EMA/CHMP/CVMP/QWP/850374/2015
Committee for Medicinal Products for Human use (CHMP)
Committee for Medicinal Products for Veterinary use (CVMP)
Guideline on the sterilisation of the medicinal product, 
active substance, excipient and primary container
Draft agreed by QWP and BWP
December 2015
Adopted by CHMP for release for consultation
January 2016
Adopted by CVMP for release for consultation
February 2016
Start of public consultation
13 April 2016
End of consultation (deadline for comments)
13 October 2016
Agreed by BWP
July 2018
Agreed by CAT
September 2018
Agreed by QWP and GMDP IWG
October 2018
Adopted by CHMP for publication
15 November 2018
Adopted by CVMP for publication
6 December 2018
Date for coming into effect
1 October 2019 
This guideline replaces the document Decision trees for the selection of sterilisation methods 
(CPMP/QWP/054/98), which is an annex to the note for guidance on development pharmaceutics 
(CPMP/QWP/155/96); and the document Decision trees for the selection of sterilisation methods 
(EMEA/CVMP/065/99) which is an annex to the note for guidance: Development pharmaceutics for 
veterinary medicinal products (EMEA/CVMP/315/98).
Guideline on the sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 2/25
Keywords
Active substance, Aseptic processing, Container, Decision trees, Excipients, 
Filtration, Finished Dosage form, Sterilisation, Sterilisation assurance level, 
Terminal sterilisation, Post-aseptic processing terminal heat treatment.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 3/25
Guideline on sterilisation of the medicinal product, active 
substance, excipient and primary container
Table of contents
1. Introduction (background) ......................................................................4
2. Scope.......................................................................................................4
3. Legal basis...............................................................................................5
4. General requirements ..............................................................................5
4.1. Requirements for the manufacture of sterile medicinal products and sterile components6
4.1.1. Steam sterilisation ............................................................................................7
4.1.2. Dry heat sterilisation.........................................................................................9
4.1.3. Ionization radiation sterilisation ........................................................................10
4.1.4. Gas sterilisation..............................................................................................11
4.1.5. Sterile filtration ..............................................................................................12
4.1.6. Aseptic processing ..........................................................................................14
4.2. Good manufacturing practice for sterile active substances, sterile excipients and sterile 
containers...............................................................................................................14
4.2.1. Active substances ...........................................................................................15
4.2.2. Excipients ......................................................................................................15
4.2.3. Containers .....................................................................................................15
4.3. Selection of sterilisation method ..........................................................................16
5. Decision trees........................................................................................18
6. Definitions .............................................................................................21
7. References.............................................................................................24
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 4/25
Executive summary
Guidance is provided on the selection of appropriate methods of sterilisation for sterile products. 
Although, terminal sterilisation using a reference condition of the European Pharmacopoeia (Ph. Eur.) 
is the method of choice whenever possible, this guideline provides information on when other terminal 
sterilisation processes, sterilising filtration or aseptic processing, (either alone or when combined with 
an additional post-aseptic processing terminal heat treatment), could be accepted as an alternative.
Guidance is provided on the documentation expected for sterile finished products, sterile active 
substances, sterile excipients and sterile primary containers (referred to as container in this guideline) 
in a new marketing authorisation application or a variation application for a medicinal product, (called 
quality dossier throughout the guideline).
Terminology definitions are included at the end of the document.
1.  Introduction (background)
Sterility is a critical quality attribute for all sterile substances, products and containers. Sterility cannot 
be assured by testing, it needs to be assured by the use of a suitably designed, validated and 
controlled manufacturing process. Sterility is achieved by controlling several factors such as the 
bioburden, the sterilisation procedure, the integrity of the container closure system and in the case of 
aseptic processing, the use of satisfactory aseptic technique. 
Terminal sterilisation is preferred to sterilisation by filtration and/or aseptic processing because it is 
lethal to micro-organisms and a reliable sterility assurance level (SAL) is possible to calculate, validate 
and control, and thus incorporates a safety margin. For sterile filtration followed by aseptic processing, 
this is not applicable as accidental contamination caused by inadequate technique cannot be reliably 
eliminated by monitoring and control. Therefore, terminal sterilisation provides the highest assurance 
of sterility and should be used whenever possible. 
For highly sensitive products, such as most biological products, where terminal sterilisation of the 
finished product is not possible, sterile filtration and/or aseptic processing under validated and 
controlled conditions can be accepted.
Sterile filtration and aseptic processing are closely related and difficult to consider separately, since 
sterile filtration in most cases is followed by at least one aseptic processing step such as filling. In 
order to focus on the most important aspect of filtration and aseptic processing at each section of this 
guideline, only one of the two steps may be mentioned, even if both steps are related.
In addition to those finished products where the formulation itself prohibits the possibility of terminal 
sterilisation, the use of aseptic processing can be accepted in certain situations, even if the formulation 
itself can be terminally sterilised, if other benefits are gained for patients or users of the product. 
These situations are specified below in section 4.3.
Container integrity is discussed in ICH Q8, (adopted for human medicinal products only, nevertheless 
the same principles are also applicable to veterinary medicinal products and containers of sterile 
substances and containers).
2.  Scope
The guideline applies to chemical and biological medicinal products for human and veterinary use but is 
not applicable to immunological veterinary medicinal products.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 5/25
It is acknowledged that the recommendations provided for in this guideline may require some 
adaptation to the specific characteristics of Advanced Therapy Medicinal Products (ATMPs) for human 
use (e.g. difficulties to differentiate between starting material, active substance and finished product in 
some cases, scarcity of starting materials/active substance/finished product (autologous products and 
matched-donor scenario), small volumes of production). The level of documentation that is expected to 
be included in marketing authorisation applications for ATMPs may be adapted provided that this is 
justified under a risk-based approach. For veterinary cell based novel therapies, cross reference is 
made to EMA/CVMP/ADVENT/751229/2016 Questions and Answers on allogenic stem cell-based 
products for veterinary use: specific questions on sterility.
Guidance is provided on the choice of sterilisation method, the development data and manufacturing 
data required to demonstrate the suitability of the selected sterilisation process. The same principles 
(choice of method of sterilisation, development data and manufacturing data) apply to sterile active 
substances, excipients and primary containers. Only the information expected in the quality dossier, 
including information related to Good Manufacturing Practice (GMP) certificates, is described. Not all 
GMP requirements (e.g. environmental monitoring, sterilisation of manufacturing equipment) are 
referenced in the guideline, only those that are considered specifically relevant for the quality dossier. 
The scope of this document includes:

Terminal sterilisation by steam, dry heat and ionising irradiation using the reference conditions 
of Ph. Eur. 5.1.1 “Methods of preparation of sterile products” or other conditions stated in that 
monograph

Sterilisation by filtration and aseptic processing 

Sterilisation by gas 
The concepts in this guideline refer only to absence or removal of bacteria, fungi and bacterial 
endotoxins. The absence, removal or inactivation of viruses, mycoplasma, prions and other 
adventitious agents, which could contaminate a product, are not considered. For virus validation 
reference is made to the Guideline Virus validation studies: the design, contribution and interpretation 
of studies validating the inactivation and removal of viruses, CPMP/BWP/268/95.
3.  Legal basis
This guideline should be read in conjunction with Directive 2001/83/EC on the community code relating 
to medicinal products for human use, Directive 2001/82/EC on medicinal products for veterinary use as 
amended and also the current Ph. Eur.
In addition, this guideline should be read in conjunction with all other relevant directives and 
regulations, and all relevant Commission, (V)ICH and CXMP guidelines, Q&A documents and other 
documents as linked to or published on the EMA website (www.ema.europa.eu).
4.  General requirements
The guideline concerns specific requirements related to sterility, sterilisation processes and aseptic 
processing of sterile products and product components. 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 6/25
4.1.  Requirements for the manufacture of sterile medicinal products and 
sterile components
The choice of sterilisation method or aseptic processing should be justified, see section 4.3 Selection of 
sterilisation method.
All sterilisation processes should be carried out according to the instructions of the Ph. Eur. unless 
justified.
All sterilisation procedures for the finished product, active substance, the excipient(s) or the containers 
and the name and address of the sterilisation site should be stated. A description of the sterilisation 
method and/or aseptic processing, including in-process controls and validation data should be 
provided. 
When parametric release of sterility is proposed, the Guideline on real time release testing (formerly 
Guideline on parametric release), EMA/CHMP/QWP/811210/2009-Rev1 (human products only), the 
Guideline on Parametric release, EMEA/CVMP/QWP/339588/2005 (veterinary products only) and the 
text of Ph. Eur. Chapter 5.1.1 should be taken into account.
The bioburden control criteria should be specified prior to all sterilisation processes. High bioburden 
acceptance criteria should not be justified by the capacity of the sterilisation process or any bioburden 
reducing step before sterilisation. Acceptance criteria for bioburden are discussed under the relevant 
sub-sections of 4.1 below.
The levels of bacterial endotoxins in the finished product can be impacted by the bioburden and 
bacterial endotoxins in the components (i.e. active substance, excipients and containers), and by 
microbiological contaminants introduced during manufacture. To ensure an acceptable level of bacterial 
endotoxins in the finished product, the level of microbiological contaminants of the components should 
be minimal. Acceptance criteria for bioburden and, where relevant, bacterial endotoxins in components 
and bulk solutions should be specified.
All filters used in the manufacture of the finished product that come in contact with the finished 
product, or with any component (substance or intermediate product) incorporated in the finished 
product should be described and the information stated in Table3, section 4.1.5 should be provided in 
the quality dossier. The information should be in line with the requirements stated in Eudralex GMP 
Annex 1. For ATMPs, the Guidelines on Good Manufacturing Practice specific to Advanced Therapy 
Medicinal Products should be followed.
If a secondary container (e.g. secondary pouch for infusion bags or blisters intended to keep the 
outside of the container sterile) is used to provide a specific protection to the medicinal product, the 
packaging process should be described, including a risk assessment, since it may affect the sterility of 
the finished product; for example, trapping moisture between the primary and secondary containers. 
Information should be provided as to when the packaging step is performed (before or after 
sterilisation) and any aseptic techniques employed. The proposed processes should be justified from a 
microbiological perspective. If the use of a secondary container means additional sterilisation of the 
finished product is performed, this should be justified with regard to sterility assurance and any 
potential impact on finished product quality.
Documentation regarding sterilisation and aseptic processing to be included in the quality dossier is 
presented below. The documentation could, for practical reasons, be presented in connection with the 
item which is to be sterilised if a reference to the location of the documents is provided in section 
3.2.P.3.3 or in Part 2 B. The documents may be provided for human products in sections 3.2.S.2 
Manufacture, 3.2.P.2 Pharmaceutical development, 3.2.P.3 Manufacture, 3.2.P.4 Control of excipients, 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 7/25
or 3.2.P.7 Container closure system, or for veterinary products in Part 2 A.4 Development 
pharmaceutics, Part 2 B.1 Manufacturing method, Part 2 C.1 Active substance, Part 2 C.2 Excipients or 
Part 2 C.3 Container closure systems. The documentation should be provided for all sites performing 
sterilisation or aseptic processing, regardless of whether the processes are performed in-house or 
outsourced.
Process parameters such as processing and holding times are assessed and agreed during the 
evaluation of the quality dossier. These may be further reviewed during GMP inspections, which may 
result in changes to the registered dossier being required.
4.1.1.  Steam sterilisation
All steam sterilisation processes require a minimum lethality of F0 ≥ 8 minutes and a minimum process 
hold temperature of 110 °C.
Sterilisation processes of different levels of lethality are presented in Table 1, along with the 
documentation to be included in the quality dossier. The processes in the table are presented with 
decreasing lethality when read from top to bottom, thus the first feasible process should be selected. 
For sterilisation using a reference condition of the Ph. Eur. 5.1.1 (≥121 °C, ≥15 min in all units) 
validation data for the sterilisation cycle is not required to be submitted in the quality dossier.
If used as an additional control to measure the process lethality, F0, should be stated, together with the 
lowest temperature measured by the temperature sensors to determine F0. 
Steam sterilisation performed with finished product temperature below 115 °C during the holding 
phase is an exceptional case and should be scientifically justified and supported by additional data as 
described in Table 1. If temperatures below 110 °C are included (during heat-up and cool-down) in the 
determination of F0, this should be justified.
Information regarding the F0 concept and microbial reduction is provided in Ph. Eur. 5.1.5 Application 
of the F0 concept to steam sterilisation of aqueous preparations.
The bioburden limit should be in line with any pre-sterilisation bioburden reduction process capability 
(e.g. filtration). For aqueous solutions, the limits stated in Table 1 are acceptable for active substances 
and drug product formulations without further justification. Other testing regimes and limits to control 
bioburden at the defined level should be justified.
Moist heat processes with an F0 < 8 min may be suitable as a post-aseptic processing terminal heat 
treatment for formulations that cannot withstand a complete terminal sterilisation cycle. Such 
processes may further ensure a SAL of sterile filtered (or otherwise sterilised) bulk components, which 
have been aseptically filled. Post-aseptic processing terminal heat treatments are also presented in 
Table 1.
It is emphasised that this additional post-aseptic processing terminal heat treatment should not 
compensate for poor aseptic manufacturing practice. The same requirements for the aseptic part of the 
process apply as for finished products manufactured without such an additional post-aseptic processing 
terminal heat treatment. 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 8/25
1
Table 1 Cycles for steam sterilisation and post-aseptic processing terminal heat treatment and corresponding data required in the quality 
2
dossier
Cycle
Type of process
Information in 
dossier*
Bioburden level before steam sterilisation or terminal 
heat treatment
Bioburden
Characterised
Process hold 
temperature
Ph. Eur. 5.1.1 
Reference Cycle
Sterilisation
1, 6
100 CFU/100ml (non-routine)
No
≥ 121 °C for ≥15 
minutes
Overkill cycle
Fo >12 min
Sterilisation
1, 2, 3, 4, 7
100 CFU/100ml (non-routine)
No
≥ 121 °C
Fo > 8 min
Sterilisation
1, 2, 3, 4, 7
100 CFU/100ml (routine)
No
> 115 °C
Fo > 8 min
Sterilisation
1, 2, 3, 5, 7, 8
100 CFU/100ml (routine)
Yes**
> 115 °C
Fo > 8 min
Sterilisation
1, 2, 3, 4, 7
100 CFU/100ml (routine)
Yes
> 110 °C
Fo > 8 min
Sterilisation
1, 2, 3, 5, 7, 8
100 CFU/100ml (routine)
Yes**
> 110 °C
Fo <8 min
Post-aseptic processing 
terminal heat treatment
1, 2, 3, 4, 7, 8
0 CFU/100ml, aseptic filtration and processing prior to 
terminal heat treatment (routine)
Yes***
> 110 °C****
Fo <8 min
Post-aseptic processing 
terminal heat treatment
1 2, 3, 5, 7, 8
0 CFU/100ml, aseptic filtration and  processing prior to 
terminal heat treatment (routine)
Yes***
> 110 °C****
3
* For clarification of the code numbers, see below
4
** In-process control demonstrating acceptable heat resistance of bioburden
5
*** The bioburden prior to the sterilisation step (i.e. filtration) should be characterised for heat resistance
6
**** Temperatures below 110 °C may be used if justified. The requirement for additional documentation for such cycles is evaluated on a case by case basis
7
Clarification of the information to be presented in the quality dossier
8
1: Sterilisation time, temperature profile
9
2: Sterilisation method (for instance saturated steam cycle, air/steam-overpressure cycle, vacuum phase) description including SAL
10
3: Validation of F0Phys and F0Bio
11
4: Biological indicator with a D121 ≥ 1.5 minutes used in the validation
12
5: Biological indicator with a D121 < 1.5 minutes used in the validation
13
6: No validation data requested in the dossier, only a confirmation that validation has been performed.
14
7: Validation data to be provided in the dossier is presented below
15
8: Additional validation data to be provided in the dossier is presented below
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 9/25
Validation data to be provided in the quality dossier for all steam sterilisation processes that 
do not fulfil the requirements of Ph. Eur. 5.1.1 standard process (required information 7 in 
Table 1):

Load mapping of the chamber and load mapping distribution of the items in the chamber (including 
the slowest to heat locations); summary or confirmation of performance.

Physical and biological cycle effect confirmation summary of at least three sterilisation runs 
demonstrating an SAL ≤10-6, as described in Ph. Eur. 5.1.1 ensuring:

Demonstration that the sterilisation load in the steriliser chamber achieves the specified cycle 
parameters, including time, temperature, pressure and F0, if applicable; 

Acceptable temperature differences between temperature sensors in the load;

Acceptable F0 variability within the load;

Relationship between physical and biological validation.
 
For the biological validation, a biological indicator as described in Ph. Eur. chapter 5.1.2 Biological 
indicators and related microbial preparations used in the manufacture of sterile products with a 
D121-value of ≥1.5 minutes should be used.
 
The SAL should be determined, its microbiological basis should be justified and details of 
calculations provided in the quality dossier. Preferably it should be calculated from the maximum 
bioburden per container and the D-value of the biological indicator used in the validation.
Additional validation data to be provided in the quality dossier for low energy steam 
processes or where a bio-indicator with a D121-value of <1.5 minutes is used in the 
validation of the sterilisation process (required information 8 in Table 1):
The following additional data should be provided:

A justification for the start point of the sterilisation phase, that is the temperature when the 
temperature sensors record the F0 from the start to end of the process;

Biological indicators with suitable resistance at the actual temperature range as described in Ph. 
Eur. 5.1.2 should be included in the validation to demonstrate sensitivity to the process.
More detailed validation data is requested to ensure that the proposed sterilisation process is suitable 
for low temperature processes and for processes using biological indicators of low heat resistance 
because:

The change in lethal effect in relation to the process temperature may not be log linear at 
lower sterilisation temperatures.

The SAL demonstrated in the validation of a sterilisation process is dependent on the heat 
resistance of the biological indicator used in the validation of the process. When a biological 
indicator of low D-value is used in the validation of the sterilisation process, the SAL 
demonstrated becomes numerically higher, but does not provide as high a safety margin as 
where a more resistant biological indicator is used. The SAL should always be established in 
relation to a D-value that is higher than that of the normal bioburden at routine production.
4.1.2.  Dry heat sterilisation
Time and temperature of the sterilisation cycle and a bioburden limit should always be stated.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 10/25
For sterilisation using a reference condition of the Ph. Eur. 5.1.1 (a minimum of 160 °C for at least 2 
h), the validation data for the sterilisation cycle is not required to be submitted in the quality dossier. 
For sterilisation cycles with time and/or temperature lower than the reference conditions of the Ph. 
Eur., physical and biological validation of the sterilisation cycle should be provided to demonstrate an 
SAL of ≤10-6, as described in Ph. Eur. 5.1.1. The SAL of such a sterilisation process should be 
calculated from the maximum bioburden per container.
Where required, sufficient validation data should be submitted to demonstrate that an SAL of ≤10-6 is 
obtained for all containers. The data submitted should include at least, but is not limited to:

Load mapping of the chamber and load mapping distribution of the items in the chamber (including 
the slowest to heat locations) – summary or confirmation of performance;

Physical and biological cycle effect confirmation summary of at least three sterilisation runs 
ensuring:

Demonstration that the sterilisation load in the steriliser chamber achieves the specified cycle 
parameters, including time, temperature, and, lethality;

Acceptable temperature differences between temperature sensors in the load;

Acceptable lethality variability within the load;

Relationship between physical and biological validation.
For the biological validation, a biological indicator as described in Ph. Eur. chapter 5.1.2 should be 
used.
A maximum bioburden limit of 100 CFU/100 g or 100 CFU/100 ml would be acceptable for parenteral 
finished product formulations without further justification. For active substances and finished products 
that are not used for parenteral administration, a maximum total bioburden limit of 10 CFU/g or 10 
CFU/ml is acceptable without further risk based justification. Other testing regimes and limits to control 
bioburden at the defined level should be justified. A justified bioburden limit should also be established 
for empty containers.
Dry heat at temperatures of greater than 220 °C for a validated time is frequently used for both 
sterilisation and depyrogenation of glassware and other heat-resistant container materials e.g. 
aluminium crimps. In this case, demonstration of a 3 log reduction in heat-resistant endotoxins can be 
used as validation criteria.
4.1.3.  Ionization radiation sterilisation
For this method of sterilisation, the reference absorbed dose is ≥25 kGy. Other doses may be used to 
achieve an SAL ≤10−6, if justified and validated.
Data as requested in Note for Guidance “The use of Ionization Radiation in the Manufacture for 
Medicinal Products” and in compliance with Ph. Eur. chapter 5.1.1 should be provided. Relevant 
guidance in establishing the radiation dose other than 25 kGy is available in ISO standard 11137.
Where any requirements in ISO 11137 are in contradiction to requirements stated in any Note for 
Guidance issued by the EMA or Ph. Eur. monograph, the requirements of the Ph. Eur. and the Note for 
guidance apply.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 11/25
4.1.4.  Gas sterilisation
4.1.4.1 General considerations
Generally, gas sterilisation is only acceptable if no other method of sterilisation is possible. Gas 
sterilisation provides sterilisation of the surface of materials. It is mainly employed for sterilising 
packaging materials and equipment, and has therefore only been included in the decision tree for 
containers. To ensure adequate sterility, sufficient penetration by gas and moisture is essential. This 
should be followed by a purging process to ensure that any residues of gas or related transformation 
by-products are below concentrations that could give rise to toxic effects during use of the finished 
product. The effectiveness of the purging process should be demonstrated.
Gas sterilisation of porous compounds, such as dry powders, is not acceptable unless other methods of 
sterilisation are not feasible and its use is scientifically justified. Prior to the gas sterilisation, the active 
substance or excipient should be sterile filtered and crystallised under aseptic conditions to minimise 
bioburden and entrapment of micro-organisms within the crystals. Convincing evidence should be 
provided demonstrating that the material to be sterilised is not susceptible to compression preventing 
gas and moisture penetration during sterilisation.
A description of the apparatus, quantitative data on gas(es) to be used, the bioburden prior to 
sterilisation, the time of exposure to the gas, the temperature and humidity prior to and during each 
step of the sterilisation cycle, and, if applicable, the conditions for the removal of any toxic gas 
residues should be provided. Humidity used for the preconditioning and/or conditioning of the material 
to be sterilised shall be generated by clean steam. These conditions should be monitored by 
appropriate in-process controls with justified acceptance criteria. The process should be developed and 
validated in compliance with Ph. Eur. 5.1.1 and 5.1.2. A risk assessment with regards to residual toxic 
impurities should be conducted and a control strategy should be provided where applicable. The 
requirements should be in accordance with the requirements of ICH M7 “Assessment and control of 
DNA reactive (mutagenic) impurities in pharmaceuticals to limit potential carcinogenic risk”. Even if the 
relevant product is outside the scope of that guideline, its limits for highly toxic impurities could be 
applied.
Results of the process validation should demonstrate an SAL of ≤10-6.
The effectiveness of the process should be routinely checked for every batch confirming that the 
process parameters and biological indicators are all within their acceptance criteria and by sterility 
testing. Parametric release is not acceptable for gas sterilisation (according to Ph. Eur. chapter 5.1.1).
4.1.4.2 Ethylene oxide sterilisation
Ethylene oxide (ETO) sterilisation processes should be developed and validated in compliance with Ph. 
Eur. 5.1.1 and 5.1.2. Relevant guidance in establishing the sterilisation process cycle parameters and 
validation is available in ISO standard 11135. 
ETO is a gas which is highly toxic. ETO sterilisation is generally only acceptable if no other method of 
sterilisation is possible. The risk assessment should consider the residual known genotoxic impurities 
(such as ETO and halogenated ethylenehydrines). This should be evaluated in accordance with the 
requirements of ICH M7 “Assessment and control of DNA reactive (mutagenic) impurities in 
pharmaceuticals to limit potential carcinogenic risk”, unless the relevant product is outside the scope of 
that guideline. For products outside the scope of ICH M7, the applicant should apply limits for highly 
toxic impurities in accordance with ICH M7, or the acceptance criteria stated in Table 2, whichever is 
most appropriate. 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 12/25
For empty containers intended to be filled with aqueous products, (e.g. prefilled syringes), the need to 
justify the use of ETO in the sterilisation of the container prior to filling can be waived, as the 
degradation kinetics of ETO in an aqueous medium have been sufficiently demonstrated. However, the 
levels of toxic residues (ETO and halogenated ethylenehydrines) in the finished product need to fulfil 
the requirements of ICH M7, or the limits stated in Table 2 below, as applicable.
Table 2 Limits for toxic gas residues from ethylene sterilisation where the ICH M7 limits do 
not apply
Material
Ethylene 
oxide
Ethylene chlorhydrin (or any other 
halogenated ethylenehydrine)
Raw materials
1 µg/g
50 µg/g
Finished product (when used on 
the finished product)
1 µg/g
50 µg/g
Container (based on simulated 
use)
1 µg/ml
50 µg/ml
4.1.5.  Sterile filtration
The filter data to be provided in the quality dossier is summarised in Table 3.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 13/25
Table 3 Filter data to be provided in the quality dossier for filters in contact with the drug 
product or components of the drug product
Filter
Parameter
Non-
sterilising1
Sterilising1
Comment
General information on filter
Type of material, 
nominal pore size
X
X
Number of filters
X
X
Filter area
-
X
Filter integrity test
-
X
Principle of the test, details on when the tests are 
performed, solution(s) used in the test and 
acceptance criteria before and after filtration 
should be described.
Filter validation
Solution 
used
Comment
Potential sorption of 
solution components 
to filter
X
X
Product
Solution 
Compatibility
X
X
Product
Worst case conditions with regards 
to for instance sterilisation process, 
contact time, filtration time, 
pressure, filtered volume.
Filter retention 
capacity
-
X
Product 2 
Minimum 107 CFU/cm2 using a 
justified indicator organism and the 
actual solution.
Filter integrity test 
limits
-
X
Product 3 
Extractable and 
leachable 
substances from the 
filter
X
X
Product 4
Justified surrogate solution may be 
used.
1 As defined in GMP, Annex 1
2 Validation of filter retention capacity may be combined with solution compatibility. If the product 
solution affects the indicator organisms negatively, it should be neutralised before adding the 
organisms. For validation, a suitable challenge microorganism representing the worst-case challenge to 
the filter should be used.
3 If the test is performed using a different solution in routine manufacture (for instance water for 
injections), the limits should be established in this solution.
4 Data on leachables is relevant only if the extractables data indicate that toxic components may leach 
into the solution to be filtered.
The integrity of the sterilised filter should be verified by testing before use unless specifically justified 
and validated, and should be verified by on line testing immediately after use. Nominal pore sizes of 
0.22 µm or less are acceptable without further justification, in accordance with Ph. Eur.
For routine commercial manufacturing, bioburden testing should be performed on the bulk solution 
immediately before sterile filtration.
In most situations, a limit of NMT 10 CFU/100 ml (TAMC) would be acceptable for bioburden testing. If 
a pre-filter is added as a precaution only and not because the unfiltered bulk solution has a higher 
bioburden, this limit is applicable also before the pre-filter and is strongly recommended from a GMP 
point of view. A bioburden limit of higher than 10 CFU/100 ml before pre-filtration may be acceptable if 
this is due to starting material known to have inherent microbial contamination. In such cases, it 
should be demonstrated that the first filter is capable of achieving a bioburden of NMT 10 CFU/100 ml 
prior to the last filtration. Bioburden should be tested in a bulk sample of 100 ml in order to ensure the 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 14/25
sensitivity of the method. Other testing regimes to control bioburden at the defined level should be 
justified.
The maximum time between the start of bulk solution preparation and sterile filtration should be 
stated, minimised and appropriately supported by data. Filtration times longer than 24 hours should be 
justified.
If a sterile filtered bulk solution is not filled into the final product containers within 24 hours, the sterile 
filtration should, unless justified, be repeated immediately before filling. An additional bioburden test 
should be performed before any further bioburden reduction step after the holding time. The holding 
time should be adequately justified.
4.1.6.  Aseptic processing
Aseptic processing is not considered to be a sterilisation process but concerns the usage of 
technologies to process sterile components avoiding addition of microbiological contaminants, e.g. use 
of an isolator or Restricted Access Barrier System (RABS).
For aseptic processing, information on the bulk holding time before filling and on the filling time should 
be stated and appropriately supported by data. The times should be minimised. The grounds for 
holding and filling times longer than 24 hours should be justified and supported by a risk assessment. 
It should be verified that the results of the media simulations support the proposed holding and 
processing times. The actual results of media simulations fall within the field of GMP and need not be 
presented routinely, but may be requested by the competent authorities in certain circumstances since 
such data are important to justify proposed holding and filling times.
Sterile containers should be used for aseptically treated active substances, excipients and finished 
products.
Where blow-fill-seal technology is used for aseptically treated products, a summary of the validation 
data should be provided to confirm that the container produced is sterile. The validation should, using 
a biological indicator with a suitable resistance, demonstrate a SAL of ≤10-6 for the surface of the 
container. The bioburden of the material(s) used for the manufacture of the blow-fill-seal container 
should be controlled. The limit should be justified in relation to the lethality of the validated blow-fill-
seal process. The bioburden limit should also include a safety margin as a precaution for any possible 
bioburden enclosed within the material.
The majority of ATMPs cannot be terminally sterilised. In such cases, the manufacturing process should 
be conducted aseptically. Further details on aseptic manufacturing for ATMPs can be found in the 
Guidelines on Good Manufacturing Practice for Advanced Therapy Medicinal Products.
4.2.  Good manufacturing practice for sterile active substances, sterile 
excipients and sterile containers
Volume 4 of "The rules governing medicinal products in the European Union" contains guidance for the 
interpretation of the principles and guidelines of good manufacturing practices for medicinal products 
for human and veterinary use laid down in Commission Directives 91/356/EEC, as amended by 
Directive 2003/94/EC, and 91/412/EEC respectively. For Advanced Therapy Medicinal Products, the 
Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products should be 
followed.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 15/25
4.2.1.  Active substances
The basic GMP requirements for active substances used as starting materials (European Union (EU) 
GMP guide part II) apply to the manufacture of sterile active substances up to the point immediately 
prior to the active substance being rendered sterile. The sterilisation and aseptic processing of sterile 
active substances are not covered by EU GMP Part II but should be performed in accordance with the 
principles and guidelines of GMP as laid out in the relevant EU Directive and interpreted in the GMP 
Guide including its Annex 1. 
The sterilisation and aseptic processing of active substances is considered to be a step in the 
manufacture of the medicinal product. This implies that for any active substance manufacturer who 
performs sterilisation and subsequent aseptic handling of the active substance, a valid manufacturing 
authorisation or GMP certificate from an EEA authority or from an authority of countries where mutual 
recognition or other Community arrangements apply has to be submitted.
The same GMP and data requirements also apply to sterile active substances supported by a Certificate 
of Suitability issued by the European Directorate for the Quality of Medicines & HealthCare (EDQM) or 
described in an Active Substance Master File (ASMF).
4.2.2.  Excipients
All the excipient sterilisation sites should be stated by name and address in the dossier.
For excipients required to be sterile (i.e. those subsequently used in an aseptic manufacturing 
process), the site where sterilisation of the excipients takes place may not have undergone inspection 
by an EU authority and consequently may not hold an EU GMP certificate in relation to this activity. 
Nevertheless the sterilisation of an excipient is a critical process and the sterility of the excipient is a 
critical quality attribute to ensure the sterility of the finished product. When a GMP certificate is not 
available, a statement should be provided confirming that the finished product manufacturer has 
evaluated all the manufacturers of sterile excipients with regards to their quality system related to the 
sterilisation of the excipient. For products for human use this evaluation should be conducted in line 
with the (GMP) Guidelines of 19 March 2015 on the formalised risk assessment for ascertaining the 
appropriate good manufacturing practice for excipients of medicinal products for human use by taking 
into account the specific requirements of Annex 1 of EU GMP-Guidelines. 
4.2.3.  Containers
For containers required to be sterile (i.e. those subsequently used in an aseptic manufacturing 
process), the site where sterilisation of the containers takes place may not have undergone inspection 
by an EU authority and consequently may not hold an EU GMP certificate in relation to this activity1. 
When a GMP certificate is not available, certification that the sterilisation has been conducted and 
validated in accordance with the following ISO standards would be considered sufficient to provide an 
acceptable level of sterility assurance for the empty container:
1.
I.S. EN ISO 20857 Sterilization of Health Care Products - dry Heat - Requirements for the 
Development, Validation and Routine Control of a Sterilization Process for Medical Devices;
2.
I.S. EN ISO 11135 Sterilization of Health-care Products - Ethylene Oxide - Requirements for 
the Development, Validation and Routine Control of a Sterilization Process for Medical Devices;
1 Sites located in the EU which perform sterilisation of primary containers only are not required to hold a 
Manufacturer’s/Importer’s Authorisation (MIA). Sites located in the EU, which carry out sterilisation of medicinal products, 
are required to hold a MIA in relation to these activities.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 16/25
3.
I.S. EN ISO 17665-1 Sterilization of Health Care Products - Moist Heat - Part 1: Requirements 
for the Development, Validation and Routine Control of a Sterilization Process for Medical 
Devices, and, ISO/TS 17665-2 Sterilization of health care products -- Moist heat -- Part 2: 
Guidance on the application of ISO 17665-1;
4.
I.S. EN ISO 11137-1 Sterilization of Health Care Products - Radiation - Part 1: Requirements 
for Development, Validation and Routine Control of a Sterilization Process for Medical Devices;
5.
I.S. EN ISO 11137-2 Sterilization of Health Care Products - Radiation - Part 2: Establishing the 
Sterilization Dose;
6.
I.S. EN ISO 11137-3 Sterilization of Health Care Products - Radiation - Part 3: Guidance on 
Dosimetric Aspects.
It is the responsibility of the manufacturer of the medicinal product, to ensure the quality, including 
sterility assurance, of containers. The site where QP certification of the finished product takes place, 
and other manufacturing sites which are responsible for outsourcing this sterilisation activity, should 
have access to the necessary information to demonstrate the ongoing qualification status of suppliers 
of this sterilisation service. This may be checked during inspections of the manufacturer of the finished 
product. The Competent Authorities may also decide, based on risk, to carry out their own inspections 
at the sites where such sterilisation activities take place.
Quality Dossier requirements
The following details regarding the sterilisation of the container components should be included in the 
quality dossier:
1.
The sterilisation method and sterilisation cycle;
2.
Validation of the sterilisation cycle if the sterilisation cycle does not use the reference 
conditions stated in the Ph. Eur.;
3.
The name and address of the site of sterilisation and, where available*, details of GMP 
certification of the site. 
*Where the container component is a CE-marked Class Is sterile device (e.g. sterile syringe), a 
declaration from the device manufacturer that the component is a Class Is sterile device, together with 
a copy of the certificate of conformity from the Notified Body will suffice. In the absence of a GMP 
certificate or declaration that the component is a CE-marked Class Is medical device, confirmation by 
finished product manufacturer that the sterilisation process has been conducted and validated in 
accordance with the relevant ISO standards should be provided.
4.3.  Selection of sterilisation method
Finished products intended to be sterile should be terminally sterilised in their final container whenever 
possible, as clearly stated in the Ph. Eur., general chapter 5.1.1. Similarly, active substances, 
excipients and containers when required to be sterile should be packed before they are sterilised 
whenever possible. When terminal sterilisation by heat is not possible, the application of an alternative 
method of terminal sterilisation, sterilising filtration and/or aseptic processing may be considered. It is 
recognised that terminal sterilisation processes utilising conditions other than the Ph. Eur. reference 
conditions may be developed to provide satisfactory SALs and such alternative processes may be 
acceptable when properly designed, validated and controlled.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 17/25
If a sterilisation process using principles other than those described in the Ph. Eur. (steam, dry heat, 
ionising radiation, gas sterilisation and sterilising filtration) is intended to be used for the sterilisation 
of an active substance, excipient, container or finished product, the applicant may consider seeking 
scientific advice regarding the acceptability of the method and the documentation required.
During the manufacturer’s evaluation of whether a terminal sterilisation cycle is possible, substantial 
efforts should be made to enable terminal sterilisation. If the active substance or another component 
of the finished product is shown to degrade significantly or an impurity limit is exceeded during shelf-
life under even the least stressful terminal sterilisation conditions, the efforts made to develop a 
formulation and container capable of undergoing terminal sterilisation should be presented in the 
development section. Such efforts could be selection of optimal pH, choice of excipients (qualitative 
and quantitative), container, optimisation of sterilisation method and manufacturing conditions.
In case of medicinal products containing highly sensitive active substances, (e.g. proteins or other heat 
labile biological substance), where it is well known that terminal sterilisation is not possible, a 
justification based on a scientific rationale is generally acceptable and further justification of the choice 
of aseptic processing discussed later in section 4.3 may not be needed.
The principles for the choice of sterilisation process for finished products and containers are presented 
in the form of decision trees in section 5 of this guideline. The principles of the decision trees may also 
be applied for the sterilisation of active substances and excipients. 
For finished products where terminal sterilisation is not possible and aseptic processing is proposed, 
the decision trees should be applied to individual components or mixtures of components in the 
formulation. An impact on the shelf-life or storage conditions caused by a terminal sterilisation process 
is not in itself a reason to exclude terminal sterilisation, unless the new storage condition or shelf-life 
would cause significant problems for the user.
Terminal sterilisation should not be ruled out purely on the basis of an increase in degradation 
products above the qualification thresholds in ICH Q3A/VICHGL10 (active substances), ICH Q3B/ VICH 
GL11 (finished products) or the impurity limits in ICH M7 for products in the scope of that guideline 
without additional justification. If impurities are either metabolites or are generated at levels already 
qualified, then terminal sterilisation is still considered feasible. However, if the degradation products 
are not qualified at the level at which they occur, then sterile filtration and aseptic processing may be 
selected. For medicinal products for human use impurities which occur above the identification 
threshold should be specified in the finished product specification.
The risk induced by the degradation should be balanced by the risk induced with an aseptic 
manufacturing method, also taking in account the posology of the finished product and the nature of 
the degradation products. Attempts to find terminal sterilisation conditions adjusted to give acceptable 
impurity levels based on degradation mechanisms of the active substance and the actual bioburden 
should be described in the quality dossier. 
In certain cases, as described in the bullet points below, the use of aseptic processing may be 
accepted, even if the formulation itself can be terminally sterilised. The approach should be clearly 
documented, explained and scientifically justified. Such cases could be justified by:

User benefit provided by a container that cannot be terminally sterilised such as:

Eye drop containers enabling administration of single drops to the eye;

Containers enabling non parenteral multi-dose preservative free medicinal products for human 
use;
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 18/25

Enhanced ease of administration;

Safer handling of toxic products, for instance plastic vials instead of glass vials for cytotoxic 
medicinal products.
The choice to use a heat-labile container cannot in itself be the sole reason for not applying a 
terminal sterilisation process and alternative materials should be investigated. Thus, a discussion 
regarding the efforts made to develop a container that may be terminally sterilised should be 
included.

Enabling as long a shelf-life as possible for radiopharmaceutical medicinal products with a shelf-life 
of less than one week.
The acceptability of aseptic processing should be based on the application of the decision tree and a 
risk assessment. The bullet points below are not intended to be used to justify aseptic processing as 
such, but are only intended to provide guidance on issues that are considered when evaluating the 
acceptability of a sterilisation or aseptic processing. Considerations include (but are not limited to):

Evidence that the proposed container with enhanced user benefits is fit for purpose;

Stability of the active substance, the degradation mechanism(s) and the toxicity of impurities 
formed during the sterilisation process;

The volume to be administered per dose.
In conclusion, the justification for the chosen sterilisation or aseptic processing should include a 
thorough benefit risk evaluation and it should be demonstrated that suitable development efforts have 
been made.
For advanced therapy medicinal products, the microbiological quality of all components, process 
equipment and the aseptic techniques of the manufacturing processes are of utmost importance when 
the finished product cannot be sterilised. For those medicinal products that cannot be sterilised, such 
as cell based medicinal products, a detailed risk assessment with regards to microbial contamination 
should be provided. A risk based approach is already foreseen for these ATMP (see Guideline on the 
risk-based approach according to annex I, part IV of Directive 2001/83/EC applied to Advanced 
therapy medicinal products, EMA/CAT/CPWP/686637/2011).
5.  Decision trees
The decision trees in Figures 1 and 2 are intended to assist in the selection of the optimal sterilisation 
method taking into account the various issues to be considered. When moving down the decision trees, 
the methods generally show a decreasing assurance of sterility and therefore, the first feasible option 
should normally be chosen.* The decision trees have been elaborated primarily for finished products 
containing chemical active substances, but may be applicable also to other types of products (including 
active substance and excipients). Figure 3 provides the corresponding information for empty 
containers. The decision tree is not applicable to sterile empty containers that are CE marked medical 
devices. In the case of biological products, an alternative approach may be appropriate.
*While sterilisation by heat and sterilisation by ionising irradiation provide the same assurance of 
sterility, sterilisation by heat has lower risk (e.g. radiolysis impurities) and is more easily controlled 
than sterilisation by ionising irradiation. For these reasons, heat is given priority over ionising 
irradiation in the decision trees.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 19/25
Figure 1 Decision tree for sterilisation choices for aqueous products
Figure 2 Decision tree for sterilisation choices for dry powder products, non-aqueous liquid 
or semi-solid products
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 20/25
Figure 3 Decision tree for sterilisation choices for containers
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 21/25
6.  Definitions
Aseptic processing
A process performed maintaining the sterility of a 
product that is assembled from components, each 
of which has been sterilised by steam, dry heat, 
ionizing radiation, gas or sterile filtration. This is 
achieved by using conditions and facilities 
designed to prevent microbiological 
contaminants.
Bioburden
The total number of micro-organisms associated 
with a specific item prior to any sterilisation or 
bioburden reduction step.
Biological indicator
Biological indicators are test systems containing 
viable microorganisms (usually spores of 
bacteria) that provide a defined challenge to 
verify the required effectiveness of a specified 
sterilisation process.
Colony Forming Unit (CFU)
A microbiological term that describes the 
formation of a single macroscopic colony after the 
introduction of one or more micro-organisms to 
microbiological growth media. One colony forming 
unit is expressed as 1 CFU.
Critical Quality Attribute
A physical, chemical, biological or microbiological 
property or characteristic that should be within an 
appropriate acceptance criteria, range, or 
distribution to ensure the desired product quality
Depyrogenation
A process used to destroy or remove pyrogens 
(e.g. endotoxins).
D-value (decimal reduction value)
The value of a parameter of sterilisation (duration 
or absorbed dose) required to reduce the number 
of viable organisms to 10 per cent of the original 
number. It is only of significance under precisely 
defined experimental conditions.
D121 is the D-value of the relevant spores at 121 
C.
F0 value
The F0 value of a saturated steam sterilisation 
process is the lethality expressed in terms of the 
equivalent time in minutes at a temperature of 
121 °C delivered by the process to the load in its 
container with reference to micro-organisms 
possessing a theoretical Z-value of 10.
Filling time
The time used to fill a bulk product into 
containers until the container is closed or, in the 
case of a product which is lyophilized after the 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 22/25
filling, until the lyophilisation chamber is closed.
Holding time
The time between two process steps.
Immunological veterinary medicinal product
A veterinary medicinal product administered to 
animals in order to produce active or passive 
immunity or to diagnose the state of immunity.
Lethal (process)
A process that kills the microorganisms 
exponentially.
Overkill sterilisation
A process with a lethality of F0BIO > 12 minutes.
For example a process that provides at least a 12 
log reduction of biological indicator micro-
organisms having a minimum D value of 1 
minute.  
Ph. Eur. sterilisation reference conditions
The reference conditions for sterilisation specified 
in Ph. Eur. 5.1.1, i.e. terminal steam sterilisation 
at ≥121 °C for 15 min, terminal dry heat 
sterilisation at ≥160 °C for ≥2 h or terminal 
ionising radiation of 25 kGy.
Post-aseptic processing terminal heat treatment
A terminal moist heat process employed after 
aseptic processing which has been demonstrated 
to provide a SAL ≤10-6, but where the 
requirements of steam sterilisation (for example, 
F0≥8 min) are not fulfilled.
SAL
Sterility Assurance Level. The SAL for a given 
sterilisation process is expressed as the 
probability of micro-organisms surviving in a 
product item after exposure to the process. An 
SAL of 10-6, for example, denotes a probability of 
not more than 1 non-sterile item in 1 × 106 
sterilised items of the final product. 
Slowest to heat locations
Location in the load that remains coldest or where 
the temperature is raising slowest during the 
sterilisation process.
It could, in a figurative sense, also be used for 
other sterilisation methods for the location in the 
load achieving the lowest level of sterilising 
energy.
Steam sterilisation
Reference is made to the description in Ph. Eur. 
5.1.1.
Sterilisation
A suitably designed, validated and controlled 
process that inactivates or removes viable micro-
organisms in a product until sterility is obtained.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 23/25
Sterility
Sterility is the absence of viable microorganisms, 
as defined by a sterility assurance level equal to 
or less than 10−6.
The inactivation of microorganisms by physical or 
chemical means follows an exponential law; thus 
there is always a finite statistical probability that 
a micro-organism may survive the sterilising 
process. For a given process, the probability of 
survival is determined by the number, types and 
resistance of the microorganisms present and by 
the environment in which the organisms exist 
during treatment. 
TAMC
Total aerobic microbial count: The total aerobic 
microbial count (TAMC) is considered to be equal 
to the number of CFU found using casein soya 
bean digest agar.
Terminal process
A process where a finished product is processed 
in its primary container, for example terminal 
sterilisation or post-aseptic processing terminal 
heat treatment.
Validation
Establishing documented evidence that provides a 
high degree of assurance that a specific process 
will consistently produce a product meeting its 
predetermined specifications and quality 
attributes.
Worst case
A set of conditions encompassing upper and lower 
processing limits and circumstances, including 
those within standard operating procedures, that 
pose the greatest chance of process or product 
failure (when compared to ideal conditions). Such 
conditions do not necessarily induce product or 
process failure.
z-value
The z-value is the change in temperature 
required to alter the D-value by a factor of 10.
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 24/25
7.  References
Decision trees for the selection of sterilisation methods, CPMP/QWP/054/98;
Note for Guidance: Development Pharmaceutics for veterinary medicinal products: Decision tree for 
the selection of sterilisation methods, EMEA/CVMP/065/99;
Note for guidance on manufacture of the finished dosage form, CPMP/QWP/486/95;
Note for Guidance: Manufacture of the finished dosage form, EMEA/CVMP/126/95;
ICH guideline Q8 (R2) on pharmaceutical development, EMA/CHMP/ICH/167058/2004; 
European Pharmacopoeia general chapter 5.1.1 ‘Methods of preparation of sterile products’;
Note for Guidance: Virus validation studies: the design, contribution and interpretation of studies 
validating the inactivation and removal of viruses, EMA/CPMP/BWP/268/95;
Directive 2001/83/EC of the European Parliament and of the Council of 6 November 2001 on the 
Community code relating to medicinal products for human use, as amended;
Directive 2001/82/EC of the European Parliament and of the Council of 6 November 2001 on the 
Community code relating to veterinary medicinal products, as amended;
Guideline on real time release testing (formerly Guideline on parametric release), 
EMA/CHMP/QWP/811210/2009-Rev1;
Guideline on Parametric release, EMEA/CVMP/QWP/339588/2005;
EudraLex - Volume 4 Good manufacturing practice (GMP) Guidelines;
European Pharmacopoeia general chapter 5.1.5 ‘Application of the F0 concept to steam sterilisation of 
aqueous preparations’;
European Pharmacopoeia general chapter 5.1.2 ‘Biological indicators and related microbial preparations 
used in the manufacture of sterile products’;
NfG on The use of Ionisation Radiation in the Manufacture of Medicinal products 3AQ4A;
EN/ISO 11137, Sterilisation of health care products – Radiation;
ICH guideline M7 on assessment and control of DNA reactive (mutagenic) impurities in pharmaceuticals 
to limit potential carcinogenic risk (EMA/CHMP/ICH/83812/2013);
European Pharmacopoeia general chapter 5.1.7 ‘Viral Safety’
Human cell-based medicinal products, EMEA/CHMP/410869/2006
Questions and Answers on allogenic stem cell-based products for veterinary use: specific questions on 
sterility EMA/CVMP/ADVENT/751229/2016
Guideline on the quality, non-clinical and clinical aspects of gene therapy medicinal products, 
EMA/CAT/80183/2014
I.S. EN ISO 20857 Sterilization of health care products - dry Heat - Requirements for the development, 
validation and routine control of a sterilization process for medical devices 
I.S. EN ISO 11135 Sterilization of health-care products - Ethylene Oxide - Requirements for the 
development, validation and routine control of a sterilization process for medical devices I.S. EN ISO 
Guideline on sterilisation of the medicinal product, active substance, excipient and 
primary container 
EMA/CHMP/CVMP/QWP/850374/2015
Page 25/25
17665-1 Sterilization of health care products - Moist heat - Part 1: Requirements for the development, 
validation and routine control of a sterilization process for medical devices  
ISO/TS 17665-2 Sterilization of health care products -- Moist heat -- Part 2: Guidance on the 
application of ISO 17665-1
I.S. EN ISO 11137-1 Sterilization of health care products - Radiation - Part 1: Requirements for 
development, validation and routine control of a sterilization process for medical devices 
I.S. EN ISO 11137-2 Sterilization of health care products - Radiation - Part 2: Establishing the 
sterilization dose 
I.S. EN ISO 11137-3 Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric 
aspects of development, validation and routine control
ICH Q3A (R2) Impurities in new drug substances, CPMP/ICH/2737/99 
ICH Q3B (R2) Impurities in New Drug Products, CPMP/ICH/2738/99;
VICH GL10 Impurities in new veterinary drug substances, CVMP/VICH/837/99 Rev.1
VICH GL11 Guideline on impurities in new veterinary medicinal products, EMEA/CVMP/VICH/838/99 
Rev.1.
Guideline on the risk-based approach according to annex I, part IV of Directive 2001/83/EC applied to 
Advanced therapy medicinal products, EMA/CAT/CPWP/686637/2011).