REPLACEMENT OF CHLOROFLUOROCARBONS
(CFC) IN METERED DOSE INHALATION PRODUCTS
Guideline Title
Replacement of Chlorofluorocarbons (CFCs) in Metered Dose
Inhalation Products
Legislative basis
Council Regulation No 594/91 as amended, Directive
75/318/EEC as amended
Date of first adoption
December 1993
Date of entry into force
December 1993
Status
Last revised 1993
Previous titles/other
references
None/ III/5378/93
Additional Notes
This guideline is intended to facilitate companies in
compiling the dossier for submission for the replacement of a
CFC propellant in an already authorised medicinal product.
It identifies the considerations of quality, safety and efficacy
which should be taken into account. The need for this
guideline has been accentuated by the imminent lack of
availability of existing replacements for CFC propellants for
these important medicinal products.
CONTENTS
1.
INTRODUCTION
2.
PHARMACEUTICAL REQUIREMENTS
3.
PRECLINICAL REQUIREMENTS
4.
CLINICAL REQUIREMENTS FOR INHALATION PRODUCTS
155
_________________________________________________________________ 3BR3a  I
REPLACEMENT OF CHLOROFLUOROCARBONS
(CFC) IN METERED DOSE INHALATION PRODUCTS
1.
INTRODUCTION
Chlorofluorocarbon (CFC) propellants are currently under discussion because of their deleterious
effect on the ozone layer. CFCs and halons have a high resistance to biotic and abiotic
decomposition and pass into the atmosphere undecomposed, and slowly ascend to the
stratosphere. Current scientific knowledge on the possible destruction of the ozone layer, and the
harmful effects that can thereby be anticipated, has been presented at recent international
conferences.
There is an international consensus that significant reductions are necessary in both the
production and the consumption of substances which deplete the ozone layer. Thus all member
states and the Community have become parties to the Vienna convention for the protection of the
ozone layer and the Montreal protocol on substances that deplete the ozone layer.
Council Regulation (EEC) No 594/91 as amended by Council Regulation (EEC) No 395/92 of 29
December 1992 prescribes a schedule for the phasing-out of substances that deplete the ozone
layer. This includes schedules for the limitation and prohibition of the importation, exportation,
production, and supply of chlorofluorocarbons and products containing them.
Many pharmaceutical products on the market contain CFCs as propellants and, in accordance
with the regulations, companies will be reformulating their products to replace the CFC
propellants with a suitable alternative. In the event that the replacement contains a new
propellant (excipient) not previously authorised, the provisions of Directive 75/318/EEC as
amended, apply.
This guideline has been prepared to facilitate companies in compiling the dossier for submission
for the replacement of a CFC propellant in an already authorised medicinal product, and
identifies the considerations of quality, safety and efficacy which should be taken into account.
The need for this guideline has been accentuated by the imminent lack of availability of existing
replacements for CFC propellants for these important medicinal products. It mainly addresses
MDIs for the management of asthma and other chronic obstructive airway diseases. However, in
principle it could be followed for inhalation products used for other therapeutic indications.
Appropriate expert reports should be submitted in support of the marketing authorisation, using
the format given in the Notice to Applicants. At the request of the company the assessment of the
product could be co-ordinated between member states.
Data are required to show that the new and the old products are at least therapeutically
equivalent.
156
I  3BR3a _________________________________________________________________
2.
PHARMACEUTICAL REQUIREMENTS
2.1 New Propellant Specification
Documentation should be provided for the new propellant(s) taking as a basis the note for
guidance on Chemistry of Active Substances. A suitable specification should be developed based
on the quality of batches used in the toxicological tests.
2.2 Container and valves
Information should be provided if new containers and/or valves are used for the new formulated
product.
2.3 Active substance
It is expected that the same active substance specification will be applied, particularly with
regard to particle size specification. Any changes required because of reformulation should be
justified and fully discussed in the pharmaceutical expert report.
Changes in the state of solvation (or desolvation) of the active substance should be investigated
and the physical-chemical problems which arise if such a change is observed (e.g. crystal growth
on storage) should be addressed.
2.4 Finished Product
The points listed below are not a comprehensive list of items to be addressed or specifications to
be included. They include those issues which should be addressed in all cases and on which
guidance may be required. This information should be given according to Part II A4
(Pharmaceutical development) and should be included in the stability protocol as outlined below.
Sufficient canisters should be tested to give confidence in the results.
The following investigations on the finished product are intended to ensure whether the
specifications of the already authorised product have to be changed or not. Any changes should be
justified.
2.4.1 Moisture Content
The moisture content of the formulation should be evaluated and if necessary controlled because
of its possible effect on stability and spray pattern.
2.4.2 Extractables
Data should be provided by the applicant demonstrating the extent of extraction of components
into the formulation from the valve and container, monitored at least as long as the extraction
reaches an equilibrium.
Information should also be provided on any processes used for the pre-extraction of materials
from valve components prior to use. Such processes should be shown to produce the required end
product consistently.
157
_________________________________________________________________ 3BR3a  I
2.4.3 Priming Shots
The need for priming shots should be addressed: .
–
before first use of the canisters
–
after a time period typically allowed to elapse between doses as stated in the labelling
–
after an extended period of non-use (3-5 days).
2.4.4 Amount Delivered
The amount of active substance delivered from the valves should be determined using the BP test
for “content of active substance”. This should be evaluated at the start (excluding priming shots if
necessary) and at the end of the nominal (labelled) number of shots in the can.
2.4.5 Uniformity of Content
The uniformity of content per actuation ex valve or ex actuator should be reported and must be
based on the assay of individual shots. If the canister contains a solution, the uniformity test can
be performed as a weight determination of individual shots. The delivery should be assessed at
the start and at the end of the nominal number of shots in the can.
The uniformity should also be assessed from the last nominal shot to exhaustion of the canister.
The following test is considered suitable:
Select 10 canisters from each of the valve up and down orientations of storage. Assay one shot
from the start (excluding priming shot if necessary) and the end of the nominal (labelled) number
of shots of each of the 10 containers.
The content of active of each shot should be < ± 25% of the mean.
If not more than 6 of 40 contents are > ± 25% of the mean but not more than ± 35%, test a further
10 canisters from each of the valve up and the valve down orientations.
Not more than 6 of 80 contents should be >+ 25% of the mean but not more than 35%.
The mean content of the shots as determined in this test should be within + 10% of the labelled
claim.
2.4.6 Deposition of the emitted dose
The particle size distribution of the active substance in the aerosol should be evaluated by the
determination of the deposition of the emitted dose using samples from the start and end of
nominal shot content and to the point of exhaustion of the container.
Data from a multistage impinger is preferred showing calculation of respirable fraction,
aerodynamic mass median diameter and geometric standard deviation. Additional data from the
deposition of active substance using the twin impinger apparatus (B.P. App. XVII C Apparatus A)
should be provided.
The amount retained by the actuator/mouthpiece should be evaluated. From the; data provided, it
should be possible to draw up a mass balance sheet of the active substance. The use of other
methods should be justified.
The finished product specification should contain suitable limits of the derived parameters based
on the batch used in in-vivo trials.
158
I  3BR3a _________________________________________________________________
Significant changes in these parameters over the shelf life of the product may need to be
supported by in-vivo bioequivalence data.
2.4.7 Stability
Sufficient real-time data should be provided to assess product stability over the shelf life of the
product. Data from at least two batches should be reported. In designing stability trials, the
product should be stored in the valve-up and the valve-down orientations of storage at fixed
conditions of temperature and humidity and cycling conditions. Data should be presented
separately for both orientations.
The following information is required as discussed below:
–
all items mentioned under 2.4.1-2.4.6. Data from each test need not be presented at each
testing point but sufficient data should be generated in the protocol to give confidence in
the stability of the product.
–
information of content of active substance and decomposition products.
The characteristics of the formulation, the inner surface of the container and the leaching should
be evaluated. Also the leakage of the contents from the container should be determined. If
necessary suitable specifications should be established.
3.
PRECLINICAL REQUIREMENTS
The safety of any new propellant shall have been suitably demonstrated as required by Directive
75/318/EEC as amended, where it refers to the development of new excipients.
The safety studies should have been carried out on batches of the excipient (propellant) that
contained the impurities listed in the specification and at dose levels that allowed greater
exposure of the test animals to these impurities than will occur in patients.
The contribution of animal model testing to the safety assessment of any individual active
substance will be known from previous formulations. There thus remains the need to consider
what preclinical studies could be appropriate to “bridge” the gap of knowledge between the
databases for existing products and the potential new products containing a propellant plus other
excipients.
In cases in which sufficient human safety data are available, preclinical studies may not be
necessary.
Two aspects of safety are considered in this guideline - local effects and any possible systemic
action that could differ from known data. The type of information required to give reassurance on
safety and that can be usefully generated in animal models, is indicated. The design of studies to
achieve this information may vary to accommodate the needs of individual active substances and
formulations.
3.1 Local effects
It is possible that combining a known active substance with a new propellant system could
produce interactions that result in an irritant or potentially hazardous formulation when applied
to the respiratory system. Because a proportion of a dose intended for inhalation will also enter
159
_________________________________________________________________ 3BR3a  I
the upper gastrointestinal tract, any new formulations should also be appropriately safe for
ingestion. Separate oral studies will normally not be necessary.
Animal models may be useful to determine irritation effects or other undesirable consequences
such as local retention resulting from inappropriate deposition characteristics. Data to reassure
that these effects are unlikely in man could come from inhalation studies in an appropriate
animal species. The design of such studies should allow examination of the local tissues involved
to demonstrate the absence of significant treatment-related effects of the type described above
resulting from inhalation and ingestion.
3.2 Systemic Activity
The testing of new inhalation products in clinical trials should have produced data on the relative
absorption of the active substance in comparison with existing authorised products. The kinetic
parameter values from plasma or other suitable assays, performed to show comparative systemic
exposure, can be used to determine whether the existing safety margins are likely to be eroded. If
not, then further animal studies would not be necessary. If so, the resulting safety factor may be
reassessed on the basis of existing toxicological data to demonstrate, if possible, that an adequate
margin remains. If the exposure has increased to such an extent that the validity of the
pharmacology and toxicology (long term – repeated dose and effects on reproduction) has
disappeared, it may be necessary to perform further animal studies to re-establish an appropriate
reassurance.
3.3 Other Studies
At this time it is not envisaged that testing for mutagenic or carcinogenic potential for a
combination of active substances and novel propellant excipients will be required, when each
individual component in isolation has been shown not to have these potential effects.
Similarly, single dose studies and pharmacodynamic studies in animals are not considered to be
necessary, except where they form a part of the testing for local adverse reactions or may be
appropriate to test systemic effects.
Toxicokinetic data may be required to support additional toxicity studies.
4.
CLINICAL REQUIREMENTS FOR INHALATION PRODUCTS
The major clinical requirement to be fulfilled is the need to ensure efficacy and safety of the
reformulated product and to demonstrate that the change in formulation (e.g. due to change in
excipients) has no adverse effect on the benefit-risk ratio to the patients in comparison with the
existing CFC-containing products. Demonstration of pharmaceutical equivalence does not remove
the need for demonstration of at least therapeutic equivalence.
For new non-CFC-containing products demonstrating equivalence with regard to efficacy can be
done in the usual way, taking into account certain statistical considerations (see statistical
consideration – 4.1.1). Depending on the active substance, most experience comes from clinical or
pharmacodynamic trials. Appropriate examples will be considered in the next sections.
Clinical studies will be expected to establish safety in patients. For efficacy, however, in certain
circumstances other studies or models may be appropriate, e.g. pharmacodynamic models,
160
I  3BR3a _________________________________________________________________
pharmacokinetic studies, in vivo and/or in vitro deposition studies. These alternatives should be
clinically validated.
With regard to safety, the usual issues which arise when an inhalation product is reformulated
have to be addressed. In cases where a new unknown excipient is used, specific safety
requirements should also be fulfilled. Data on the absorption, distribution, and retention of the
new propellant in man following inhalation would be valuable in assessing the likely systemic
burden of the propellant.
4.1 Efficacy of the new non-CFC-containing products
The CFC-containing products used in the management of asthma and other chronic obstructive
airway diseases fall into two main classes, those with direct bronchodilator action, the beta2
adrenergic agonists and the anticholinergic agents, and those described as disease modifying
medicinal products, such as glucocorticosteroids (GCS), sodium cromoglycate (SCG) and
nedocromil sodium (NS). The characteristics of these medicinal products and their modes of
action necessitate widely different studies in the assessment of therapeutic equivalence/efficacy.
Any additional claim following reformulation must be fully supported.
For most orally administered medicinal products, therapeutic equivalence is shown by
demonstrating bioequivalence. The measurement of systemic substance levels following
inhalation is not only difficult for some products in the light of the small amounts of substance
reaching the small airways and hence being absorbed and available for pharmacokinetic
comparisons, but its relevance should be questioned when assessing the clinical efficacy of a
substance which is delivered to the lung and where the desired clinical effect is brought about by
local action.
Systemic substance levels are important in relation to safety. However, since a significant portion
of the systemic level may be derived from non-lung deposition, such pharmacokinetic parameters
are less appropriate for determining equivalence than are assessments of efficacy.
For some classes of products the applicant may be able to demonstrate that pharmacokinetic
measures are relevant and appropriate to the assessment of both safety and efficacy (see section
4.1.4).
4.1.1 Statistical Considerations in the Assessment of Therapeutic Equivalence
The aim of a therapeutic equivalence trial is to demonstrate that the test product is of
comparable efficacy to that of a standard therapy. Therapeutic equivalence is often regarded as a
one-sided problem. This is in contrast to bioequivalence trials where it has to be demonstrated
that there is no clinically relevant difference in either direction between the test product and the
standard therapy.
Though the development of new medicinal products which have superior therapeutic effects is
desirable, superiority of the test product to the standard therapy is not usually the primary
concern in therapeutic equivalence trials. Therefore, the statistical analysis should primarily
demonstrate that the test product is not inferior to the standard therapy by a clinically relevant
amount. However, the statistical analysis of a study can in addition be designed to prove the test
product to be superior to the standard therapy, after having confirmed that at least no relevant
inferiority of the test product exists compared to the standard therapy.
161
_________________________________________________________________ 3BR3a  I
Due attention should be given to formulate the null hypothesis and the alternative hypothesis
correctly. Classical hypothesis testing is inappropriate in trials set up to assess therapeutic
equivalence.
The determination of the minimally clinically relevant difference is critical, and should be argued
on an individual basis. The argumentation should take specific clinical considerations into
account. These should include the primary end-point, the statistical model, the indication, the
efficacy of the reference product, and the natural course of the disease.
These considerations will in turn influence the sample size calculations which usually are based
on the primary end-point, the minimally clinically relevant difference, the type I and the type 11
error levels, which all have to be fixed in the study protocol.
Although the arguments above are formulated from the classical (frequentist) viewpoint, the use
of Bayesian or other well-argued approaches is acceptable.
4.1.2 Bronchodilators
For inhaled bronchodilators, demonstration of at least therapeutic equivalence can be obtained
from pharmacodynamic, single dose, short term studies:
e.g. demonstration of equivalent dose and time-dependent increases in pulmonary function
following single inhaled doses in patients with asthma.
It should be demonstrated in the protocol that the dose used in the trial is such that clinically
relevant differences can be shown. Dose-ranging studies will be required if therapeutic
equivalence is not shown.
Appropriate safety monitoring should be carried out, including some measure of systemic effect,
e.g., heart rate, serum potassium and assessment of paradoxical bronchospasm (see also 4.2).
4.1.3 Glucocorticosteroids
The demonstration of clinical bioequivalence of inhaled glucocorticosteroids is difficult and at this
stage in our knowledge the only definitive efficacy studies are the parallel group "head-to-head"
direct clinical comparisons, preferably in steroid-naive patients, with demonstration of clinical
efficacy based on assessments made by the patient at home, recorded on diary cards, and made at
regular, say 2 weekly, intervals in the clinic. Assessments would include pulmonary function
measurements, symptoms scores, inhaled bronchodilator requirements and rate of exacerbations,
defining beforehand an adequate primary outcome-variable. Studies should address a particular
disease severity/dose regimen. The duration of treatment would need to be a minimum period of 4
weeks; longer treatment periods might be advantageous.
Since improvement in patients who are stabilised on corticosteroids is unlikely, the use of such
patients is discouraged. However, if patients on corticosteroids must be entered into a trial, the
pre-entry criteria, the expected improvement and the size and duration of the trial should be
justified.
Single dose allergen challenge studies are artificial compared with natural exposure. There is a
body of evidence which would support the use of the late response as a clinical model for the
evaluation of potential new therapeutic agents, for early dose-ranging in Phase II studies and for
the investigation of basic mechanisms of allergic asthma. However, there is very little
information on the reproducibility or dose-dependency of the late response and therefore its use
in the demonstration of clinical bioequivalence is extremely limited and would not be appropriate.
162
I  3BR3a _________________________________________________________________
Appropriate safety monitoring should be carried out, including some measure of systemic effect,
e.g. assessment of hypothalamic pituitary adrenocortical function and assessment of paradoxical
bronchospasm (see also 4.2).
4.1.4 Sodium Cromoglycate/Nedocromil Sodium
For sodium cromoglycate and nedocromil sodium an assessment of therapeutic equivalence can be
obtained from a single dose pharmacodynamic study looking at the protection afforded against an
exercise challenge or other SCG/NS sensitive challenge (for example cold air, metabisulphite, etc.)
with appropriate justification of the model in respect of clinical efficacy. Such a study would
compare the non-CFC containing product with the CFC-containing product in patients with
known exercise-induced asthma or other induced asthmatic response.
Usual safety monitoring will be included in the study protocol (see 4.2).
4.2 Safety of the new non-CFC-containing Products
The safety profiles of the active substances as currently formulated are not in question. However,
potential safety concerns do arise, both from the use of new excipients, including the new
non-CFC-containing propellants, where safety in man following inhalation has not been
investigated previously, and also from any possible interactions between these new excipients
(including propellants) and the active substances, interactions which might enhance toxicity of
the active substance. We should also be aware that the change in excipients (including
propellants) might result in changes in product deposition patterns within the lung which might
affect absorption and systemic safety.
Full animal toxicology will have been completed for each new excipient (see 3) but such data will
not remove the need for clinical safety studies in man.
The aims of the safety program are twofold:
i)
to determine the safety of a new excipient mix in a formulated medicinal product.
ii)
to assess interactions which may occur between an active substance and an excipient mix
which might result in changes in the safety of the medicinal product.
The safety of a new excipient mix need only be addressed once, but the assessment of interactions
will be required for each substance combined with that new excipient mix (including new
propellants). Obviously if changes in absorption or systemic safety are seen in these interaction
studies, these changes will need to be quantified and long-term safety assessments of the active
product formulated in that excipient mix may be required.
A change in the excipient mix will necessitate long term safety assessment.
4.2.1 Assessment of clinical safety of the new excipients (including propellants)
in the formulated medicinal product
These studies will be large safety studies and are needed primarily to assess the safety of the new
excipients (including the new propellants) in the formulated medicinal product.
Repeated dose comparative prospective studies will be required and the double-blind comparison
has obvious advantages over the open design, resulting in a more definitive safety statement. The
new non-CFC-containing product should be compared with the authorised CFC-containing
product in a controlled randomised study over a treatment period of 3 months prior to marketing.
163
_________________________________________________________________ 3BR3a  I
The trials should be set up in such a way that it is clear that the patients who complete them are
representative of the whole patient population. The study design should be such as to encompass
an assessment of the changeover from the original CFC-containing product to the new
non-CFC-containing product.
Adverse event and haematological and biochemical monitoring should be undertaken in all safety
studies, together with specific assessments, pertinent to the substance, to look for local and
systemic effects which might not necessarily be recorded as, or manifest themselves as, adverse
events. The designs should incorporate assessment of cough, wheezing and bronchospasm
following inhalation and attempt to look at the incidence of this potentially dangerous/life
threatening adverse effect. Proposals should be put forward to monitor the introduction of the
new non CFC products in order to identify rare and unexpected adverse effects. A method such as
the use of record linkage schemes should be considered, as these could provide a means for
prospectively monitoring the new non CFC products against historical data relating to the
products using CFC propellants.
(Careful observation of patients and a specific assessment of cough, wheezing and bronchospasm
on first administration of the product during the first clinic visit, paying particular attention to
the time to onset of any effect, could also be useful. Specific questioning and assessment of
paradoxical bronchospasm would be appropriate in single dose studies and after the first dose of
each limb in crossover studies.)
4.2.2 The assessment of clinical safety following re-formulation to assess any
possible interactions between the substance and the new excipients
These studies will be of shorter duration and will be required for all inhaled products which have
undergone re-formulation as described. These much shorter clinical safety studies are essentially
looking at any possible interactions between the new excipients and the active substance,
interactions which might result in changes in product safety.
Similar safety assessments, as described under 4.2.1 should be made but with specific emphasis
on assessments to pick up acute toxicity, bronchospasm following inhalation and enhanced
systemic activity. Monitoring should be focused on the known adverse event profiles of the
CFC-containing product to assess change in these profiles as a consequence of the use of new
excipients, together with attempting to identify new and unexpected effects.
Detailed safety studies are required; comparative efficacy assessments could be built into the
designs as described in 4.1.3 above and might also include assessments of bronchial reactivity. In
this way, efficacy and (short-term) safety can be assessed in the same study, with assessments
based on clinical endpoints. Such studies might be one month comparative studies (CFC vs.
non-CFC) of appropriate sample size. They would require careful statistical input to ensure
adequate size and power to detect any clinically important differences between treatments in
respect of safety.
4.3 Studies in children
The profile of the non-CFC-containing products following administration to children under 12
years must also be addressed.