However, technical limitations may preclude the same limits of 
quantification or qualification from being applied.  Assurance of control also could be 
given by appropriate testing of a starting material or intermediate, with suitable 
justification.  
 
Assay. An enantioselective determination of the drug substance should be part of the 
specification. It is considered acceptable for this to be achieved either through use of a 
chiral assay procedure or by the combination of an achiral assay together with 
appropriate methods of controlling the enantiomeric impurity. 
 
Identity. For a drug substance developed as a single enantiomer, the identity test(s) 
should be capable of distinguishing both enantiomers and the racemic mixture.  For a 
racemic drug substance, there are generally two situations where a stereospecific 
identity test is appropriate for release/acceptance testing: 1) where there is a significant 
possibility that the enantiomer might be substituted for the racemate, or 2) when there is 
evidence that preferential crystallization may lead to unintentional production of a non-
racemic mixture. 
 
Drug Product: Degradation products. Control of the other enantiomer in a drug product 
is considered necessary unless racemization has been shown to be insignificant during 
manufacture of the dosage form, and on storage. 
 
Assay: An achiral assay may be sufficient where racemization has been shown to be 
insignificant during manufacture of the dosage form, and on storage.  Otherwise a chiral 
assay should be used, or alternatively, the combination of an achiral assay plus a 
validated procedure to control the presence of the opposite enantiomer may be used. 
 
Identity: A stereospecific identity test is not generally needed in the drug product 
release specification.  When racemization is insignificant during manufacture of the 
dosage form, and on storage, stereospecific identity testing is more appropriately 
addressed as part of the drug substance specification.  When racemization in the dosage 
form is a concern, chiral assay or enantiomeric impurity testing of the drug product will 
serve to verify identity. 
e) Water content: This test is important in cases where the new drug substance is known to be 
hygroscopic or degraded by moisture or when the drug substance is known to be a 
stoichiometric hydrate. The acceptance criteria may be justified with data on the effects of 
hydration or moisture absorption. In some cases, a Loss on Drying procedure may be 
considered adequate; however, a detection procedure that is specific for water (e.g., Karl 
Fischer titration) is preferred. 
f) Inorganic impurities: The need for inclusion of tests and acceptance criteria for inorganic 
impurities (e.g., catalysts) should be studied during development and based on knowledge of 
the manufacturing process.  Procedures and acceptance criteria for sulfated ash / residue on 
ignition should follow pharmacopoeial precedents; other inorganic impurities may be 
determined by other appropriate procedures, e.g., atomic absorption spectroscopy. 
g) Microbial limits: There may be a need to specify the total count of aerobic 
microorganisms, the total count of yeasts and molds, and the absence of specific objectionable 
 
© EMEA 2006 
 
12 
bacteria (e.g., Staphylococcus aureus, Escherichia coli, Salmonella, Pseudomonas 
aeruginosa). These should be suitably determined using pharmacopoeial procedures.  The 
type of microbial test(s) and acceptance criteria should be based on the nature of the drug 
substance, method of manufacture, and the intended use of the drug product.  For example, 
sterility testing may be appropriate for drug substances manufactured as sterile and endotoxin 
testing may be appropriate for drug substances used to formulate an injectable drug product.  
Decision tree #6 provides additional guidance on when microbial limits should be included. 
3.3.2. New drug products 
Additional tests and acceptance criteria generally should be included for particular new drug 
products. The following selection presents a representative sample of both the drug products 
and the types of tests and acceptance criteria which may be appropriate. The specific dosage 
forms addressed include solid oral drug products, liquid oral drug products, and parenterals 
(small and large volume). Application of the concepts in this guideline to other dosage forms 
is encouraged. Note that issues related to optically active drug substances and to solid state 
considerations for drug products are discussed in part 3.3.1. of this guideline.  
3.3.2.1 The following tests are applicable to tablets (coated and uncoated) and hard capsules. 
One or more of these tests may also be applicable to soft capsules and granules. 
a) Dissolution: The specification for solid oral dosage forms normally includes a test to 
measure release of drug substance from the drug product.  Single-point measurements are 
normally considered to be suitable for immediate-release dosage forms. For modified-release 
dosage forms, appropriate test conditions and sampling procedures should be established. For 
example, multiple time point sampling should be performed for extended-release dosage 
forms, and two-stage testing (using different media in succession or in parallel, as 
appropriate) may be appropriate for delayed-release dosage forms. In these cases it is 
important to consider the populations of individuals who will be taking the drug product (e.g., 
achlorhydric elderly) when designing the tests and acceptance criteria.  In some cases (see 
3.3.2.1 b) Disintegration) dissolution testing may be replaced by disintegration testing  (see 
Decision Tree #7 (1)). 
For immediate-release drug products where changes in dissolution rate have been 
demonstrated to significantly affect bioavailability, it is desirable to develop test conditions 
which can distinguish batches with unacceptable bioavailability.  If changes in formulation or 
process variables significantly affect dissolution and such changes are not controlled by 
another aspect of the specification, it may also be appropriate to adopt dissolution test 
conditions which can distinguish these changes  (see Decision Tree #7(2)).  
Where dissolution significantly affects bioavailability, the acceptance criteria should be set to 
reject batches with unacceptable bioavailability.  Otherwise, test conditions and acceptance 
criteria should be established which pass clinically acceptable batches  (see Decision Tree 
#7(2)). 
For extended-release drug products, in vitro / in vivo correlation may be used to establish 
acceptance criteria when human bioavailability data are available for formulations exhibiting 
different release rates. Where such data are not available, and drug release cannot be shown to 
be independent of in vitro test conditions, then acceptance criteria should be established on 
the basis of available batch data. Normally, the permitted variability in mean release rate at 
any given time point should not exceed a total numerical difference of +/-10% of the labeled 
content of drug substance (i.e., a total variability of 20%: a requirement of 50 +/- 10% thus 
means an acceptable range from 40% to 60%), unless a wider range is supported by a 
bioequivalency study  (see Decision Tree #7(3)). 
 
© EMEA 2006 
 
13 
b) Disintegration: For rapidly dissolving (dissolution >80% in 15 minutes at pH 1.2, 4.0 and 
6.8) products containing drugs which are highly soluble throughout the physiological range 
(dose/solubility volume < 250 mL from pH 1.2 to 6.8), disintegration may be substituted for 
dissolution.  Disintegration testing is most appropriate when a relationship to dissolution has 
been established or when disintegration is shown to be more discriminating than dissolution. 
In such cases dissolution testing may not be necessary. It is expected that development 
information will be provided to support the robustness of the formulation and manufacturing 
process with respect to the selection of dissolution vs. disintegration testing  (see Decision 
Tree #7(1)). 
c) Hardness/friability: It is normally appropriate to perform hardness and/or friability testing 
as an in-process control (see section 2.3). Under these circumstances, it is normally not 
necessary to include these attributes in the specification. If the characteristics of hardness and 
friability have a critical impact on drug product quality (e.g., chewable tablets), acceptance 
criteria should be included in the specification.  
d) Uniformity of dosage units: This term includes both the mass of the dosage form and the 
content of the active substance in the dosage form; a pharmacopoeial procedure should be 
used. In general, the specification should include one or the other but not both.  If appropriate, 
these tests may be performed in-process; the acceptance criteria should be included in the 
specification.  When weight variation is applied for new drug products exceeding the 
threshold value to allow testing uniformity by weight variation, applicants should verify 
during drug development that the homogeneity of the product is adequate. 
e) Water content: A test for water content should be included when appropriate. The 
acceptance criteria may be justified with data on the effects of hydration or water absorption 
on the drug product. In some cases, a Loss on Drying procedure may be considered adequate; 
however, a detection procedure which is specific for water (e.g., Karl Fischer titration) is 
preferred. 
f) Microbial limits: Microbial limit testing is seen as an attribute of Good Manufacturing 
Practice, as well as of quality assurance. In general, it is advisable to test the drug product 
unless its components are tested before manufacture and the manufacturing process is known, 
through validation studies, not to carry a significant risk of microbial contamination or 
proliferation.  It should be noted that, whereas this guideline does not directly address 
excipients, the principles discussed here may be applicable to excipients as well as to new 
drug products. Skip testing may be an appropriate approach in both cases where permissible.  
(See Decision Tree #6 for microbial testing of excipients.) 
Acceptance criteria should be set for the total count of aerobic microorganisms, the total count 
of yeasts and moulds, and the absence of specific objectionable bacteria (e.g. Staphylococcus 
aureus, Escherichia coli, Salmonella, Pseudomonas aeruginosa). These should be determined 
by suitable procedures, using pharmacopoeial procedures, and at a sampling frequency or 
time point in manufacture which is justified by data and experience.  The type of microbial 
test(s) and acceptance criteria should be based on the nature of the drug substance, method of 
manufacture, and the intended use of the drug product. With acceptable scientific justification, 
it should be possible to propose no microbial limit testing for solid oral dosage forms.  
Decision tree #8 provides additional guidance on the use of microbial limits testing.    
3.3.2.2 Oral liquids: One or more of the following specific tests will normally be applicable 
to oral liquids and to powders intended for reconstitution as oral liquids. 
a) Uniformity of dosage units: This term includes both the mass of the dosage form and the 
content of the active substance in the dosage form; a pharmacopoeial procedure should be 
used. In general, the specification should include one or the other but not both.  When weight 
variation is applied for new drug products exceeding the threshold value to allow testing 
 
© EMEA 2006 
 
14 
uniformity by weight variation, applicants should verify during drug development that the 
homogeneity of the product is adequate. 
If appropriate, tests may be performed in-process; however, the acceptance criteria should be 
included in the specification. This concept may be applied to both single-dose and multiple-
dose packages. 
The dosage unit is considered to be the typical dose taken by the patient. If the actual unit 
dose, as taken by the patient, is controlled, it may either be measured directly or calculated, 
based on the total measured weight or volume of drug divided by the total number of doses 
expected. If dispensing equipment (such as medicine droppers or dropper tips for bottles) is an 
integral part of the packaging, this equipment should be used to measure the dose. Otherwise, 
a standard volume measure should be used. The dispensing equipment to be used is normally 
determined during development. 
For powders for reconstitution, uniformity of mass testing is generally considered acceptable. 
b) pH: Acceptance criteria for pH should be provided where applicable and the proposed 
range justified. 
c) Microbial limits: Microbial limit testing is seen as an attribute of Good Manufacturing 
Practice, as well as of quality assurance. In general, it is advisable to test the drug product 
unless its components are tested before manufacture and the manufacturing process is known, 
through validation studies, not to carry a significant risk of microbial contamination or 
proliferation.  It should be noted that, whereas this Guideline does not directly address 
excipients, the principles discussed here may be applicable to excipients as well as to new 
drug products.  Skip testing may be an appropriate approach in both cases where permissible.  
With acceptable scientific justification, it may be possible to propose no microbial limit 
testing for powders intended for reconstitution as oral liquids.  
Acceptance criteria should be set for the total count of aerobic microorganisms, total count of 
yeasts and molds, and the absence of specific objectionable bacteria (e.g., Staphylococcus 
aureus, Escherichia coli, Salmonella, Pseudomonas aeruginosa). These should be determined 
by suitable procedures, using pharmacopoeial procedures, and at a sampling frequency or 
time point in manufacture which is justified by data and experience.  
Decision tree #8 provides additional guidance on the use of microbial limits testing. 
d) Antimicrobial preservative content: For oral liquids needing an antimicrobial preservative, 
acceptance criteria for preservative content should be established.  Acceptance criteria for 
preservative content should be based upon the levels of antimicrobial preservative necessary 
to maintain microbiological quality of the product at all stages throughout its proposed usage 
and shelf-life. The lowest specified concentration of antimicrobial preservative should be 
demonstrated to be effective in controlling microorganisms by using a pharmacopoeial 
antimicrobial preservative effectiveness test.  
Testing for antimicrobial preservative content should normally be performed at release. 
Testing for antimicrobial preservative content should normally be performed at release.  
Under certain circumstances, in-process testing may suffice in lieu of release testing. When 
antimicrobial preservative content testing is performed as an in-process test, the acceptance 
criteria should remain part of the specification.  
Antimicrobial preservative effectiveness should be demonstrated during development, during 
scaleup, and throughout the shelf-life (e.g., in stability testing: see the ICH Guideline, 
“Stability Testing of New Drug Substances and Products”), although chemical testing for 
preservative content is the attribute normally included in the specification. 
e) Antioxidant preservative content: Release testing for antioxidant content should normally 
be performed. Under certain circumstances, where justified by developmental and stability 
 
© EMEA 2006 
 
15 
data, shelf-life testing may be unnecessary, and in-process testing may suffice in lieu of 
release testing where permitted.  When antioxidant content testing is performed as an in-
process test, the acceptance criteria should remain part of the specification. If only release 
testing is performed, this decision should be reinvestigated whenever either the manufacturing 
procedure or the container/closure system changes. 
f) Extractables: Generally, where development and stability data show evidence that 
extractables from the container/closure systems are consistently below levels that are 
demonstrated to be acceptable and safe, elimination of this test can normally be accepted.  
This should be reinvestigated if the container/closure system or formulation changes. 
Where data demonstrate the need, tests and acceptance criteria for extractables from the 
container/closure system components (e.g., rubber stopper, cap liner, plastic bottle, etc.) are 
considered appropriate for oral solutions packaged in non-glass systems, or in glass containers 
with non-glass closures. The container/closure components should be listed, and data 
collected for these components as early in the development process as possible. 
g) Alcohol content: Where it is declared quantitatively on the label in accordance with 
pertinent regulations, the alcohol content should be specified. It may be assayed or calculated. 
h) Dissolution: In addition to the attributes recommended immediately above, it may be 
appropriate (e.g., insoluble drug substance) to include dissolution testing and acceptance 
criteria for oral suspensions and dry powder products for resuspension.  Dissolution testing 
should be performed at release. This test may be performed as an in-process test when 
justified by product development data. The testing apparatus, media, and conditions should be 
pharmacopoeial, if possible, or otherwise justified. Dissolution procedures using either 
pharmacopoeial or non-pharmacopoeial apparatus and conditions should be validated.  
Single-point measurements are normally considered suitable for immediate-release dosage 
forms. Multiple-point sampling, at appropriate intervals, should be performed for modified-
release dosage forms. Acceptance criteria should be set based on the observed range of 
variation, and should take into account the dissolution profiles of the batches that showed 
acceptable performance in vivo. Developmental data should be considered when determining 
the need for either a dissolution procedure or a particle size distribution procedure.  
i) Particle size distribution: Quantitative acceptance criteria and a procedure for 
determination of particle size distribution may be appropriate for oral suspensions. 
Developmental data should be considered when determining the need for either a dissolution 
procedure or a particle size distribution procedure for these formulations.  
Particle size distribution testing should be performed at release.  It may be performed as an in-
process test when justified by product development data. If these products have been 
demonstrated during development to have consistently rapid drug release characteristics, 
exclusion of a particle size distribution test from the specification may be proposed.  
Particle size distribution testing may also be proposed in place of dissolution testing; 
justification should be provided. The acceptance criteria should include acceptable particle 
size distribution in terms of the percent of total particles in given size ranges. The mean, 
upper, and / or lower particle size limits should be well defined.  
Acceptance criteria should be set based on the observed range of variation, and should take 
into account the dissolution profiles of the batches that showed acceptable performance in 
vivo, as well as the intended use of the product. The potential for particle growth should be 
investigated during product development; the acceptance criteria should take the results of 
these studies into account.  
 
© EMEA 2006 
 
16 
j) Redispersibility: For oral suspensions which settle on storage (produce sediment), 
acceptance criteria for redispersibility may be appropriate. Shaking may be an appropriate 
procedure.   
The procedure (mechanical or manual) should be indicated. Time required to achieve 
resuspension by the indicated procedure should be clearly defined. Data generated during 
product development may be sufficient to justify skip lot testing, or elimination of this 
attribute from the specification may be proposed. 
k) Rheological properties: For relatively viscous solutions or suspensions, it may be 
appropriate to include rheological properties (viscosity/specific gravity) in the specification. 
The test and acceptance criteria should be stated. Data generated during product development 
may be sufficient to justify skip lot testing, or elimination of this attribute from the 
specification may be proposed. 
l)  Reconstitution time: Acceptance criteria for reconstitution time should be provided for dry 
powder products which require reconstitution. The choice of diluent should be justified. Data 
generated during product development may be sufficient to justify skip lot testing or 
elimination of this attribute from the specification may be proposed. 
m) Water content: For oral products requiring reconstitution, a test and acceptance criterion 
for water content should be proposed when appropriate. Loss on drying is generally 
considered sufficient if the effect of absorbed moisture vs. water of hydration has been 
adequately characterized during the development of the product. In certain cases a more 
specific procedure (e.g., Karl Fischer titration) may be preferable. 
3.3.2.3 Parenteral Drug Products: The following tests may be applicable to parenteral drug 
products. 
a) Uniformity of dosage units: This term includes both the mass of the dosage form and the 
content of the active substance in the dosage form; a pharmacopoeial procedure should be 
used.  In general, the specification should one or the other but not both and is applicable to 
powders for reconstitution.   When weight variation is applied for new drug products 
exceeding the threshold value to allow testing uniformity by weight variation, applicants 
should verify during drug development that the homogeneity of the product is adequate. 
If appropriate (see section 2.3), these tests may be performed in-process; the acceptance 
criteria should be included in the specification. This test may be applied to both single-dose 
and multiple-dose packages. 
For powders for reconstitution, uniformity of mass testing is generally considered acceptable. 
b) pH: Acceptance criteria for pH should be provided where applicable and the proposed 
range justified. 
c) Sterility: All parenteral products should have a test procedure and acceptance criterion for 
evaluation of sterility. Where data generated during development and validation justify 
parametric release, this approach may be proposed for terminally sterilized drug products (see 
section 2.6).  
d) Endotoxins/Pyrogens: A test procedure and acceptance criterion for endotoxins, using a 
procedure such as the limulus amoebocyte lysate test, should be included in the specification.  
Pyrogenicity testing may be proposed as an alternative to endotoxin testing where justified. 
e) Particulate matter: Parenteral products should have appropriate acceptance criteria for 
particulate matter. This will normally include acceptance criteria for visible particulates and / 
or clarity of solution, as well as for sub-visible particulates as appropriate.  
f) Water content: For non-aqueous parenterals, and for parenteral products for reconstitution, 
a test procedure and acceptance criterion for water content should be proposed when 
 
© EMEA 2006 
 
17 
appropriate. Loss on drying is generally considered sufficient for parenteral products, if the 
effect of absorbed moisture vs. water of hydration has been adequately characterized during 
development. In certain cases a more specific procedure (e.g., Karl Fischer titration) may be 
preferred. 
g) Antimicrobial preservative content: For parenteral products needing an antimicrobial 
preservative, acceptance criteria for preservative content should be established. Acceptance 
criteria for preservative content should be based upon the levels of antimicrobial preservative 
necessary to maintain microbiological quality of the product at all stages throughout its 
proposed usage and shelf life. The lowest specified concentration of antimicrobial 
preservative should be demonstrated to be effective in controlling microorganisms by using a 
pharmacopoeial antimicrobial preservative effectiveness test.   
Testing for antimicrobial preservative content should normally be performed at release.  
Under certain circumstances, in-process testing may suffice in lieu of release testing where 
permitted.  When antimicrobial preservative content testing is performed as an in-process test, 
the acceptance criteria should remain part of the specification.  
Antimicrobial preservative effectiveness should be demonstrated during development, during 
scaleup, and throughout the shelf-life (e.g., in stability testing: see the ICH Guideline, 
“Stability Testing of New Drug Substances and Products”), although chemical testing for 
preservative content is the attribute normally included in the specification. 
h) Antioxidant preservative content: Release testing for antioxidant content should normally 
be performed. Under certain circumstances, where justified by developmental and stability 
data, shelf-life testing may be unnecessary and in-process testing may suffice in lieu of release 
testing. When antioxidant content testing is performed as an in-process test, the acceptance 
criteria should remain part of the specification. If only release testing is performed, this 
decision should be reinvestigated whenever either the manufacturing procedure or the 
container/closure system changes. 
i) Extractables: Control of extractables from container/closure systems is considered 
significantly more important for parenteral products than for oral liquids. However, where 
development and stability data show evidence that extractables are consistently below the 
levels that are demonstrated to be acceptable and safe, elimination of this test can normally be 
accepted. This should be reinvestigated if the container/closure system or formulation 
changes. 
Where data demonstrate the need, acceptance criteria for extractables from the 
container/closure components are considered appropriate for parenteral products packaged in 
non-glass systems or in glass containers with elastomeric closures. This testing may be 
performed at release only, where justified by data obtained during development. The 
container/closure system components (e.g., rubber stopper, etc.) should be listed, and data 
collected for these components as early in the development process as possible. 
j) Functionality testing of delivery systems: Parenteral formulations packaged in pre-filled 
syringes, autoinjector cartridges, or the equivalent should have test procedures and acceptance 
criteria related to the functionality of the delivery system. These may include control of 
syringeability, pressure, and seal integrity (leakage), and/or parameters such as tip cap 
removal force, piston release force, piston travel force, and power injector function force.  
Under certain circumstances these tests may be performed in-process. Data generated during 
product development may be sufficient to justify skip lot testing or elimination of some or all 
attributes from the specification.  
k) Osmolarity: When the tonicity of a product is declared in its labeling, appropriate control 
of its osmolarity should be performed. Data generated during development and validation may 
 
© EMEA 2006 
 
18 
be sufficient to justify performance of this procedure as an in-process control, skip lot testing, 
or direct calculation of this attribute. 
l) Particle size distribution: Quantitative acceptance criteria and a procedure for 
determination of particle size distribution may be appropriate for injectable suspensions. 
Developmental data should be considered when determining the need for either a dissolution 
procedure or a particle size distribution procedure.  
Particle size distribution testing should be performed at release.  It may be performed as an in-
process test when justified by product development data.  If the product has been 
demonstrated during development to have consistently rapid drug release characteristics, 
exclusion of particle size controls from the specification may be proposed.  
Particle size distribution testing may also be proposed in place of dissolution testing, when 
development studies demonstrate that particle size is the primary factor influencing 
dissolution; justification should be provided. The acceptance criteria should include 
acceptable particle size distribution in terms of the percent of total particles in given size 
ranges. The mean, upper, and / or lower particle size limits should be well defined.  
Acceptance criteria should be set based on the observed range of variation, and should take 
into account the dissolution profiles of the batches that showed acceptable performance in 
vivo and the intended use of the product. The potential for particle growth should be 
investigated during product development; the acceptance criteria should take the results of 
these studies into account. 
m) Redispersibility: For injectable suspensions which settle on storage (produce sediment), 
acceptance criteria for redispersibility may be appropriate. Shaking may be an appropriate 
procedure.  The procedure (mechanical or manual) should be indicated.  Time required to 
achieve resuspension by the indicated procedure should be clearly defined.  Data generated 
during product development may be sufficient to justify skip lot testing, or elimination of this 
attribute from the specification may be proposed. 
n) Reconstitution time: Acceptance criteria for reconstitution time should be provided for all 
parenteral products which require reconstitution.  The choice of diluent should be justified.  
Data generated during product development and process validation may be sufficient to 
justify skip lot testing or elimination of this attribute from the specification for rapidly 
dissolving products. 
 
© EMEA 2006 
 
19 
4.  
GLOSSARY (THE FOLLOWING DEFINITIONS ARE PRESENTED FOR THE 
PURPOSE OF THIS GUIDELINE)   
Acceptance criteria: Numerical limits, ranges, or other suitable measures for acceptance of 
the results of analytical procedures. 
Chiral: Not superimposable with its mirror image, as applied to molecules, conformations, 
and macroscopic objects, such as crystals. the term has been extended to samples of 
substances whose molecules are chiral, even if the macroscopic assembly of such molecules is 
racemic. 
Combination product: A drug product which contains more than one drug substance. 
Degradation product: A molecule resulting from a chemical change in the drug molecule 
brought about over time and/or by the action of e.g., light, temperature, pH, water, or by 
reaction with an excipient and/or the immediate container/closure system. Also called 
decomposition product. 
Delayed Release: Release of a drug (or drugs) at a time other than immediately following oral 
administration.   
Enantiomers: Compounds with the same molecular formula as the drug substance, which 
differ in the spatial arrangement of atoms within the molecule and are nonsuperimposable 
mirror images. 
Extended Release: Products which are formulated to make the drug available over an 
extended period after administration. 
Highly Water Soluble Drugs: Drugs with a dose/solubility volume of less than or equal to 
250 ml over a pH  range of  1.2 to 6.8. (Example: Compound A has as its lowest solubility at 
37± 0.5°C, 1.0 mg/ml at pH 6.8, and is available in 100 mg, 200 mg, and 400 mg strengths.  
This drug would be considered a low solubility drug as its dose/solubility volume is greater 
than 250 mL (400 mg/1.0 mg/ml = 400 ml). 
Immediate Release: Allows the drug to dissolve in the gastrointestinal contents, with no 
intention of delaying or prolonging the dissolution or absorption of the drug. 
Impurity: (1) Any component of the new drug substance which is not the chemical entity 
defined as the new drug substance. (2) Any component of the drug product  which is not the 
chemical entity defined as the drug substance or an excipient in the drug product. 
Identified impurity: An impurity for which a structural characterization has been achieved. 
In-process tests: Tests which may be performed during the manufacture of either the drug 
substance or drug product, rather than as part of the formal battery of tests which are 
conducted prior to release. 
Modified Release: Dosage forms whose drug-release characteristics of time course and/or 
location are chosen to accomplish therapeutic or convenience objectives not offered by 
conventional dosage forms such as a solution or an immediate release dosage form. Modified 
release solid oral dosage forms include both delayed and extended release drug products. 
New drug product: A pharmaceutical product type, for example, tablet, capsule, solution, 
cream, etc.,  which has not previously been registered in a region or Member State, and which 
contains a drug ingredient generally, but not necessarily, in association with excipients. 
New drug substance: The designated therapeutic moiety, which has not previously been 
registered in a region or Member State (also referred to as a new molecular entity or new 
chemical entity). It may be a complex, simple ester, or salt of a previously approved drug 
substance. 
 
© EMEA 2006 
 
20 
Polymorphism: The occurrence of different crystalline forms of the same drug substance. 
This may include solvation or hydration products (also known as pseudopolymorphs) and 
amorphous forms.  
Quality: The suitability of either a drug substance or drug product for its intended use. This 
term includes such attributes as the identity, strength, and purity. 
Racemate: A composite (solid, liquid, gaseous, or in solution) of equimolar quantities of two 
enantiomeric species. It is devoid of optical activity. 
Rapidly Dissolving Products: An immediate release solid oral drug product is considered 
rapidly dissolving when not less than 80% of the label amount of the drug substance dissolves 
within 15 minutes in each of the following media: (1) pH 1.2, (2) pH 4.0, and (3) pH 6.8.  
Reagent: A substance, other than a starting material or solvent, which is used in the 
manufacture of a new drug substance. 
Solvent: An inorganic or an organic liquid used as a vehicle for the preparation of solutions or 
suspensions in the synthesis of a new drug substance or the manufacture of a new drug 
product. 
Specification: A list of tests, references to analytical procedures, and appropriate acceptance 
criteria which are numerical limits, ranges, or other criteria for the tests described. It 
establishes the set of criteria to which a drug substance or drug product should conform to be 
considered acceptable for its intended use. "Conformance to specifications" means that the 
drug substance and / or drug product, when tested according to the listed analytical 
procedures, will meet the listed acceptance criteria. Specifications are critical quality 
standards that are proposed and justified by the manufacturer and approved by regulatory 
authorities. 
Specific test: A test which is considered to be applicable to particular new drug substances or 
particular new drug products depending on their specific properties and/or intended use. 
Specified impurity: An identified or unidentified impurity that is selected for inclusion in the 
new drug substance or new drug product specification and is individually listed and limited in 
order to assure the quality of the new drug substance or new drug product. 
Unidentified impurity: An impurity which is defined solely by qualitative analytical 
properties, (e.g., chromatographic retention time). 
Universal test: A test which is considered to be potentially applicable to all new drug 
substances, or all new drug products; e.g., appearance, identification, assay, and impurity 
tests. 
 
© EMEA 2006 
 
21 
5. 
REFERENCES 
International Conference on Harmonization; "Impurities in New Drug Substances", 1995. 
International Conference on Harmonization; "Impurities in New Drug Products", 1996. 
International Conference on Harmonization; "Stability Testing of New Drug Substances and 
Products", 1994. 
International Conference on Harmonization; "Text on Validation of Analytical Procedures", 
1994. 
International Conference on Harmonization; "Validation of Analytical Procedures: 
Methodology", 1996. 
International Conference on Harmonization, "Residual Solvents in Pharmaceuticals", 1996. 
International Conference on Harmonization, “Specifications: Test Procedures and Acceptance 
Criteria for Biotechnological/Biological Products”, 1999 
6.  
ATTACHMENTS: DECISION TREES #1 THROUGH #8 
For the decision trees referenced in this guideline, see the following pages. 
 
 
© EMEA 2006 
 
22 
 
 
 
© EMEA 2006 
 
23 
 
 
© EMEA 2006 
 
24 
 
 
© EMEA 2006 
 
25 
 
 
© EMEA 2006 
 
26 
 
 
 
 
© EMEA 2006 
 
27 
 
 
© EMEA 2006 
 
28 
 
 
© EMEA 2006 
 
29 
 
 
 
© EMEA 2006 
 
30 
 
 
 
© EMEA 2006 
 
31 
 
 
 
© EMEA 2006 
 
32 
 
 
